Husqvarna DC 5500 Operator's Manual page 12

Hide thumbs Also See for DC 5500:
Table of Contents

Advertisement

Available languages

Available languages

Undo the filter link hose coupling.
Release the primary filter housing toggle latches and fold
down the silo.
Release the primary filter toggle latches.
LIft out the primary filter.
12 –
English
MAINTENANCE
Loosen the hose clamp screw at the base of each filter
sock with an 8 mm socket or a screw driver.
Remove the filter sock from the hose clamp tube. Take
care of the hose clamp end the clamp backing rubber.
Remove the cable ties using a wire cutter.
Dispose of the used sock filters.
Fitting new sock filters
Stretch the filter sock opening. Fit the filter sock over the
hose clamp tube.
Fit the backing rubber ring down over the filler sock
followed by the clamp. Be sure to have the clamp evenly
positioned in the middle of the protective backing rubber
ring.

Advertisement

Table of Contents
loading

Table of Contents