Download Print this page

Pioneer 2GB250 Installation Manual page 6

Single handle kitchen faucet

Advertisement

To Set or Adjust Temperature Limit Stop
Caution: Valve is preset at the factory test at maximum. Adjust as neces-
sary. Please see the instructions below:
Turn off main supply stop and relieve the pressure.
Remove handle(M) by loosening set screw(N) lift off the handle.
Unscrew retainer ring(O) and locknut(P) counterclockwise.
Use two fingers to raise the red adjusting ring(Q).
Turn adjustment ring counterclockwise to decrease the temperature
setting and clockwise to increase the temperature. Replace adjust-
ing ring.
Reassemble and test until desired safe temperature is reached.
(Note: Ensure proper alignment of cartridge with notch in faucet
body.)
For more care information or trouble shooting inquiries about your
Pioneer product, please see the contact information on the back page.
6
REV-01 25, 13

Advertisement

loading

This manual is also suitable for:

2cl2502mt2502lg250