INSTRUCTION MANUAL
Sensor & Wire-saving Link System S-LINK
PC/104 Bus S-LINK Control Board
SL-PC104
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 CMJE-SLPC104 No.0037-84V

Advertisement

loading

Summary of Contents for Panasonic SL-PC104

  • Page 1 INSTRUCTION MANUAL Sensor & Wire-saving Link System S-LINK PC/104 Bus S-LINK Control Board SL-PC104 © Panasonic Industrial Devices SUNX Co., Ltd. 2013 CMJE-SLPC104 No.0037-84V...
  • Page 2: Power Supply

    1. Introduction Thank you very much for using Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a con- venient place for quick reference. Never use this product in a device for personnel protection.
  • Page 3: Function Description

    1) S-LINK system terminal block cinnector Main cable and power supply of the S-LINK system are connected. The S-LINK system terminal block connector is connector type and it is possible to wire it after removing it from SL-PC104. View from wiring side Output...
  • Page 4 (ON = 1, OFF = 0) With the above setting, “I/O address 0300H to 031FH” is occupied. Notes: 1) I/O addresses are set in binary number. 2) In SL-PC104 VHW >0 î @  >0 î @  21  >/ î @...
  • Page 5: Mode Switch

    3) Mode switch Performs setting of the S-LINK system. I/O setting switches (I/O SET0 to 3) are for setting input / output. System address length setting switches (SA0 and SA1) are for setting system address length. Setting is read in only once when power is supplied to the computer. Changing the mode switch setting during operation is ineffective.
  • Page 6 4. Assignment of Computer [Assignment] Computer I/O address Assignment (hexadecimal) Bank change-over response register (HML) 0 Data Control board prod- S-LINK input / output Address where ER4 S-LINK unit connec- area uct information units (initial value) occurs tion address (HML) F (version, etc.) (HML + 1) 0 Flag...
  • Page 7  +0/  WR +0/ ) Relationship between “Computer I/O address” and “S-LINK address” Computer S-LINK address I/O address bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 (hexadecimal) (HML) 0 (HML) 1 (HML) 2 (HML) 3 (HML) 4...
  • Page 8  +0/    )ODJ It indicates the operating condition of the S-LINK system. Assignment &RQ¿UPDWLRQ RI FRPPXQLFDWLRQ IUDPH FRPSOHWLRQ (Output data communication completed with “0” after writing in “1” ) System set (1: Read condition of S-LINK unit connection) Unusable (= 0) Condition of S-LINK system communication (1: Communicating) ER4 (1: Wire disconnection or abnormal I/O unit)
  • Page 9  +0/    ,2 VHWXS RI 6/,1. It sets up or indicates the I/O assignment of S-LINK system. Immediately after power supply or reset of computer, it indicates the setup condition of the I/O setting switches (I/O SET0 to 3) of “3) Mode switch” of “3. Functional Description.” When setting is done by a program, I/Os can be set in units of 16.
  • Page 10  +0/    1XPEHU RI 6/,1. XQLWV ZKHUH (5 KDV RFFXUUHG It indicates the number of S-LINK units where ER4 has occurred. ER4 can be released (“0”) by switching on again either the S-LINK system side power supply 9 '& RU WKH 3& EXV SRZHU VXSSO\ FRPSXWHU SRZHU VXSSO\ DIWHU IDXOW UHFWL¿FDWLRQ  +0/    1XPEHU RI FRQQHFWHG 6/,1.
  • Page 11 16 points. 4) Read out error flag, status flag and error address, and display in hexadecimal number system. >3URJUDP@ ’ **************************************** ’ * SL-PC104 SAMPLE PROGRAM * ’ * H11. 12. 1 ’ **************************************** ’...
  • Page 12 3) For details, please refer to the “S-LINK Design Manual.” 4) It is necessary to load the driver program before using this board. Please refer to “Panasonic Industrial De- vices SUNX website (http://panasonic-electric-works.net/sunx)´ RU FRQWDFW RXU RI¿FH ,I \RX FDQQRW DFFHVV RXU ZHEVLWH SOHDVH FRQWDFW RXU VDOHV RI¿FH...
  • Page 13  'LPHQVLRQV 8QLW PP 5.1±0.1 7.62±0.1 6.4±0.1 5.1±0.2 8.9±0.2 (26.7) 85.2±0.2 31 × 2.54 = 78.74±0.1 80±0.2 90.2 73.7±0.2 102.6 19 × 2.54 = 48.26±0.1 19.2±0.2 63.5±0.2 4-3.2 spacer mounting holes 5.1±0.2 85.7±0.2 2-3.2 bracket mounting holes 95.9 24.25 11.1 7.6 11.1 23.3 10.7...