– In some menu items you can switch a func-
tion on or off. To switch the function off,
press the left-hand arrow button (15) so
that <Off> is highlighted. To switch the
function on, press the right-hand arrow
button (11) so that <On> is highlighted. You
can also switch the function on and off in the
menu by pressing the save/send button (9).
– To switch to a parent menu, press the left-
hand function button (17) under the "Back"
symbol. The selected settings will be saved.
– To exit the <Main Menu> and return directly
to the home screen, press the right-hand
function button (10) under the house sym-
bol. The selected settings will be saved.
– To exit any menu and return to the home
screen, you can also press the measure
button (4). If this button is pressed once,
the selected settings will be saved but meas-
urement will not be initiated.
Measurement Submenu
<Emissivity Degree> (t)
A selection of saved emissivities is available for some of the
most common materials. To make the search easier, the val-
ues are combined into groups in the emissivity catalogue.
First select the relevant category and then choose the relev-
ant material in the <Material> menu item. The correspond-
ing emissivity is shown in the line beneath. If you know the
exact emissivity of the object being measured, you can also
set it as a numerical value in the <Emissivity Degree> menu
item.
If you frequently measure the same materials, you can enter
5 emissivities as favourites and quickly call them up via the
bar at the top (numbered from 1 to 5).
<Reflected Temp.> (t)
Setting this parameter can improve the accuracy of the
measuring result, especially with low-emissivity (= high-re-
flection) materials. In some situations (especially in indoor
areas), the reflected temperature corresponds to the ambi-
ent temperature. If there are objects with greatly deviating
temperatures close to highly reflective objects, this value
should be adjusted as the measurement may be affected.
<Tool> submenu
Call up the <Main Menu> and select the <Tool> submenu.
This contains the following menu items.
<Language>
In the <Language> menu, you can change the language of all
the indicators on the display.
<Time & Date>
To change the time and date shown on the display (a), call
up the <Time & Date> submenu. This submenu also allows
you to change the time and date format.
Bosch Power Tools
To exit the <Time & Date> submenu, press either the left
function button (17) to save the settings, or the right func-
tion button (10) to discard the changes.
<Unit>
In the <Unit> menu, you can choose whether the temperat-
ures are displayed in <°C> or <°F>.
<Laser>
In the <Laser> menu, you can switch on or off the measuring
tool laser. The laser acts as a boundary for the measured
area and should, therefore, only be deactivated in excep-
tional cases.
<Measuring Frame>
In the <Measuring Frame> menu, you can switch the meas-
uring frame (b) on the display on and off.
<Colour Scheme>
In the <Colour Scheme> menu, you can choose the colour
of the temperatures and other indicators on the display. The
setting will also be applied to saved screenshots.
<Shutdown Time>
In the <Shutdown Time> menu, you can specify after how
long the measuring tool will switch off automatically if you do
not press any buttons. You can also deactivate automatic
switch-off by selecting the <Never> setting. The shorter the
automatic switch-off time, the more energy you can save.
<Light Duration>
In the <Light Duration> menu, you can specify after how
long the display lighting will dim if you do not press any but-
tons on the measuring tool. You can also choose to have the
display lit permanently by selecting the <Always> setting.
The shorter the display illumination time, the more energy
you can save.
<Audio Signals>
In the <Audio Signals> menu, you can switch the surface
temperature alarm sound on and off.
<Delete All Images>
In the <Delete All Images> menu, you can delete all the files
in the internal memory at the same time. Press the right-
hand arrow button (11) for <More> to enter this submenu.
Then press either the right function button (10) to delete all
files or the left function button (17) to cancel the process.
<Tool Information>
For information about the measuring tool, call up the <Tool
Information> submenu. There you will find the serial num-
ber of the measuring tool and the installed software version.
<Factory Reset>
Under this menu item, you can reset the measuring tool to
factory settings and permanently delete all data. This may
take several minutes. Press the right-hand arrow
button (11) for <More> to enter this submenu. Then press
either the right function button (10) to delete all files or the
left function button (17) to cancel the process.