General Maintenance, Motor, Maintenance Tools, Relays - Siemens S-40EXIT Instructions & Maintenance

Railroad highway crossing
Table of Contents

Advertisement

Model S-40EXIT gate mechanisms have self lubricating bearings on the main shaft, gear shafts and on
the auxiliary sidewalk arm shaft when so equipped. No lubrication is required.
Gears should be coated with a thin film of all temperature grease, such as Aeroshell 7, at 3 to 6 month intervals
depending on number of gate operations. Clean thoroughly and reapply grease every two years or when signs of
gear wear are evident.
Ensure that air vents are kept unobstructed and flexible conduit between the gate mechanism and the junction box
base is kept sealed.
Motor Shaft bearings are sealed with all-temperature grease and no lubrication is required. The brush pressure
should be between 10 and 16 ounces. Normally the brush pressure, as adjusted at the factory, will be retained within
proper limits throughout the long life of the brushes.
Required maintenance is to inspect the brushes and commutator annually and following a broken or fouled gate
arm condition that may have held the motor in stall. Clean a darkened commutator by holding a commutator
cleaning stone or non-metallic abrasive cloth to it while rotating the motor shaft. After cleaning, cycle the gate 2-
3 times to clear brushes, then wipe commutator with a lint free cloth. Brushes worn to less than 3/4" length should
be replaced.
Torque Wrench Kit (contents listed on page 12) - 070981-X
Maintenance Kit Complete-073112-3X (includes following items which can be ordered separately)
- Contact Forming Tool-073112
- Contact Setting Gage-073112-1
- Commutator Cleaning Tool-073112-2
- Contact Cleaning Strips (box of 12)-073000-15
- Tension Gage for Motor Brush Springs and Controller Contacts-073000-16
Torque Card - 070982-2
The relay panel assembly (page 18, item 63) contains the Maintenance Switch Relay K3 (top), the Power Down
Relay K2 (middle) and the Power Up Relay K1 (bottom). Up Control Relay K4 is mounted on the terminal bracket.
Gate-down control energizes the down-control relay to release the brake and make power-down drive. At 1
the power-down contact #7 opens to de-energize the relay and the motor; and to energize the brake for hold
down. Removing gate-down control drops relay K4 to energize the power-up circuit. At 90
contact #8 opens to de-energize the up relay and the motor; and to energize the brake.
Field adjustment of relays is not recommended. Relays failing to pick up at 9.0 volts or release at 2.5 volts require
replacement of the K4 relay or the relay panel assembly.
Relay
12VDC Std
24VDC Std
G
M
ENERAL
AINTENANCE
M
OTOR
M
T
AINTENANCE
R
ELAYS
Relay Specifications
Coil Resistance
Pick Up
33 Ohm
9.0V max.
132 Ohm
18.0 V max.
15
OOLS
Drop Away
2.5V min.
1.0V nominal
0