OOHC941 Selectable Application Profiles
Telecommunication (See
Special Application)
Incipient (See Special
Application)
Ion equivalent
Data Center (open area
protection)
Computer Room
Precious Storage
Power Generation
Hospital
Health Care
Dormitory
Utility Room
Lobby
Office
Hotel
School
Warehouse
Manufacturing
Parking Garage
Open Environment
EMI noise
Hostile
Data Center w/CO (open
area protection)
Hotel w/CO
Hostile w/CO
Duct w/CO
OOHC941 CO Life Safety Profile
Balanced US1
The Balanced US1 parameter set meets UL2075 and fulfills sensitivity requirements from UL2034,
CSA 6.19-1, and CAN/ULC-S588.
4
Very controlled environment, clean, temperature closely regulated, high value clean signal
processing equipment operating and high air velocity conditions. Often has high ceilings. Meets
the detection requirements of NFPA 76 Standard for the Protection of Telecommunication
Equipment by providing a Very Early Warning Fire Detection Pre-Alarm to prevent downtime and
maintain critical business continuity.
Very controlled environment, clean, temperature closely regulated. Provides early warning
detection alarm.
Used as an alternative to Ionization detector. Sensitive to flaming fires and small fire signature
particles. Can be used for cross zoning suppression requirements.
Used for open area protection in controlled environment containing data processing equipment.
Very controlled environment, clean, temperature closely regulated, high value clean signal
processing equipment operating and high air velocity conditions.
Sensitve materials or equipment storage, clean dust-free environment, earliest warning desired.
Controlled environment, minor or no temperature swing, RF, welding, electrical arcing present.
Some airborne (deceptive phenomena) contaminant present.
Controlled clean environment. High level risk. Some exposure RF generating equipment.
Exposure to cleaning solvents.
Higher level risk, relatively clean, electronic equipment. Some chemical and cleaning vapor
exposure.
Airborne dust and temperature changes, living quarters. Cooking fumes, smoking and steam.
Transformer room, normal to somewhat dirty environment, heat from running equipment.
Relatively clean area, temperature changes, cellular phones, some outside particulate.
Reasonably clean, climate-controlled atmosphere.
Life safety, some temperature swings, steam, smoking and cooking possible.
Life safety, some temperature swings and airborne contaminants.
Airborne dust, equipment, forklift and light to medium dock area and exhaust fumes.
Semi-controlled environment can include soldering, welding, airborne contaminants including
chemical vapor exposure.
Airborne dust. Car and diesel fumes, large temperature swings.
Large open areas, atriums, arenas, stadiums. Temperature swings, deceptive phenomena from
fumes possible.
Electrical interface, RF and our specialized equipment generating electrical signal. Other
environmental conditions are normal.
Dirty, dusty, humid, operating equipment, RF present, wide temperature swings.
Used for open area protection in controlled environment containing data processing equipment.
Provides CO sensor supporting nuisance alarm avoidance, some temperature swings, steam,
smoking and cooking possible.
Adds CO sensor to robust smoke detection for avoiding nuisance alarms from deceptive
phenomena. Dirty, dusty, humid, operating equipment, RF present, wide temperature swings.
Smoke detection in duct with CO support. High air velocity, dirty, dusty, humid, wide temperature
swings.