Download Print this page
Sealey GA45 Instructions

Sealey GA45 Instructions

Camber/castor magnetic gauge

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this
p
equipment.
3 Maintain the gauge in good condition (use an authorised service agent).
3 Replace or repair damaged parts.
WARNING! Use the gauge on level and solid ground.
p
7 DO NOT allow untrained persons to use the gauge.
WARNING! When setting front-end alignment on commercial vehicles never make adjustments to drop arms or interconnecting
p
links. Doing so could result in serious tyre, wheel and steering problems.
3 Any alignment changes deemed necessary as a result of using this equipment must be made strictly in accordance with the
vehicle manufacturer’s recommendations.
2.
INTRODUCTION & SPECIFICATION
Robust, magnetic gauge mounts onto hub or brake disc for quick and accurate measurement of camber and castor angles. Large
adjuster knob for convenient zeroing of bubble during castor angle measurement. Graduated from +6° to -6°.
3.
MEASURING CAMBER ANGLE
NOTE:
Before proceeding to check the camber, first calibrate your gauge using one of the following methods:
a. Clamp a good quality spirit level, with transverse bubble, so that the long faces are vertical.
Place the magnetic face of the gauge onto the vertical face of the spirit level and adjust the gauge thumbscrew until
the gauge bubble is centred on the 0° mark.
b. Use a known true vertical surface to place the gauge against and adjust the bubble to zero.
NOTE:
You must have a flat machined surface at 90° to the spindle in order to use this gauge. If using the brake discs ensure
there are no ridges and that the discs have even wear. Preferably use new discs.
3.1
To Check Camber With Wheels On.
3.1.1
Ensure your vehicle is parked on a flat level surface, the tyres are inflated to the correct pressure and the rear wheels
are chocked.
3.1.2
Having removed any wheel trims, place a straight bar across two flats of the wheel trying to keep as close to the 6
o’clock position as possible (Fig. 1). Ensure the wheel has no dents where you are placing the bar.
INSTRUCTIONS FOR:
CAMBER/CASTOR MAGNETIC GAUGE
GA45
Model No:
GA45 - 1 - 220805

Advertisement

loading

Summary of Contents for Sealey GA45

  • Page 1 GA45 Model No: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.