COMPONENT ACCESS
Front Grille Components
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
Tools needed
¼" NUT DRIVER
T15
®
TORX
®†
T20
®
TORX
®†
T25
®
TORX
®†
STRAIGHT BLADE DRIVER
PHILLIPS HEAD DRIVER
NEEDLE NOSE PLIERS
CHANNEL LOCK PLIERS
VOM
NEEDLE POINT PROBES
NOTE: Needle point meter probes must be used for
checking voltages on electronic boards
†
®
®
®
- TORX
and T15
T20
T25
,
,
Intellectual Properties, LLC.
LEvELiNg LEgs
Ice Maker is equipped with 4 leveling legs. Level unit side
to side and front to back for uniform cube size.
BOTTOm Of machiNE cOmparTmENT BasE
4-2
n
®
are registered trademarks of Acument
FIGURE 1
accEss ThE waTEr vaLvE aNd TEch shEET
1. Unplug ice maker or disconnect power.
2. To access the water valve and tech sheet start by
removing the 4 screws holding grille. Pull out on the
bottom of the grill and then down. See Figure 2.
NOTE: It may be necessary to push back on the top of
the ice maker to drop and remove the front cover from
the hinge plate. Make sure the white divider is in place
to prevent condenser air bypass.
15 iNch
waTEr vaLvE
TEch shEET
rEmOviNg ThE waTEr vaLvE
3.
Remove the screw. See Figure 3.
18 iNch
FIGURE 2
FIGURE 3