Page 1
SUN2000-(12KTL, 15KTL, 17KTL, 20KTL)-M0 User Manual Issue Date 2020-07-02 HUAWEI TECHNOLOGIES CO., LTD.
Page 2
Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
SUN2000 before installing and operating it. NO TE The SUN2000-8KTL-M0 and SUN2000-10KTL-M0 inverters are applicable only to Australia. Intended Audience This document is intended for: ●...
When operating Huawei equipment, in addition to following the general precautions in this document, follow the specific safety instructions given by Huawei. Huawei will not be liable for any consequence caused by the violation of the safety operation regulations and design, production, and usage standards.
Page 39
SDongleA-03 Quick Guide (4G) . You can obtain the quick guide at operation, see https:// support.huawei.com/enterprise by searching for the Smart Dongle model. ● Note b: The SUN2000-8KTL-M0 and SUN2000-10KTL-M0 inverters are applicable only to Australia. Table 5-2 Cable description Name Type...
Specifications ● Note a: The minimum cable diameter depends on the fuse rating on the AC side. ● Note b: The SUN2000-8KTL-M0 and SUN2000-10KTL-M0 inverters are applicable only to Australia. ● Note c: The SUN2000-8KTL-M0 and SUN2000-10KTL-M0 inverters are applicable only to Australia.
● In the Smart Dongle networking scenario, the SmartLogger1000A cannot be connected. ● The Smart Power Sensor is necessary for export limitation. Only the DTSU666-H Smart Power Sensor (provided by Huawei) can be used. ● The Smart Power Sensor and Smart Dongle need to be connected to the same inverter.
Page 68
This document uses the FusionSolar app as an example to describe the commissioning method. For the SUN2000 app, perform operations as required. ● To obtain the SUN2000 App, scan the QR code or search for SUN2000 in Huawei AppGallery, download the latest installation package, and install the SUN2000 app by following the instructions.
For details, see the . You can scan the QR code to obtain it. 6.3.2 Scenario 2: SmartLogger1000A Networking Scenario Distributed PV Plants Connecting to Huawei Hosting Cloud Quick See the Guide (Distributed Inverters + SmartLogger1000A + RS485 Networking) You can scan the QR code to obtain it.
SUN2000-(12KTL, 15KTL, 17KTL, 20KTL)-M0 User Manual 9 Technical Data Technical Data NO TICE The SUN2000-8KTL-M0 and SUN2000-10KTL-M0 inverters are applicable only to Australia. Efficiency Technical SUN2000-8 SUN2000-1 SUN2000-1 SUN2000-1 SUN2000-1 SUN2000-2 Specificatio KTL-M0 0KTL-M0 2KTL-M0 5KTL-M0 7KTL-M0 0KTL-M0 Maximum 98.5% 98.5%...
Function Description If PV modules or cables are incorrectly connected or damaged, electric arcs may be generated, which may cause fire. Huawei inverters provide arc detection to ensure the safety of users' lives and property. This function is enabled by default. To disable this function, go to the Device commissioning screen from the FusionSolar app, choose Settings >...