Siemens Reyrolle 7SR45 Engineering Manual

Hide thumbs Also See for Reyrolle 7SR45:

Advertisement

Quick Links

Reyrolle
Engineering Guide
7SR45
V03.00
Manual
C53000-G7040-C102-1
Preface
Open Source Software
Table of Contents
Reydisp Evolution Overview
Essential Steps during Engineering
Configuration Software
Appendix
Index
1
2
3
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Reyrolle 7SR45

  • Page 1 Preface Open Source Software Table of Contents Reyrolle Reydisp Evolution Overview Engineering Guide Essential Steps during Engineering 7SR45 Configuration Software Appendix V03.00 Index Manual C53000-G7040-C102-1...
  • Page 2 Disclaimer of Liability Copyright Subject to changes and errors. The information given in Copyright © Siemens 2020. All rights reserved. this document only contains general descriptions and/or The disclosure, duplication, distribution and editing of this performance features which may not always specifically...
  • Page 3: Preface

    Further Documentation [dw_7SR45_furtherdocumentation_engineeringguide, 1, en_US] • Device manual The device manual describes the functions and applications of the Reyrolle 7SR45 device. The printed manual for the device has the same informational structure. • Hardware manual The hardware manual describes the hardware building blocks and device combinations of the Reyrolle 7SR45 device family.
  • Page 4 The engineering guide describes the essential steps when engineering with Reydisp Evolution. In addi- tion, the engineering guide shows you how to load a planned configuration to a Reyrolle 7SR45 device and update the functionality of the Reyrolle 7SR45 device.
  • Page 5 Preface WARNING WARNING means that death or severe injury may result if the measures specified are not taken. Comply with all instructions, in order to avoid death or severe injuries. ² CAUTION CAUTION means that medium-severe or slight injuries can occur if the specified measures are not taken. Comply with all instructions, in order to avoid moderate or minor injuries.
  • Page 6 Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 7: Open Source Software

    License Conditions provide for it you can order the source code of the Open Source Software from your Siemens sales contact – against payment of the shipping and handling charges – for a period of at least 3 years after purchase of the product. We are liable for the product including the Open Source Software contained in it pursuant to the license conditions applicable to the product.
  • Page 8 Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 9: Table Of Contents

    Table of Contents Preface................................3 Open Source Software..........................7 Reydisp Evolution Overview........................11 Reydisp Evolution ......................12 Offline Mode and Online Mode..................13 User Interface........................14 1.3.1 Functional Sections of the User Interface ..............14 1.3.2 Settings Templates...................... 14 Essential Steps during Engineering......................15 Preconfiguration Requirements..................16 Setting the Relay via Reydisp Evolution................
  • Page 10 Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 11: Reydisp Evolution Overview

    Reydisp Evolution Overview Reydisp Evolution Offline Mode and Online Mode User Interface Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 12: Reydisp Evolution

    Reydisp Evolution Overview 1.1 Reydisp Evolution Reydisp Evolution What is Reydisp Evolution? Reydisp Evolution is a Windows based suite of software tools, providing the means for the user to fully configure the 7SR45 Argus relay. The setting configuration tool allows you to apply settings, interrogate settings, and retrieve events and fault records from the 7SR45 Argus relay.
  • Page 13: Offline Mode And Online Mode

    Reydisp Evolution Overview 1.2 Offline Mode and Online Mode Offline Mode and Online Mode In the Offline mode, all of the data to be edited for the 7SR45 Argus relay is available in files and there is no physical connection to the 7SR45 Argus relay. The following list provides an overview of the tasks you can work with in the Offline mode: •...
  • Page 14: User Interface

    1.3 User Interface User Interface Functional Sections of the User Interface 1.3.1 For more information about Reydisp Evolution configuration software, visit the Siemens Internet site https:// www.siemens.com/reyrolle. Download the Reydisp Evolution Set up and install Reydisp Evolution to access the Help menu.
  • Page 15: Essential Steps During Engineering

    Essential Steps during Engineering Preconfiguration Requirements Setting the Relay via Reydisp Evolution Configuring the Relay Serial Data Communication Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 16: Preconfiguration Requirements

    To set the relay using a communication port, you need the following: • PC or laptop computer with Reydisp Evolution Version 9.51.02 or higher installed. You can download Reydisp Evolution from the Siemens Internet site https://www.siemens.com/reyrolle under the submenu Software.
  • Page 17 Essential Steps during Engineering 2.1 Preconfiguration Requirements Rear RS485 Connection [dw_RS485-connection_to_PC, 2, en_US] Figure 2-2 RS485 Connection to PC Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 18: Setting The Relay Via Reydisp Evolution

    Essential Steps during Engineering 2.2 Setting the Relay via Reydisp Evolution Setting the Relay via Reydisp Evolution When the Reydisp software is running, all the available communication ports are automatically detected. On the homepage of Reydisp Evolution, open the submenu File and select Connect. ²...
  • Page 19 Essential Steps during Engineering 2.2 Setting the Relay via Reydisp Evolution NOTE In Reydisp Evolution, check that the relay address in the Relay menu is the same as that of the 7SR45 Argus relay address. This is applicable for 7SR450[1/3]-x[H/J]A20-1AA0 and 7SR450[2/4]-x[H/J]B20-1AA0. Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 20: Configuring The Relay Serial Data Communication

    Essential Steps during Engineering 2.3 Configuring the Relay Serial Data Communication Configuring the Relay Serial Data Communication You can configure the 7SR45 Argus relay by using the keys on the relay fascia. Scroll down from the SETTING MODE and navigate to the COMMUNICATION menu and change the settings for the communication port if needed.
  • Page 21: Configuration Software

    Configuration Software Get Device Data Settings Editor Window Changing Settings Using the Matrix Editor Help Hints Using the Config Editor Send Settings Compare Settings Groups Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 22: Get Device Data

    Configuration Software 3.1 Get Device Data Get Device Data From the Reydisp Evolution software, download the settings, fault records and events records from the connected 7SR45 Relay. Get Settings • The settings from a device can be retrieved by using the Relay →Settings → Get Settings command or by clicking the Get Settings icon shown below.
  • Page 23 Configuration Software 3.1 Get Device Data Get Events Record • The event record from a device can be retrieved by using the Relay → Events → Get Events command or by clicking the Get Events icon shown below [sc_getevents, 1, en_US] The event record is displayed in Reydisp Evolution software as follows: [sc_eventrecord, 1, en_US] Figure 3-2...
  • Page 24: Settings Editor Window

    Configuration Software 3.2 Settings Editor Window Settings Editor Window A settings editor window is used to manipulate settings. Reydisp Evolution can display several settings editor windows. This window allows settings to be downloaded from a device, changed, and uploaded to the device. Settings can also be saved to and reloaded from the disk.
  • Page 25: Changing Settings

    Configuration Software 3.3 Changing Settings Changing Settings There are different methods to change settings depending on the type of setting. To change a setting, select the setting in the list to display the appropriate editor. [sc_changingsettings, 1, en_US] Figure 3-4 Changing Settings Selectable Setting If the setting is a predefined option, select the Parameter setting and select the Value from the list box.
  • Page 26 Configuration Software 3.3 Changing Settings [sc_textsettings, 1, en_US] Figure 3-6 Text Settings Bit Selection Setting For bit selection settings, a button is displayed next to the setting. Double click the setting to open the bitwise editor. After changing the values, click OK to save. [sc_bitselectionsettings, 1, en_US] Figure 3-7 Bit Selection Settings...
  • Page 27: Using The Matrix Editor

    Configuration Software 3.4 Using the Matrix Editor Using the Matrix Editor To use a matrix editor, click the appropriate matrix tab (input matrix, output matrix) and make it active. Settings are listed in the left panel and the controlled object across the top of the right panel. Click the check box to select a controlled object.
  • Page 28: Help Hints

    Configuration Software 3.5 Help Hints Help Hints The following figure displays the help hints when you hover over a setting. The help hint provides a descrip- tion for each setting. [sc_helphints, 1, en_US] Figure 3-9 Help Hints The following settings display that the hints can be turned on or turned off from the context menu by clicking the right mouse button.
  • Page 29: Using The Config Editor

    Configuration Software 3.6 Using the Config Editor Using the Config Editor To use the Config editor, click the Config tab to activate it. A subset of settings is displayed in the editor. Click the check box on the left side of each setting to enable or disable it. [sc_configeditor, 1, en_US] Figure 3-11 Config Editor...
  • Page 30: Send Settings

    Configuration Software 3.7 Send Settings Send Settings • To upload the settings in the relay, use the Relay → Settings → Send All Settings commands or click Send All Settings icon shown below. [sc_sendsettings_icon, 1, --_--] • Select the required Settings Group (Group 1 or Group 2) [sc_sendsettingstowhichgroup, 1, --_--] Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 31: Compare Settings Groups

    Configuration Software 3.8 Compare Settings Groups Compare Settings Groups To compare settings groups, use the Relay → Settings → Compare Setting Groups command. • To compare settings groups, open the Compare Settings window (Figure 3-12) • Enter the 2 setting editors in the Compare Settings window and click OK. •...
  • Page 32 Configuration Software 3.8 Compare Settings Groups [sc_comparesettingscolor, 1, --_--] Figure 3-13 Option for Color Change for Setting Differences [sc_comparesettings, 1, en_US] Figure 3-14 Comparison of Settings Group Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 33: A Appendix

    Appendix Revision History Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...
  • Page 34: Revision History

    Appendix A.1 Revision History Revision History Software Revision History • 2020/08 2438H80001R2f-1a Protection function 51-1 setting range change to 0.1 ⋅ I rated 2.0 ⋅ I rated • User-Programmable LED feature added 2020/05 2438H80001R2e-1b Software maintenance 2019/12 2438H80001R2e-1a Thermal overload protection function (49) added 2019/05 2438H80001R2c-1b Software maintenance to suit customer requirements...
  • Page 35: Index

    Index Reydisp Evolution set up 14 Reydisp Evolution user interface 14 Bit selection setting 26 Selectable setting 25 Send Settings 30 Changing settings 25 Setting the relay via Reydisp Evolution 18 Compare Settings Groups 31 Settings Editor Window 24 Configuring the relay serial data communication 20 Settings Templates 14 Connection manager 18 Text setting 25...
  • Page 36 Reyrolle, Engineering Guide, Manual C53000-G7040-C102-1, Edition 08.2020...

Table of Contents