Connector Assignment Usb And Rs-232 Cable - Siemens SIMATIC MV320 Operating Instructions Manual

Handheld reading systems
Hide thumbs Also See for SIMATIC MV320:
Table of Contents

Advertisement

Connecting (SIMATIC MV320)

4.2 Connector assignment USB and RS-232 cable

Removing the cable
1. Insert a paper clip into the opening on the side of the device handle.
2. Remove the cable carefully from the device.
4.2
Connector assignment USB and RS-232 cable
USB cable
Example with connector assignments:
Table 4- 1
Connector A
1
2
3
4
Housing
Description of the connector assignment of the reader (Page 24).
22
Connector table
Designation
VIN
DM
DP
GND
-
Wire
Color
24 AWG
Red
28 AWG
White
28 AWG
Green
24 AWG
Black
Shield
Blank
Operating Instructions, 08/2015, C79000-G8976-C352-03
Connector B
1
2
3
10
Housing
SIMATIC MV320 / SIMATIC MV325