If your system is in...
An HA pair
A stand-alone configuration
6. Connect the power supplies to different power sources, and then turn them on.
7. Boot each node to Maintenance mode:
a) As each node starts the booting, press Ctrl-C to interrupt the boot process when you see the
message Press Ctrl-C for Boot Menu.
Note: If you miss the prompt and the controller modules boot to ETERNUS AX/HX Series, enter halt,
and then at the LOADER prompt enter boot_ETERNUS AX/HX Series, press Ctrl-C when
prompted, and then repeat this step.
b) From the boot menu, select the option for Maintenance mode.

Verifying and setting the HA state of the chassis

You must verify the HA state of the chassis, and, if necessary, update the state to match your system
configuration.
Procedure
1. In Maintenance mode, from either controller module, display the HA state of the local controller module
and chassis: ha-config show
The HA state should be the same for all components.
2. If the displayed system state for the chassis does not match your system configuration:
a) Set the HA state for the chassis: ha-config modify chassis HA-state
Then perform these steps...
a. With the cam handle in the open position,
firmly push the controller module in until
it meets the midplane and is fully seated,
and then close the cam handle to the locked
position.
Attention: Do not use excessive force
when sliding the controller module
into the chassis to avoid damaging the
connectors.
b. If you have not already done so, reinstall the
cable management device.
c. Bind the cables to the cable management
device with the hook and loop strap.
d. Repeat the preceding steps for the second
controller module in the new chassis.
a. With the cam handle in the open position,
firmly push the controller module in until
it meets the midplane and is fully seated,
and then close the cam handle to the locked
position.
Attention: Do not use excessive force
when sliding the controller module
into the chassis to avoid damaging the
connectors.
b. If you have not already done so, reinstall the
cable management device.
c. Bind the cables to the cable management
device with the hook and loop strap.
d. Reinstall the blanking panel and then go to the
next step.