Broadcast lance

Advertisement

6. use-Broadcast sprayer
6.1.
Broadcast Lance
6.1.1.
Move the broadcast lance into the broadcast position (fig.3).
6.1.2.
ensure the broadcast lance valve is in the oFF position (fig.4).
fig.4
6.2.
Broadcast nozzle
6.2.1.
If needed, rotate the broadcast nozzle so that the spray pattern is pointing down and evenly distributed. (fig.5)
6.2.2.
ensure gloves are worn when adjusting the lance and nozzle, as dripping may occur.
fig.6
6.3.
start spraying
6.3.1.
Turn the remote switch to on (I).
6.3.2.
Turn the broadcast lance valve on (fig.6).
6.3.3.
To ensure a uniform spray pattern, overlap each spray 300mm (fig.7).
6.3.4.
See the speed/application tables to determine the speed for the ATV.
note!
refer to the manual for ss37 for maintenance and storage instructions.
7. trouBLesHootInG
SYMPToMS
ReASon
Pump will not
1. Poor electrical
start.
connection.
2. Short in wires
3. low voltage.
low pressure.
1. Worn spray gun
nozzle.
2. Worn boom
nozzle.
Low flow.
1. Clogged intake
tube.
2. Clogged suction
strainer.
3. low voltage.
Poor spray
1. Clogged intake
distribution.
tube.
2. Clogged suction
strainer.
3. Worn spray gun
nozzle
Pump
1. leak in the
operates while
system
not spraying.
© Jack Sealey limited
ReMedY
1. ensure good connections.
2. Check conditions of wires.
3. Check the battery voltage.
1. Replace spray gun nozzle.
2. Replace boom nozzle.
1. Remove obstruction to
intake tube.
2. Clean suction strainer.
3. Check the battery voltage.
1. Remove obstruction to
intake tube.
2. Clean suction strainer.
3. Replace spray gun nozzle.
1. Find leak and tighten hose
clamps or fittings.
Replace spray gun.