2-6-3. Saving of DDC Data

1. Connect the power cord and set this unit to standby state.
2. Press the [I/O] button on this unit.
The lamp lights and the image is displayed.
3. Double-click QuickAccess3.exe to start the application.
4. Select a target model on the Model pull-down menu.
5. Select Read from Projector on the Read/Write pull-down menu.
6. Select DDC on the Data Type pull-down menu.
7. Click the [Next] button.
8. Click the [Browse...] button.
The file selection window is displayed.
9. Set the destination file for the obtained data as below.
DDC data for INPUT A: BPJ_WUXGA_Pixie_VGA_0_**.dat
DDC data for INPUT B: BPJ_WUXGA_Pixie_DVI_1_**.dat
DDC data for INPUT C: BPJ_WUXGA_Pixie_HDMI_2_**.dat
n
. The DDC data of INPUT D is the same as that of INPUT C.
. ** means version.
10. Click the [Next] button.
11. Select the serial port used for connecting PC on the Serial Port pull-down menu.
Upper line: Serial port number used for connecting PC
Lower line: 38400 (not selectable)
12. Click the [Next] button.
The window displaying the model name of this unit, serial number, and the file path of the destination
of the obtained data to save is displayed.
13. Click the [OK] button.
The saving starts. Completed is displayed after completed.
14. Disconnect the power cord from this unit.
15. Click the [Complete] button.