5.1.7.2 If the switch is kept pressed for 5 seconds, buzzer ring two times and unit enter enter test run mode.
5.1.7.3 Press the switch again, and then closes.
5.1.7.4 Enter emergency operation from timer mode, then timer is cancelled.
7.1.9 Test run:
5.1.8.1 The temperature sensor of inlet air doesn't work, and compressor starts (but subject to the limit of
-minute delay excluding the first time), and high wind, cooling, and air door is open. The indoor fan motor runs, running
indicator lights up, compressor relay and the one of outdoor fan motor is closed
5.1.8.2 During test run:
The prevention of freezing of evaporator doesn't work.
Current cross control doesn't work.
The control of current cross peak expiration doesn't work.
Temperature control doesn't work.
Temperature expiration control doesn't work.
7.1.10 memory function:
The memory function of power down is available, and the auto recovery function of power on is optional. (In auto,
heating, cooling, or defrosting status, press the "sleeping" button 10 times within 5 seconds, and the auto recovery
function of power on can be set on/off. If the buzzer rings 4 times, the the auto recovery function of power on is
available; If the buzzer rings 2 times, the the auto recovery function of power on is unavailable.)
If there is no EEPROM, the unit is taken off the 'off' function of the memory function of power down. But the
memory function of power down can also be set on/off, and the data is the default value of chip.
7.1.11 Alarm from indoor fan motor:
2 minutes later after the indoor fan motor is charged, and the impulse from fan motor is not detected, hen send
alarm signals.
7.2 Value of Thermistor
R25 =23KΩ±3.5%
B25 /50 =4200K±3%
Max.(KΩ)
Temp.(℃)
-30
568.8372
-29
530.9600
-28
495.8488
-27
463.2850
-26
433.0683
-25
405.0156
-24
378.9588
-23
354.7440
-22
332.2300
-21
311.2873
-20
291.7969
-19
273.6494
                                                                                   
Room sensor(Indoor unit)
Normal(KΩ)
Min.(KΩ)
501.0746
440.8435
468.6491
413.1441
438.5314
387.3645
410.5433
363.3602
384.5212
340.9980
360.3153
320.1558
337.7879
300.7211
316.8126
282.5905
297.2732
265.6686
279.0627
249.8676
262.0831
235.1067
246.2437
221.3111
 
19
                                                             
Functions and Control
 
Tolerance(℃)
-1.97
-1.95
-1.93
-1.91
-1.90
-1.88
-1.86
-1.84
-1.82
-1.80
-1.78
-1.76
Domestic air conditioner
 
1.75
1.74
1.72
1.71
1.70
1.69
1.67
1.66
1.64
1.63
1.62
1.60
   