Custom Energy Savings Settings
10 – TEMPERATURE RECOVERY TIME
(00 - 60; 15* default setting) Select the maximum time
allowed for a HVAC unit to attain temperature as defined
by Heat and Cool "Recovery Temperature".
"Temperature Recovery Time" selected here and the actual
temperature recovery ability of the HVAC unit are used
to calculate setback temperatures. Calculated setback
temperatures maximize energy savings and at the same
time ensure that a comfortable room temperature (defined
as Heat and Cool "Recovery Temperature") will be restored
within the selected "Temperature Recovery Time".
Setting the "Temperature Recovery Time" to "00", disables
temperature recovery. When temperature recovery is
disabled, thermostat will use the Minimum and Maximum
Setback Temperatures as setback set points.