Beko Bcti36510 Quick Start Manual page 5

Induction hob g5 – tc flex slider
Hide thumbs Also See for Bcti36510:

Advertisement

Available languages

Available languages

INDUCTION HOB G5 – TC FLEX SLIDER
1. To detect the wrong breakdowns :
1-1 Connection to the electric network:
• Control the tightening of the screws of the connection box
• Control the section of the cables used (see manual of use)
• Control if the earth wire (green) is connected
1+2 = phase L1
4+5 = phase L2
3 = no connection
earth = obligatory
alimentation cable: advised with fasten terminal wires
tightening of the screws: either with torx N°20 (highly advised), or with a big
and punt screwdriver.
The control of the connection and of the tightening must be done before any
intervention in the hob.
A wrong tightening can be at the origin of a breakdown.
If a bridge is not made correctly or if a screw is wrong tightened, the following
symptoms can occur:
- either none « 8 » appears at the electric connection,
- or the « 8 » appear and then the error « E6 », that indicates a problem to the
connection box.
5/12
D45127-0
INDUCTION G5
Crée le 07/03/17
Modifié le
FR
GB
DE

Advertisement

loading

This manual is also suitable for:

8800183200