Download Print this page

Mitsubishi Electric 700 Series Installation Manualline page 22

Hide thumbs Also See for 700 Series:

Advertisement

Pr.
Name
Reference value at
62
acceleration
Reference value at
63
deceleration
65
Retry selection
Stall prevention operation
66
reduction starting frequency
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Special regenerative brake
70
duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected
75
PU detection/PU stop
selection
77
Parameter write selection
Reverse rotation prevention
78
selection
79 Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
Speed control gain (Advanced
89
magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
96
Auto tuning setting/status
PU communication station
117
number
118
PU communication speed
PU communication stop bit
119
length
PU communication parity
120
check
Number of PU communication
121
retries
PU communication check time
122
interval
PU communication waiting
123
time setting
PU communication CR/LF
124
selection
Terminal 2 frequency setting
125
gain frequency
Initial
Setting Range
Value
0 to 200%, 9999
9999
0 to 200%, 9999
9999
0 to 5
0
0 to 400Hz
60Hz
0 to 10, 101 to
0
110
0.1 to 360s
1s
0
0
0 to 30%
0%
0, 1, 3 to 6, 13 to
16, 23, 24, 40,
0
43, 44, 50, 53,
54
0 to 15
1
0, 1, 10, 11
1
0 to 8
1
0 to 3, 14 to 17
14
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4, 6, 7
0
0.1 to 15kW,
9999
9999
2, 4, 6, 8, 10,
9999
9999
0 to 500A, 9999
9999
∗4
200V/
0 to 1000V
400V
∗6
10 to 120Hz
60Hz
0 to 200%, 9999
9999
0 to 50Ω, 9999
9999
∗4
0 to 50Ω, 9999
9999
∗4
0 to 1000mH,
9999
9999
∗4
0 to 1000mH,
9999
9999
∗4
0 to 100%, 9999
9999
∗4
0, 1, 11, 21
0
0 to 31 (0 to 247)
0
48, 96, 192, 384
192
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0, 0.1 to 999.8s,
0
9999
0 to 150ms,
9999
9999
0, 1, 2
1
0 to 400Hz
60Hz
Pr.
Name
Terminal 4 frequency setting
126
gain frequency
PID control automatic
127
switchover frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection 0 to 7
146
Parameter for manufacturer setting. Do not set.
Acceleration/deceleration time
147
switching frequency
150
Output current detection level
Output current detection signal
151
delay time
152
Zero current detection level
153
Zero current detection time
Stall prevention operation
156
selection
157
OL signal output timer
158
AM terminal function selection
160 User group read selection
Frequency setting/key lock
161
operation selection
Automatic restart after
162
instantaneous power failure
selection
Stall prevention operation level
165
for restart
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/
172
batch clear
173
User group registration
174
User group clear
178
STF terminal function selection
STR terminal function
179
selection
PARAMETER LIST
Initial
Setting Range
Value
0 to 400Hz
60Hz
0 to 400Hz, 9999
9999
0, 20, 21, 40 to
43, 50, 51, 60,
61
0.1 to 1000%,
100%
9999
0.1 to 3600s,
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0.01 to 10.00s,
9999
9999
0 to 400Hz, 9999
9999
0 to 200%
150%
0 to 10s
0 to 200%
5%
0 to 1s
0.5s
0 to 31, 100, 101
0 to 25s, 9999
1 to 3, 5, 7 to 12,
14, 21, 24, 52,
53, 61, 62
0, 1, 9999
0, 1, 10, 11
0, 1, 10, 11
0 to 200%
150%
0, 10, 9999
9999
0, 9999
9999
9999, (0 to 16)
0 to 999, 9999
9999
0 to 999, 9999
9999
0 to 5, 7, 8, 10,
12, 14 to 16, 18,
24, 25, 60, 62,
65 to 67, 9999
0 to 5, 7, 8, 10,
12, 14 to 16, 18,
24, 25, 61, 62,
65 to 67, 9999
0
1s
1
0s
0
0s
1
0
0
1
0
60
61
19

Hide quick links:

Advertisement

loading