Troubleshooting - Husqvarna WT2GO Operator's Manual

Constant pressure water supply unit
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
Pump does not fill
Irregular variations in
pressure
Pressure drop
Water leaking from main
housing
WT2GO - User Manual
TROUBLE SHOOTING GUIDE
CAUSE
Valve faulty
Blockage in hose
Blockage in top cap
Machine being used has
blockage
Valves blocked by debris
Air in system
Hose blocked by debris
Tank empty
Blockage in hose
Faulty valve
Ruptured bladder
Cracked housing
Water accumulated whilst
stowed on side
REMEDY
Inspect valve on hose
Remove hose from WT2GO and
flush with tap water from either end
Check for blockages at barbed
fittings
Inspect inlet for debris
Refer to applicable machine's
operator manual
Clean the valves
Follow instructions on device to fill
from empty
Remove hose from WT2GO and
flush with tap water from either end
Fill following procedure in manual/
and on WT2GO
Remove hose from WT2GO and
flush with tap water from either end
Inspect valves for blockages/damage
Contact your servicing dealer
Contact your servicing dealer
When stowed on side or upside-
down water can accumulate in upper
housing. This is normal do not
confuse with leaking.
Page 11 of 15