Location and Function of Parts

1
Front panel
S
Rear panel
1 Indicator
Lights in green when this unit is turned on.
Flashes in red in the following cases:
• The temperature inside the unit has risen to a
specified level.
• The ventilation fans have stopped rotating.
• Trouble occurs with the output voltage on the
negative side.
May flash in green in the following cases:
• The rotation of the ventilation fans slows down
drastically.
• Until the rotation of the ventilation fans becomes
stable just after the power is turned on.
2 POWER switch
Turns on and off the power of this unit.
3 Cover plates
Remove the corresponding plates to install the optional
boards.
4 REF IN (reference signal) input connector (BNC
type)
When an optional board such as a BKPF-300-series
board that requires a reference signal input to the PFV-
D10 is installed, input an analog black burst signal as a
reference signal.
6 (E)
Indicator
2
POWER switch
POWER
I
O
3
Cover plates
DIGITAL VIDEO INTERFACE UNIT
4
REF IN connector
5
Loop-through output connector
6
REMOTE connector
REF IN
REMOTE
ROUTING SWITCHER
5 Loop-through output connector (BNC type)
The reference signal input to the REF IN connector is
supplied as it is. When this connector is not used,
connect a 75-ohm terminator.
6 REMOTE connector (BNC type)
For controlling a routing switcher, connect an S-BUS
line when an optional board such as a BKPF-300-
series board that requires an S-BUS protocol input to
the PFV-D10 is installed.
7 y (signal ground) terminal
For signal ground. Connect to a ground wire as
required.
8 ~AC IN connector
Connect to an AC power supply using a power cord
below:
Model available in North America:
DK-2401 AC Power Cord
Model available in the United Kingdom:
Parts No. 1-590-910-11
PFV-D10
⁄AC IN
y
8
~AC IN connector
7
y (signal ground) terminal