Wrong
22 | 64
Right
Description / explanation
Deflecting surface!
In the case of direct drainage from the compressed gas
line a deflection of the compressed gas flow is necessary!
Continuous slope!
If a pressure hose is used for inflow, avoid the formation
of a water pocket!
Continuous slope!
When laying pipes for the feed line, avoid the formation of
a water pocket.
Continuous slope!
Lay the condensate inlet line with a continuous slope! If
the installation height is limited, mount the lower inlet
with a separate venting line.
Ensure sufficient venting!
Large condensate quantities require installation of a
separate venting line.
Note the minimum height of installation!
The height of the condensate inlet must be located lower
than the lowest point of the collecting tank (e.g. vessel).
Original installation and operation manual