Mitsubishi Electric GOT1000 Series Quick Start Manual page 5

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:

Advertisement

2
Restore the system as soon as possible
Operation halts due to unknown reasons at an unknown location.
Using  the  One-Touch  Ladder  Jump  Function  in  combination  with 
operation flow diagrams helps you quickly search the problems cause.
【Benefit】
During automatic operation, the process may stop without any warning alarms 
(e.g.  sensor  positioning  error).  when  this  occurs,  just  touch  the  operation  flow 
diagram  which  will  show  you  the  root  cause  of  the  problem.  Since  there  is  no 
need  to  use  personal  computers  or  ladder  programs,  the  downtime  of  the 
system is reduced.
Automatic operation flow diagram
All home position (M50)
Lifter down (M55)
Lifter down (M51)
Manual open (M56)
Manual close (M52)
Lifter up (M57)
Lifter up (M53)
Feed-backward (M58)
Feed-forward (M54)
Touch
During automatic operation, if the 
operation stops at a certain place, 
touch  the  operation  block  to 
display the relevant ladder block.
3
Find out the cause of the problem
The machine needs to be moved manually, but it does not work.
Just touch the screen to display the interlock status while in manual 
operation mode.
【Benefit】
When  manually  restoring  the  system  after  tooling  change  or  emergency  stop, 
just  press  a  switch  to  check  the  interlock  status.  This  also  reduces  the 
downtime.
Manual operation screen
Lifter up
(M80)
Lifter down
(M81)
If lifter down does not work due to the 
interlock,  press  I/L  display  touch 
switch to check the I/L ladder block of 
the lifter down operation.
Operation guard
<How to draw the flow diagram screen>
(1) Draw the screen for the automatic operation flow diagram. (to the left)
(2) Set internal devices in of the PLC automatic operation circuit (M50 to M58) to the 
〈Display M54 ladder block〉
Interlock doctor
<How to draw manual operation screen>
(1)  Put  "I/L  display"  switch  next  to  the  operation  switch  on  the  manual  operation 
I/L display
(2) Set internal devices for interlock of the relevant operation (M70, M71) to the I/L 
(M70)
〈Display interlock ladder block of lifter down〉
I/L display
(M71)
Touch
− 3 −
Supported software package: GT Designer2 Version 2.43V or later
Why's it
stopped ?
Hey, wake up and
lift the package !
touch switches of each operation block.
Lifter upper 
Lifter up
Lifter down
end X10
M53
M55
M54
M54
If lifter is up (M53 is on) but the operation 
does not move to Feed-forward (M54), the 
problem cause is the lifter upper end sensor 
(X10) which must have been on
・ ・ ・
It's in manual mode
but the machine doesn't
work . Why ?
screen. (to the left)
display switch.
Feed-forward 
Air pressure 
end X15
normal X08
M71
Feed-backward 
end X14
Air pressure is normal (X08 is on) but both 
feed-forward (X15) and feed-backward (X14) 
are off. To enable the operation (interlock 
(M71)), either one or both must be on.
Just touch here to
search the cause.
Feeding 
forward
Touch me, then
I will diagnose
your problem .
Lifter down 
I/L