Download Print this page
Sealey PPHY Manual

Sealey PPHY Manual

Cat iv 1000v high voltage tester

Advertisement

Quick Links

Thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer To
Wear eye
Instructions
Protection
1. sAfeTy
WArnIng! Please read manual carefully before any operation. This manual includes safety warning and safety requirement, which
help user to operate the equipment safely.
After measuring AC/dC voltage source for 3 minutes, the tester must take a rest for 1 minute.
9
Never measure the voltage beyond specified (1000V).
8
do noT operate the equipment near flammable gasses.
8
do noT operating the equipment with wet hands.
8
Keep hands and fingers behind the barriers during measurements.
9
do noT unlock and open the battery case during measurements.
8
Confirm the function of the equipment with a known source before measure unknown voltage source.
9
do noT make any measurement when there is abnormal condition, such as broken case or exposed metal parts are present an the
8
instrument, test probes, and cables.
do noT modify the equipment.
8
Take extreme caution when operating with a live circuit.
9
LED only function properly when temperature is between 0 ~ 50°C.
9
Before using a voltage detector with audible indicator at locations with a high background noise level, it has to be determined
9
whether the audible signal is perceptible.
2. InTroduCTIon
Professional two pole voltage tester CAT IV 1000V for checking high
voltage on electric/hybrid vehicles. Suitable for checking AC mains and
DC power supplies between 6-1000V DC and 24-1000V AC. Can also
be used for checking voltage and polarity on car batteries and
continuity testing of dC circuits. Includes a self-test function and
illumination light. EN61243-3, IP65, CE certified. Requires 2 x AAA
1.5V batteries (not supplied).
3. sPeCIfICATIon
Model no: .................................................................... PPHy
Accuracy: .............................................................+/-(3%+3)V
CAT Category: ..................................................CAT IV 1000V
IP Rating: ........................................................................IP65
Maximum Current: ...................................... <3.5mA @ 1000V
Power: .................................. 2 x AAA Batteries (not supplied)
Voltage: ..................................... 6-1000V DC & 24-1000V AC
4. PrePArATIon
4.1.
PoWer on/ self-dIAgnosTIC
4.1.1.
Press the "ON/ OFF" button on the main probe first and then
on the second probe, short the two metal probes (fig.2). The
power will automatically turn on, and the equipment start a
self-diagnostic test.
4.1.2.
All indicators on LCD will light up (fig.3), and buzzer will sound during the normal self-
diagnostic test.
do noT operate the equipment if any abnormality occurs during the self-diagnostic test.
8
4.1.3.
LCD will flash 5 times when battery power is lower than 2.2 ± 0.1V. Please change the battery.
4.2.
Trouble sHooTIng
4.2.1.
If any of the following happens, open the battery case and close it again after 5 seconds.
Conduct a self-diagnostic test after closing the case again see 4.1.
Problems:(1) Cannot perform self-diagnostic test before or after the operation of the equipment.
(2) Cannot auto power off.
© Jack Sealey limited
CAT IV 1000V HIgH VolTAge TesTer
HybrId VeHICles
Model no:
Wear Protective
electrical
High Voltage
Shock
Gloves
Hazard
Original Language Version
PPHy
Warning!: Use
Suitable For live
High Voltage
Working
Safety Mat
Second Probe (-)
DC positive (+) indicator
DC negative (-) indicator
Probe Barrier
Probe Clip
Power Switch
fig.1
1 000 V
Main Probe (+)
Illumination Light
Non Contact Voltage Sensor
Non contact voltage indicator
LCD Display
Probe Barrier
Light/ Non contact sensing switch
Power Switch
fig.2
PPHY Issue 1 18/07/19

Advertisement

loading

Summary of Contents for Sealey PPHY

  • Page 1 PPHy Model no: Thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 ‰ 5.6. IlluMInATIon 5.6.1. Long press and hold the “LIGHT/NON-CONTACT VOLTAGE SENSING SWITCH” to switch on the illumination light. WArnIng! Illumination function and non-contact voltage sensing function share the ‰ same button, be aware when using these two functions. fig.6 fig.7 Original Language Version © Jack Sealey limited PPHY Issue 1 18/07/19...
  • Page 3 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: no liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. sealey group, Kempson Way, suffolk business Park, bury st edmunds, suffolk. IP32 7Ar 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk...