Wiring Diagram A
8ft Configuration (1 Driver)
6A
For LB96 Kit provided with one XI075C200V054BPT1 driver only:
• Install the 23.5"/60cm black, white and yellow-green wires provided in accessories kit to the driver input push-in connectors.
• Install the 23.5"/60cm red and blue wires provided in accessories kit to the driver output push-in connectors.
Optional:
• If 0-10V dimming wires are present in the retrofitted fixture, connect 0-10V dimming wires to the driver dimming
wires or to dimming push-in connectors whichever is present. Connect violet (+) dimming wire to driver violet
dimming wire/push-in connector. Connect gray (-) dimming wire to driver gray dimming wire/push-in connector.
If ferrite bead is present on AC/Dimming wires provided, do not remove. Make connections to the driver on the end
where ferrite is placed.
Wiring Diagram B
4ft Configuration
6B
4ft configurations:
Connect led driver(s) to AC main using UL listed wire connectors. Refer to Table 2.
Retrofit Kit Light Bar
(4ft)
Line
Neutral
Ground
Retrofit Kit Light Bar
Line
Neutral
Ground
GND screw
Retrofit Kit Light Bar
LED Driver
(Class 2)
GND screw
(4ft)
Out (+)
Out (-)
LED Driver
(Class 2)
0-10V (+)
0-10V (-)
(-)
(4ft)
(+)
Out (+)
Out (-)
0-10V (+)
0-10V (-)
(-)
(+)
Dimming
Wires
Dimming
Wires