FEATURES MODEL AGG09LVCB / AOG09LVCN AGG12LVCB / AOG12LVCN AGG14LVCB / AOG14LVCN FEATURES Energy efficiency class MODEL AG G09LVCB AG G12LVCB AG G14LVCB Cooling Heating ALL DC fan motor compressor DC fan motor DC Fan motor DC compressor Low outdoor air temperature correspondence...
Page 5
Powerful heating at low outdoor temperature Keeping the high heating capacity at low outdoor temperature. Heating capacity (kW) 09 Class -15°C -7°C 2°C Outdoor temperature Heating capacity (kW) 12 Class -15°C -7°C 2°C Outdoor temperature Heating capacity (kW) 14 Class -15°C -7°C 2°C...
Page 6
Flexible & easy installation Piping space is wide and connection work is easy. Beneath standard window Standard concave portion Wall Half concealed (Optional parts necessary) Min.940 Min. Min. Min. 730 Max. Max. 150 (unit:mm) (unit:mm) : t i : t i Choice of 6-direction drain &...
WIRELESS REMOTE CONTROLLER FEATURES 4 mode timer setup available (ON / OFF / PROGRAM / SLEEP). Easy operation. Easy to change signal code (max. 4 units) by button operation. Simple function setting ...
Page 8
FUNCTIONS Signal transmitter MODE button 10°C HEAT button SET TEMP. button ( ECONOMY button SLEEP button TIMER MODE button FAN button START/STOP button SET button SWING button TIMER SET ( ) button CLOCK ADJUST button TEST RUN button •This button is used when installing the air conditioner, and should not be used under normal conditions, as it will cause the indoor unit’s thermostat function to operate incorrectly.
FAN PERFORMANCE AND CAPACITY 7-1. AIR VELOCITY DISTRIBUTION MODEL : AGG09LVCB, AGG12LVCB, AGG14LVCB Unit : m/s TOP VIEW FLOW CONTROL PANEL : Horiz. Note: LOUVER :Center Fan speed : H i Operation mode:FAN Fan select : UPPER&LOWER :UPPER FAN :LOWER FAN LOWER UPPER...
7-2. AIRFLOW MODEL : AGG09LVCB, AGG12LVCB Cooling Number of rotations Airflow Fan speed [r.p.m] (UPPER/LOWER) m³/h HIGH 1190/1000 m³/h 1000/850 m³/h 820/690 m³/h QUIET 660/560 zHeating Number of rotations Airflow Fan speed [r.p.m] (UPPER/LOWER) m³/h HIGH 1240/1040 m³/h 1040/880...
Page 17
MODEL : AGG14LVCB Cooling Number of rotations Airflow Fan speed [r.p.m] (UPPER/LOWER) m³/h HIGH 1330/1120 m³/h 1100/930 m³/h 890/750 m³/h QUIET 660/560 zHeating Number of rotations Airflow Fan speed [r.p.m] (UPPER/LOWER) m³/h HIGH 1330/1120 m³/h 1100/930 m³/h 860/730 m³/h...
ELECTRIC CHARACTERISTICS Model Name AGG09LVCB AGG12LVCB AGG14LVCB Voltage 230 ~ Power Supply Frequency Max Operating Current Connection Cable *)Wiring Spec Limited wiring length *) Wiring Spec Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 18) -...
SAFETY DEVICES Model Protection form AGG09LVCB AGG12LVCB AGG14LVCB Circuit protection Current fuse (PCB) 250V 3.15A Terminal protection Current (thermal) fuse 250V 3A OFF: 150±15°C Fan motor protection Terminal protection program ON: 120±15°C - (01 - 19) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN14 Control input See external input/output CN20 Operation status output settings for details. CN21 Error status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 24
Parts (Optional) Parts name Model name External connect kit UTY-XWZXZ5 Wire (External input) : UTY-XWZXZ5 - (01 - 21) -...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply Relay spec.: 10m* Max.24V DC, 10mA to less than 500mA.
Page 26
ERROR STATUS OUTPUT An air conditioner error status signal can be output. Circuit diagram example Indoor unit Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply Relay spec.: 10m* Max.24V DC, 10mA to less than 500mA.
FUNCTION SETTINGS 12-1. INDOOR UNIT (Setting by remote controller) • This procedure changes to the function settings used to control the indoor unit according to the installation conditions. Incor settings can cause the indoor unit to malfunction. • After the power is turned on, perform the “FUNCTION SETTING” according to the installation conditions using the remote controller.
Page 28
FUNCTION DETAILS Functions Floor 1) Filter sign 2) Embedding the indoor unit in a wall 3) Cooler room temperature correction 4) Heater room temperature correction 5) Auto restart Indoor room temperature sensor switching function 7) Remote controller signal code 8) External input control 9) Indoor unit fan control for energy saving 1) Filter sign...
Page 29
2) Embedding the indoor unit in a wall When embedding the indoor unit in a wall, restrict the movement of the horizontal vane for the upper air outlet so that it only operates horizontally. ( ... Factory setting) Setting description Function number Setting value ...
Page 30
5) Auto restart Enable or disable automatic system restart after a power outage. ( ... Factory setting) Setting description Function number Setting value * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate using the remote controller, or external input device.
Page 31
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS 13-1. CONTROLLER Exterior Parts name Summary Model No. Large and full-dot liquid crystal Wired remote screen, wide and large keys UTY-RVN M controller easy to press, user-intuitive arrow key. The room temperature can be Wired remote controlled by detecting the UTY-RNN ...
Page 33
2. OUTDOOR UNIT SINGLE TYPE : AOG09LVCN AOG12LVCN AOG14LVCN DTR_AO094E_02 2013.01.21...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AOG09LVCN AOG12LVCN AOG14LVCN Power sourse 230V ~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current Cooling 2,050 2,355 Airflow rate Heating 2,000 Type×Q'ty Propeller fan×1 Motor output Cooling Sound pressure level dB(A) Heating Cooling Sound power level...
DIMENSIONS MODEL : AOG09LVCN, AOG12LVCN, AOG14LVCN (Unit : mm) Top view Side view Front view Air flow 17.5 hole (10) (10) (10) hole (6x20=120) (6x20=120) ø20 hole 4-ø11.3mm hole Bottom view INSTALLATION PLACE CAUTION In areas with heavy snowfall, if the intake and outlet of the outdoor unit is blocked with snow, it may be diffi- cult to warm up and likely to cause breakdown.
ELECTRIC CHARACTERISTICS Model name AOG09LVCN AOG12LVCN AOG14LVCN Voltage 230 ~ Power supply Frequency *1) Max operating current 11.5 14.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec.: Power Cable 3.5-4.0 *3) Limited wiring length : *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
SAFETY DEVICES Model Protection form AOG09LVCN AOG12LVCN AOG14LVCN Current fuse 250V 20A ― (NEAR THE TERMINAL) 250V 5A Circuit protection Current fuse 250V 15A 250V 5A (MAIN PRINTED CIRCUIT BOARD) 250V 3.15A 250V 3.15A Thermal protection OFF : 100±15°C Fan motor protection program ON : 95±10°C Thermal protection...