1-5-4. SE-934 Board
n
When replacing the SE-934 board, be sure to check
Section 2-2.
1. Remove the top panel assembly. (Refer to Section 1-4-1.)
2. Remove the two screws (BVTT3 x 6) and two screws
(PSW3 x 6), then place the heat sink block assembly
upward and hook it on the maintenance arm assembly.
PSW
3 x 6
BVTT
3 x 6
Heat sink
block assembly
3. Remove the screw, then remove the SE-934 board.
4. Disconnect the harness from the connector (CN421)
on the SE-934 board.
Harness
CN421
SE-934 board
BVTT3 x 6
5. Install the SE-934 board in the reverse order of steps 1
to 4.
1-6
Hook here
Maintenance
arm assembly
Heat sink block
assembly

1-6. Replacing the Main Parts

1-6-1. Ribbon Door Assembly

n
When removing the ribbon door assembly, be careful not
to damage the flexible flat cable.
1. Remove the cabinet. (Refer to Section 1-4.)
2. Open the ribbon door assembly.
3. Remove the two screws, then remove the paper eject
guide cover in the direction of the arrow.
4. Disconnect the flexible flat cable from the connector
(CN701) on the MA-168 board.
5. Remove the four flat clamps.
6. Remove the hook, then remove the ribbon door lock
cover.
Paper eject
guide cover
BVTT3 x 6
Flat clamps
Ribbon door
Hook
lock cover
BVTT3 x 6
Top chassis
Flexible flat cable
Flat clamp
CN701
MA-168
board
UP-DR200