Field I/O Wiring Examples; Input Opto Wiring - Siemens SIMATIC HawkEye 1600T Series Manual

Smart camera
Table of Contents

Advertisement

Chapter
2
System Components

Field I/O Wiring Examples

Input Opto Wiring

Figure 2–9 shows the input opto wiring for isolated NPN and PNP sources.
FIGURE 2–9.
NPN Sink
IN A (or IN B)
15-30V
IN B (or IN A)
Signal
Figure 2–10 shows the input opto wiring for non-isolated NPN and PNP sources.
FIGURE 2–10.
NPN Sink
GPIO IN COM
15-30V
GPIO x
Signal
See Note 1
GPIO OUT COM
Note 1: GPIO OUT COM typically connected to ground.
Note 2: GPIO OUT COM typically connected to Voltage.
2-14
Trigger Input Opto Wiring (NPN and PNP)
Camera
GPIO Input Opto Wiring (NPN and PNP)
Camera
SIMATIC HawkEye™ 1600T Smart Camera Guide
PNP Source
15-30V
Signal
IN A (or IN B)
IN B (or IN A)
PNP Source
15-30V
See Note 2
GPIO OUT COM
Signal
GPIO x
GPIO IN COM
Camera
Camera