Download Print this page
Sealey GT117 Manual

Sealey GT117 Manual

Pneumatic glove tester

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instruction
manual
1. SAFETY
This item is intended for use in the regular testing required of high voltage
electricians protective gloves.
2.
INTRODUCTION
i
Pneumatic Glove Tester used to carry out a pressure test on electricians high
voltage gloves. Suitable for use with the Sealey HVG1000VL gloves.
Simple manual operation and supplied with two ring clamp seals.
3.
SPECIFICATION
i
Model no.: ................................................................... GT117
4. OPERATION
IMPORTANT: Before high voltage electricians protective gloves are used, they
should be visually checked, and also tested for air leakage. Any perforation or deterioration to the glove could result in injury or fatality
due to the wearer coming into contact with high voltage electricity.
4.1.
After carrying out a visual inspection of the high voltage glove, place the cuff end over the GT117 Glove Tester and secure it in place
using the rubber rings supplied.
4.2.
Using the plunger in the underside of the glove tester inflate the glove until it has sufficient pressure to remain upright and free from
creasing (fig.1).
NOTE: DO NOT over-inflate as damage to the glove may occur (see fig.2)
4.3.
Check the glove inflation after one minute. There should be no significant loss of pressure and the glove should have retained its
original inflated shape.
4.4.
Release the rubber securing ring and remove the glove.
NOTE: It is imperative for user safety that high voltage gloves are tested before use. It is the responsibility of the wearer to ensure the
gloves are in a sound condition and are the correct type for the work being carried out. Any glove that is defective must NOT be
used.
4.5.
If the item becomes soiled it should be cleaned as soon as possible with soap and water not exceeding 65
© Jack Sealey Limited
PNEUMATIC GLOVE TESTER
GT117
MODEL NO:
fig.1
Original Language Version
C and thoroughly dried.
0
fig.2
GT117
Issue 1 20/04/18

Advertisement

loading

Summary of Contents for Sealey GT117

  • Page 1 GT117 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...