Field intelligent device – mount-anywhere series - wafer electromagnetic flowmeter

Advertisement

R(PT)½Male Screw (Two places)
3.46(88)
1.57(40)
Note1: Cable glands are not provided for LF414 of FM and
CSA approved type.
Refer to the part of Cable connection port at
detector.
Note2: 1 inch = 25.4mm
Unit: inch(mm)
4.96(126)
1. 38(35) 3.58(91)
L1
Figure 8. Separate type detectors LF410/LF414
Meter sizes 1 1/2"(40mm) to 4"(100mm)
ASME B 16.5 class 150 and class300 dimensions:
Meter size
L1
(inch)
(inch)
1-1/2
3.94
2
4.33
3
4.33*
4
4.72*
EN 1092-1 PN16 and JIS B 2220 10K dimensions:
Meter size
L1
(mm)
(mm)
40
100
50
110
80
110*
100
120*
The dimension of L1 is changes when the material of
grounding ring is chosen Pt-Ir or Ta
Meter size
1/2"(15mm)
1"(25mm)
1 1/2"(40mm)
2"(50mm)
3"(80mm)
4"(100mm)
EJL-136F
L2
D1
Weight
(inch)
(inch)
(lbs)
7.48
3.35
approx. 9
8.15
4.02
approx. 11
9.13
5.00
approx. 13
10.39
6.26
approx. 20
L2
D1
Weight
(mm)
(mm)
(kg)
190
85
approx. 4
207
102
approx. 5
232
127
approx. 6
264
159
approx. 9
L1
3.03 inch(77mm)
3.74 inch(95mm)
4.53 inch(115mm)
4.96 inch(126mm)
4.96 inch(126mm)
5.35 inch(136mm)