2) Installation frame type
10.4
44
.409
1.732
22
.866
• Panel cut-out dimensions
The standard panel cut-out is shown below.
Use the mounting frame (ATH3803) and the rubber packing (ATH3804).
(Only installation frame type.)
60 min.
2.362 min.
• Terminal layout and wiring diagrams
1) Standard type
Non voltage input type
Count input
1
2
3
4
W-R are connected internally.
2) Backlight type
Count input
+V
5
1
2
3
6
0V
44.8
1.764
54.4
2.142
5
48
.197
1.890
COUNTER
24
.945
RESET
7
Reset button
.276
+0.5
45
0
+.020
1.772
0
+0.5
22.2
0
+.020
.874
0
Reset input
Voltage input type
<When green>
0V
Reset input
+V
4
1
2
0V
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
• Panel mounting diagram
Mounting screws
(found on mounting frame)
Panel
(1 to 4.5mm
LC2H
• For connected installation (sealed installation)
(Only installation frame type.)
Notes) 1. Suitable installation panel thickness is 1 to 4.5 mm
2. Waterproofing will be lost when installing repeatedly (sealed installation).
Voltage input type
Count input
Reset input
+V
+V
1
2
3
4
0V
0V
Backlight
<When red>
+V
5
5
3
4
1
2
3
4
6
6
0V
+V
Mounting frame
ATH3803 (included)
37
1.457
.039 to .177inch
thickness)
+0.5
22.2
0
+.020
.874
0
A
+1.0
A=(48×n-2.5)
0
+.039
A=(1.890×n-.098)
0
Free voltage input type
Count input
or
1
2
Rubber gasket
ATH3804 (included)
.039 to .177
inch.
Reset input
3
4