Transfer/separation corotron assembly:
1.
Remove the protective grid A by pushing the 4 tabs. Remove the terminals protective covers B.
Using a vacuum cleaner and a soft brush clean the inside of the assembly, especially the
terminals. Be careful not to tear the corotron wires. After you have removed the toner and
developer deposits clean thoroughly usin cotton swabs dipped in window cleaner fluid. From
my experience this is the only efficient cleaning agent for this type of dirt deposits. See figure
19.
B
A
19