Sony KDL-32CX525 Service Manual page 27

Lcd digital color tv az2-f chassis
Hide thumbs Also See for KDL-32CX525:
Table of Contents

Advertisement

Available languages

Available languages

2X Blink - Main Power Error
A loss of REG12V from the power supply triggers this protect
event. This symptom is usually remedied by replacing the power
supply board. If the error continues after the power supply board
is replaced, suspect excessive loading which is causing the power
supply to shut down. This is usually caused by a failure of the inverter
circuits. Unplug the inverter and turn the TV back on. If a 6X error is
displayed, the inverter (or LCD panel) must be replaced.
3X Blink- DC Regulator/Audio Error
The first thing to check when a 3X blink protection mode occurs is
the physical condition of the speakers and speaker connections. The
speakers should measure 8 ohms. Shorted speakers or connections
can cause a 3X blink protection mode.
If the speakers and connections check okay, then the defective
component is on the main board. Either an open F4200, defective
DC Regulator, or defective Audio amplifier will cause a 3X blink
protection mode which would require replacing the main board.
A defect on the Power Supply Board may also cause a 3X blink
protection mode and shut-off. Check the AU12V level at CN6704/pin
14. If 0V is measure before shut-off the power supply board needs
to be replaced.
5X Blink - TCON Error
A communications error with the timing control circuits (TCON) has
occurred. If the TCON is available for replacement, replace the
TCON. If the TCON is not available, the LCD panel must be replaced
since the TCON circuit is part of the LCD panel assembly. In rare
cases a loose or defective LVDS cable could also be the cause.
KDL-32CX525/40CX525
SECTION 4 - TROUBLESHOOTING
6X Blink - Backlight System Failure
If the inverter circuits fails to generate high voltage or one or more
of the backlight lamps fails to light, the television will shut down
and display this diagnostics error. Observing for the presence of
backlighting is crucial in determining which component is likely at
fault.
If the backlights turn on before the 6X shutdown occurs, it is safe
to assume that the inverter circuits are functioning and one of the
lamps failed to ignite. Replacing the LCD panel is necessary. If the
backlights never turn on before the 6X shutdown, the inverter has
failed. If the inverter is available for replacement, replace the inverter.
If the inverter is not available, replace the LCD Panel.
7X Blink - Temperature Failure
A digital thermometer IC located on the main board provides a
temperature reading of the chassis and LCD panel. If the temperature
exceeds a pre-determined point the TV will shut down. If this problem
occurs immediately at turn-on, the temperature sensing IC has failed
and replacing the main board is required. If this occurs after the TV
has been running for a while, check for ventilation issues that could
cause the TV to run hotter than normal.
22

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Kdl-40cx525Kdl-40cx527Kdl-32cx527

Table of Contents