Smoke Alarm
Mounting the base
Mount the base with one central screw and plug. (5.A), or
optionally use two screws and plugs. (5.B) To set the device into
operation you screw the detector head to its base by twisting it
clockwise until it latches. (6)

4 Maintenance

Functional check
A visual inspection and a functional check must be performed for
each device monthly. After the functional check the device is
muted for 10 min, even when an alarm will be triggered. After
10 min the device will switch to normal mode again.
The device is in normal mode (no signal). To perform the
functional check press and release the button (< 2 s). (6) ->
Siren sounds 3 times ≥85 dB(A).
If the functional check fails the device is defective and must be
replaced.
Siren off (alarm signal)
If you press and release the button (< 2 s) of a device that has
triggered an alarm, then the device stops sounding. After 10 min
the device will switch to normal mode again.
Battery replacement
If the siren sounds short every 43 s (weak battery) you have to
replace the batteries.
1. Remove the head and insert new FUJITSU LR6 G or GASSNER
LR6 batteries in the battery compartments, observing the
polarity shown. (6.1)
Bosch Sicherheitssysteme GmbH
Graphics | en
08.15 | 3.1 | F.01U.309.848