Download Print this page

GE Lumination LB96-UNV-840-A-P Installation Manual

Light bar retrofit kit series

Advertisement

Quick Links

GE
Lighting
Lumination
Light Bar Retrofit Kit Series
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF FIRE OR ELECTRIC SHOCK
• Disconnect power before installation or maintenance.
• Luminaire wiring and electrical parts may be damaged when drilling for
installation of LED retrofit kit. Check for enclosed wiring and components.
• LED Retrofit Kit installation requires knowledge of luminaires electrical
systems. If not qualified, do not attempt installation. Contact a qualified
electrician.
• Install this kit only in luminaires that have the construction features and
dimensions shown in the photographs and/or drawings and where the
input rating of the retrofit kit does not exceed the input rating of the
luminaire.
• Only those open holes indicated in the photographs and/or drawings
may be made or altered as a result of kit installation. Do not leave any
other open holes in an enclosure of wiring or electrical components.
• To prevent wiring damage or abrasion, do not expose wiring to edges of
sheet metal or other sharp objects.
• The Light Bar may fall down if not installed properly, follow installation
instructions.
• Wear safety glasses and proper aid during installation and maintenance.
Save These Instructions
These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problem arise which are
not covered sufficiently for the purchaser's purpose, the matter should be referred to General Electric Company. GE Lighting does not claim
liability for any installation not performed according to this guide or not by a qualified electrician.
Tools Required
• Screwdriver Philips #2
• Portable drill with Philips #2 bit
• Wire cutter
imagination at work
LED Luminaires
TM
WARNING
CAUTION!
AVERTISSEMENT
RISQUE D'INCENDIE OU D'ELECTROCUTION
• Débrancher l'alimentation avant l'installation ou la maintenance.
• Le câblage du luminaire ainsi que ses composantes électriques peuvent
être endommagés lors du perçage requis pour l'installation de l'ensemble
de mise à niveau à DEL. Vérifiez le câblage et les composants.
• L'installation de l'ensemble de mise à niveau à DEL requiert des
connaissances en système électrique d'éclairage. Si vous n'avez pas les
qualifications adéquates, ne procédez pas à l'installation et contactez un
électricien qualifié.
• N'installez cet ensemble de mise à niveau à DEL que sur des luminaires
ayant une construction et des dimensions indiquées sur les photos et
dessins et ce, seulement dans la mesure où les spécifications d'entrées
de l'ensemble de mise à niveau à DEL n'excède pas les spécifications
d'entrée du Luminaires dans lequel il sera installé.
• Seules les ouvertures indiquées sur les photos et dessins peuvent être
faites ou modifiées lors de l'installation de l'ensemble de mise à niveau à
DEL. Ne laissez aucune ouverture dans le boitier ou le compartiment où
se trouvent les composants électriques.
• Afin de prévenir tout dommage ou abrasion aux fils électriques, évitez
que ceux-ci ne viennent en contact avec les bordures métalliques ou
d'autres ojets pointus.
• Les barres lumineuses peuvent tomber s'il ne sont pas installés
correctement. Suivre les instructions d'installations.
• Portez des lunettes protectrices ainsi que tout autre protection
nécessaire durant l'installation et la maintenance.
For Your Safety
Read and observe all CAUTIONS and WARNINGS shown throughout
these instructions.
• Installation to be performed by factory trained or qualified personnel.
Ensure this manual is provided to the installers and users.
• Use this product only in the manner intended by the manufacturer. If there
are any questions or concerns, contact the manufacturer.
Installation Guide
ATTENTION!

Advertisement

loading

Summary of Contents for GE Lumination LB96-UNV-840-A-P

  • Page 1 Should further information be desired or should particular problem arise which are not covered sufficiently for the purchaser’s purpose, the matter should be referred to General Electric Company. GE Lighting does not claim liability for any installation not performed according to this guide or not by a qualified electrician.
  • Page 2 Table 1: Light Bar Retrofit Kit Contents Item Quantity Lens assembly Light engines assembly Retrofit kit accessory bag Mounting brackets 2 or 3 Drill point screws T8/T5 socket hole cover 4 or 8 T8 HO socket hole covers 0, 4 or 8 5/16”...
  • Page 3 Table 2: Required Driver Accessory Kit and Dimensions for Fixture Installation The table below lists: • Light Bar Retrofit Kit nominal input power. • Light engine model/length required and number of light engine interconnection wires required (provided). • Required driver needed vs. light bar retrofit kit type. •...
  • Page 4 Light Bar Retrofit Kit Installation Steps Turn of power. Open the ballast compartment cover. Remove the existing ballast and save the ballast mounting screw(s). Remove the existing fluorescent tube sockets Install fluorescent tube socket covers provided and wiring. (two models are included in accessories bag). (not to scale) (48”...
  • Page 5 Retrofit Kit Light Bar Retrofit Kit Light Bar (4ft) (4ft) Out (+) Line Out (-) LED Driver (Class 2) 0-10V (+) Dimming Neutral Wires 0-10V (-) Ground GND screw Wiring Diagram A 8ft Configuration (1 Driver) For LB96 Kit provided with one XI075C200V054BPT1 driver only: •...
  • Page 6 Red and blue Install bushing output wires Drill hole Drill one 5/16” hole in the driver compartment’s Pass the red and blue driver output wires through cover towards the end closest to the driver and the bushing and replace the driver cover. Make install the white snap bushing into the hole.
  • Page 7 GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. © 2016 GE.

This manual is also suitable for:

Lumination lb48-unv-840-a-p