Mitsubishi Electric 800 Series Instruction Manual page 61

575v class, compact, high functionality inverters, 0.75k-7.5k
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Operation of the SAFE and SAFE2 signals
E.SAF
Status of safety
*3
indication
related parts
Not displayed
Normal
Displayed
Fault
*1
If any of the faults shown in the following table occurs, the SAFE signal and the SAFE2 signal are turned OFF.
Fault type
Option Fault
Communication option error
Parameter storage device fault (control
circuit board)
Retry count excess
Parameter storage device fault (main
circuit board)
Safety circuit fault
*2
When safety communication functions are enabled (Pr.S002 ≠ "0"), the STO function is enabled while the safety communication is not
established.
*3
If another fault occurs when the fault E.SAF occurs, the other fault indication may be displayed.
*4
If another warning occurs when the warning SA occurs, the other warning indication may be displayed.
*5
The ON/OFF state of the output signal is the one for the positive logic. In negative logic, the signal status is opposite.
*6
To assign the functions of the SAFE signal and SAFE2 signal to output terminals, set either value shown in the following table in Pr.192 ABC
terminal function selection. To output the signal via communication, the function can be assigned also to Pr.190 to Pr.196 (Output terminal
function selection) using communication protocols. For details, refer to the Instruction Manual (Communication) or the Instruction Manual of
each communication option.
Output signal
SAFE
SAFE2
*7
The use of the SAFE signal and SAFE2 signal has not been certified for compliance with safety standards.
For details, refer to the FR-E800-SCE Instruction Manual (Functional Safety).
60
2. Installation and Wiring
2.6 Control circuit
STO function status when
the STO or SS1 command
is input
STO disabled
*2
STO disabled
Operation panel
indication
E.OPT
E.OP1
E.PE
E.RET
E.PE2
E.SAF
Pr.190 to Pr.196 setting
Positive logic
80
81
Inverter operating status
Operation enabled
Output shutoff (Safe state) Displayed
Output shutoff (Safe state) Not displayed OFF
Fault type
Overspeed occurrence
Speed deviation excess detection
Brake sequence fault
CPU fault
Internal circuit fault
Negative logic
180
181
Output signal
SA
*4
indication
SAFE
Not displayed OFF
*1
ON
Operation panel
indication
E.OS
E.OSD
E.MB4 to E.MB7
E.CPU
E.5 to E.7
E.13
*5*6*7
SAFE2
*1
ON
*1
ON
OFF