一 技术参数 /Technical Parameters
外形尺寸/Dimensions
容积/Volume
重量/Weight
功率/Power
输入电压/Input Voltage
频率/Frequency
熔断保护/Fuse Protection
消毒方式/Disinfection Method
工作温度范围/Operating Temperature Range
存放温度范围/Storage Temperature Range
环境湿度范围/Ambient Humidity Range
紫外线风险组/UV Risk Group
二 结构示意图/Structure
三 产品安装 /Product Installation
 安装前的准备与检查/Preparation and inspection before installation:
1.安装位置必须距离燃气具、电热器具或其它热源30厘米以上或用隔板隔开。
The installation position must be more than 30cm away from gas appliances, electric heating appliances or other heat sources,
or separated by board.
2.安装前必须检查安装部位的强度与表面平整度,不得造成柜门的歪斜和错位。
Before installation, the strength and surface flatness of the installation place must be checked, and the skew and dislocation of
the chamber door should not appear.
3.应安装于能够承受柜体重量的地方。
It should be installed in the place that can bear the weight of the chamber.
4.安装时仔细检查其他可能导致机器不能可靠固定的因素,防止意外发生。
When installing, carefully check other factors that may cause the chamber to have malfunctions or
5.冲击电流约为5安培,请考虑电气容量。
Impulse current is about 5 amperes, please check electrical capacity.
6.安装时请充分考虑柜门能够完全打开的操作空间。
When installing, please fully consider the operating space that the chamber door can be fully opened.
型号描述/Model
执行标准/Standard:GB4706.1 / IEC60335-1
五. 注意事项/Precautions · · · · · · · · · · · · · · · 3
六. 维护与保养/Maintenance · · · · · · · · · · · · · 4
七. 故障处理/Troubleshooting · · · · · · · · · · · · 4
八. 环保清单/Environmental protection list · · 4
UVCC200 80W
560*560*660mm
110L
22kg
80W
220-240V~
50/60Hz
5A,250V~
253.7 nm 紫外线/UVC
10-40°C
-20-60°C
10%-90%
消毒柜内紫外线危险组别为RG3,
柜体外部为RG0/The risk group of
ultraviolet radiation in the
disinfection cabinet is RG3, and the
outside of the cabinet is RG0
accidents.

Advertisement

loading

Summary of Contents for Philips UVCC200 80W

  • Page 1 UVCC200 80W UVC Disinfection Chamber Instruction 目录/Contents: 执行标准/Standard:GB4706.1 / IEC60335-1 五. 注意事项/Precautions · · · · · · · · · · · · · · · 3 一. 技术参数/Technical Parameters· · · · 1 六. 维护与保养/Maintenance · · · · · · · · · · · · · 4 二.
  • Page 2  警告/Warning: 柜体安装固定示意图/Diagram of cabinet installation and fixation 1.请可靠接地,避免接地不良会 造成触电引发意外事故/Please ground reliably so as not to cause electrical shock accidents caused by poor grounding. 2.应由有资格的电工安装,接线 要符合IEE电气标准或当地的特殊 要求/It should be installed by country’s certified electrician, and the wiring should meet the IEE electrical standard or local special requirements.
  • Page 3 9.禁止硬物撞击紫外线灯管及其护罩/Hard objects are prohibited to collide with the UV lamp tube and its shade. 10.如果紫外线灯管损坏,必须更换飞利浦牌灯管(TUV 16W FAM/10X25BOX)/If the UV lamp is damaged, it must be replaced with the Philips lamp tube.(TUV 16W FAM/10X25BOX). 11.请单独使用额定电流5A以上有可靠接地线的插座/Please use the socket with rated current above 5A and with reliable grounding wire.
  • Page 4 15.请勿私自拆卸修理,必须由制造商或其维修部门等类似专业人员来修理/ Do not disassemble and repair without permission. It must be repaired by the manufacturer or its maintenance department and other similar professionals. 16.请勿将消毒柜浸泡在水中或对消毒柜喷水/Do not immerse the disinfection chamber in water or spray water on it. 六 维护与保养/Maintenance •不要对柜体喷水/Do not spray water on the chamber. •灯座附近严禁进水/Do not let water in the vicinity of lamp holder.