1.0 Specifications
• Range:
DS422i
300 ft. (90 m)
DS426i
600 ft. (180 m)
• Dimensions (HxWxD):
• Voltage:
• Current:
DS422i
DS426i
• Standby:
• Relay:
• Tamper:
• Pointability:
• Temperature:
• Trigger Response Time:50 to 700 milliseconds, selectable.
2.0 Installation Considerations
• Stay within the listed maximum range.
• Install the system with a clear line-of-sight between the transmitter
and receiver. If installed outdoors, make sure trees, weeds, plants,
etc. will not interfere with the beams.
• Use care when installing near reflective surfaces (i.e. glossy walls
or floors). Care should be taken during alignment to ensure beams
are line-of-sight aimed and are not reflecting off surfaces.
• Do not install the units where they may be immersed in water or
subject to corrosive liquids or sprays.
• Do not install the receivers where they will be facing an intense
source of light (e.g. a rising or setting sun). If the sun can not be
avoided, mount the receiver slightly higher than the transmitter. Aim
the receiver down at the transmitter.
• Do not install the receivers where sunlight could be reflected directly
into the receiver optics.
• Do not install either unit on movable surfaces or surfaces subject to
strong vibrations.
3.0 Mounting
3.1 Surface Mounting
NOTE: The recommended mounting height is 3 feet (1 m). However,
mounting height will change depending on the anticipated
intruder catch area.
• Choose the appropriate mounting locations. They should be rigid
and provide a clear line-of-sight between the transmitter and receiver.
• Remove the transmitter's cover by loosening the cover mounting
screw (see Figure A).
Indoors
Outdoors
100 ft. (30 m)
200 ft. (60 m)
6.75 in. x 3.25 in. x 3.5 in.
171 mm x 82 mm x 87 mm
12 to 28 VDC. Non-Polarized.
Transmitter
Receiver
15 mA
25 mA
30 mA
25 mA
Intended for connection to DC power
supplies capable of supplying power if
primary power fails.
Alarm activated Form "C" with dry
contacts rated at 0.5 amps max. @
30 VAC and DC.
Normally Closed with cover in place.
The optical module can be adjusted
±90° horizontally or ±24° vertically.
-13°F to +130°F (-25°C to +55°C).
Wire Entrance
GOOD
LEVEL ALARM
ACTIVE INFRARED SENSOR
Fine Tuning
Optical Module
Cover Screws
Receiver
Figure A - Location of the system's major items.
• Place the provided template onto the mounting surface and mark
the holes for its two mounting screws (supplied).
NOTE: Be sure all wiring is unpowered before routing.
• Route wiring (for wire size see Section 4.0) through the transmitter's
wire entrance, leaving enough to properly wire the transmitter.
• Mount the transmitter to the mounting surface. Firmly tighten the
screws.
• Repeat this complete mounting procedure for the receiver. Be sure
to mount the receiver in direct line-of-sight with the transmitter.
3.2 Pole Mounting
NOTE: The recommended mounting height is 3 feet (1 m). However,
mounting height will change depending on the anticipated
intruder catch area.
NOTE: Use optional MB series poles or equivalent.
• Choose the appropriate mounting location. Install the poles with a
clear line-of-sight between the transmitter and receiver.
• Remove the transmitter's cover by loosening the Cover Screw (see
Figure A).
• Firmly attach a mounting plate and U-clamp to the pole (see Figure
B) with the screws supplied. Make sure they are line-of-sight aimed
so the transmitter and receiver will be aligned.
Figure B - Pole assembly
Response
Adjustment
Power LED
POWER
Alignment
ACTIVE INFRARED SENSOR
Voltage
Jacks
Vertical
Screw
Alignment
Tool
Note: Tool
may be in
any of four
positions
Transmitter
W iring Entrance
U-clamp

Advertisement

loading

Summary of Contents for Bosch DS422I

  • Page 1: Installation Instructions

    Installation Instructions DS422i and DS426i Dual Beam Photoelectric Intrusion Detection Systems 1.0 Specifications • Range: Indoors DS422i 300 ft. (90 m) DS426i 600 ft. (180 m) • Dimensions (HxWxD): 6.75 in. x 3.25 in. x 3.5 in. 171 mm x 82 mm x 87 mm •...
  • Page 2 If more than one system is added to the run, the maximum length per gauge decreases and is determined by dividing the length found in the chart by the number of systems on the run. DS422i Wiring Chart SIZE 12 VDC 920 ft.
  • Page 3 ALARM LED nor the LEVEL LED should come on. • If necessary, re-align and fine-tune each unit. DS422i/426i Installation Instructions The system’s sensitivity to alarms is manually adjusted by the RESPONSE TIME Control on the receiver (see Figure L1 and Table L2).
  • Page 4 The only way to insure proper continual protection is to perform regular walk tests of the desired coverage area. Figure R- Perimeter protection Figure T - Close proximity field problem DS422i/DS426i Installation Instructions P/N: 44974D 03/04 Page 4...

This manual is also suitable for:

Ds426iSf8172Sf8172vSp-4c