en | Network
Network MSS (Byte)
You can set the maximum segment size for the IP packet's user data. This gives you the option
to adjust the size of the data packets to the network environment and to optimize data
transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.
iSCSI MSS (Byte)
You can specify a higher MSS value for a connection to the iSCSI system than for the other
data traffic via the network. The potential value depends on the network structure. A higher
value is only useful if the iSCSI system is located in the same subnet as the camera.
Network MTU [Byte]
Specify a maximum value in bytes for the package size (including IP header) to optimize data
transmission.
8.3

Advanced

The settings on this page are used to implement advanced settings for the network.
Operation
RTSP
RTSP port
If necessary, select a different port for the exchange of the Real Time Streaming Protocol
(RTSP) data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP
function.
Authentication
If a RADIUS server is employed in the network for managing access rights, authentication must
be activated here to allow communication with the unit. The RADIUS server must also contain
the corresponding data.
To configure the unit, you must connect the camera directly to a computer using a network
cable. This is because communication via the network is not enabled until the Identity and
Password parameters have been set and successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying the camera.
Password
Enter the password that is stored in the RADIUS server.
Password [EAP-MD5]
Enter the password that is stored in the RADIUS server.
Certificates [EAP-TLS]
If any certificates are already uploaded at the client level or at the server level, they show
here.
NTCIP
Specifies a set of rules and protocols for organizing, describing and exchanging transportation
management information between transportation management applications and
transportation equipment such that they interoperate with each other.
Select a port for NTCIP as well as the Address from the appropriate drop-down lists.
Note: The NTCIP section appears only for cameras with an NTCIP license.
2020-11 | 1.4 |
10 Mbps HD (half duplex)
10 Mbps FD (full duplex)
100 Mbps HD (half duplex)
100 Mbps FD (full duplex)
User Manual
MIC IP ultra 7100i │ MIC IP starlight 7100i
Bosch Security Systems