To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
A. Burner cap
B. Burner
2. Locate the Natural gas orifice spuds for top burners in the
literature bag included with the range. Three natural gas
spuds are stamped "149" and one "165."
3. Remove the LP gas orifice spuds using a 7 mm combination
wrench.
4. Install the Natural gas orifice spuds using a 7 mm
combination wrench.
A. Spud
B. Holder
NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and
1 super burner. Spud size and location remain the same.
For models with 4 standard burners:
A
B
For models with 3 standard burners and 1 super burner:
5. Place LP gas orifice spuds in the parts bag for future use and
keep with the bag containing literature.
6. Reinstall burners, burner caps and burner grates.
To Convert Oven Burner
A
1. Open the oven door and remove oven racks, oven tray, flame
spreader and set aside.
2. Lift oven burner. The orifice spud is behind the oven burner
air shutter.
B
Std Burner 149
Std Burner 149
Std Burner 149
Super Burner 165
A
A. Oven burner
B. Air shutter
Std Burner 149
Std Burner 149
Std Burner 149
Std Burner 149
B