Download Print this page

Specification; Control Panel - Sealey G2000I.V2 Instructions Manual

Inverter generator 2000w 230v 4-stroke engine

Advertisement

2. IntroDuctIon
digital inverter technology provides pure sine wave electric power suitable for use with sensitive electrical equipment. lightweight, easily
lifted and fully portable. Eco mode set up allowing the generator to run quieter(60dB@7mtr.), increase fuel efficiency (4ltr. fuel tank will last
6hrs.) and reduce emissions. features light recoil start, fuel gauge, auto voltage adjuster, low oil alarm and electric circuit protector. fitted
with two 230 V Ac sockets and 12V dc 8.3A port.

3. specIfIcatIon

model no .................................................................... G2000i
motor Power ..................................................................... 3hp
motor type .................................................... 4_Stroke Petrol
fuel ........................................................... unleaded 95 ron
output ..................................................... 230V-50Hz/12V dc
current rating .................................................................8.3A
continuous Power rating............................................1600W
maximum Power rating ..............................................2000W
fuel tank capacity ............................................................ 4ltr
maximum running time ....................................................6hr
noise rating ..................................................................95dB
dry Weight .................................................................. 21.5kg
dimensions (WxdxH) ..................................480x285x390mm

4. control panel

1. oil Warning light
2. Ac Pilot light
3. overload indicator light
4. Economy Control Switch
5. engine switch
6. fuel switch
7. Ground earth terminal
8. choke
9. Ac socket
10. dc socket
11. dc Protector
5. controls
5.1.
engine switch
"stoP" ignition circuit is switched off. the engine will not run.
"on" ignition circuit is switched on. the engine can run.
5.2.
oil Warning light (yellow)
if the oil level falls below the lower level, the oil warning light will come on and the engine will stop automatically. the engine will not
start again until the oil is filled up.
If the engine stalls or does not start, press the engine switch to "ON" and then pull the recoil starter, it the oil warning light flickers
for a few seconds, there is insufficient oil, add oil to restart.
5.3.
overload Indicator light (red)
the overload indicator light comes on when an overload of a connected electrical device is detected, the inverter control unit
overheats, or the Ac output voltage rises. then, the Ac protector will trip, stopping power generation in order to protect the
generator and any connected electrical devices. the Ac pilot light (Green) will go off and the overload indicator light (red) will stay
on, the engine will continue to run. if the overload indicator light comes on and power generation stops, proceed as follows:
5.3.1.
turn off any connected electrical devices and stop the engine.
5.3.2.
reduce the total wattage of connected appliances to the rated output.
5.3.3.
check for blockages in the cooling air inlets and around the control unit and remove.
5.3.4.
restart the engine
note:- The overload indicator light may come on for a few seconds at first when using electrical devices that require a large starting
current, such as a compressor or a submersible pump. this is not a malfunction.
5.4.
ac pilot light (green)
the Ac Pilot light comes on when the engine starts and power is produced.
5.5.
Dc protector
the dc protector turns to "off" automatically when an electrical device connected to the generator is operating above the rated