Siemens SIMATIC Ident RF622A ETSI Operating Instructions Manual page 14

Table of Contents

Advertisement

Integration into RF600 systems
4.2 Radiated power parameter assignment
Limitations in China
Note
Limitation of the radiated power (CMIIT)
RF600 systems that are put into operation in China must not exceed the following radiated
power with an RF622A antenna:
• 2000 mW ERP (or 33 dBm ERP)
Converted into EIRP: 3250 mW EIRP (or 35 dBm EIRP)
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
• Radiated power: ≤ 2000 mW ERP (or 33 dBm ERP)
Converted into EIRP: ≤ 3250 mW EIRP (or 35 dBm EIRP)
• Use of cable loss associated with the antenna cable.
Limitations in Japan
Note
Limitation of the radiated power (ARIB)
RF600 systems that are put into operation in Japan must not exceed the following radiated
power with an RF622A antenna:
• 500 mW EIRP (or 27 dBm EIRP) for operation with RF650R (ARIB STD-T107)
• 4000 mW EIRP (or 36 dBm EIRP) for operation with RF680R/RF685R (ARIB STD-T106)
The maximum permissible radiated power of the antenna cannot be reached or exceeded
due to the negative antenna gain.