Siemens SIMATIC IFP2200 Product Information page 31

Hide thumbs Also See for SIMATIC IFP2200:
Table of Contents

Advertisement

Available languages

Available languages

Mechanical ambient conditions
The mechanical ambient conditions for the device and the Transceiver Unit are specified in the table below in terms of
sinusoidal vibration.
Device type
Vibration according to IEC 60068-2-6
Shock pulses within the specified range can be transferred to the display but do not impact the functionality of the device.
The table below provides information on the type and scope of tests for mechanical ambient conditions.
Tested
Test standard
for
Vibration
Vibration test in accordance with IEC 60068, Part 2-6 (sine)
s
Vibration duration: Ten frequency cycles per axis in each of
the three mutually vertical axes
Type of vibration: Frequency cycles at a rate of change of 1
octave/minute.
Shock
Shock test in accordance with IEC 60068, Part 2-27
Reducing vibration and shock
If the device is subjected to heavy shocks or vibrations, you must take appropriate measures to reduce acceleration or
amplitude during installation.
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the device.
Ambient conditions
Temperature, vertical mounting:
Temperature, inclined mounting
Transceiver Unit temperature
Relative humidity
Atmospheric pressure
Pollutant concentration
see section Permitted mounting positions (Page 19)
1
Note
Internal temperature of the enclosure
When the device is mounted, the internal temperature of the enclosure must not exceed 55 °C.
System components
All other system components connected to the device, such as the power supply, must also be suited to the respective
operating conditions.
SIMATIC IFP2200/2400 ITC2200/2400 frameless
A5E48015893-AC, 03/2021
Frequency range f in Hz
5 Hz ≤ f ≤ 8.4 Hz (3.5 mm)
8.4 Hz ≤ f ≤ 200 Hz (9.8 m/s
Permitted range
0 ... 45 °C (landscape format)
0 ... 40 °C (portrait format)
0 ... 40 °C (landscape format)
1
0 ... 35 °C (portrait format)
0 ... 50 °C
10% to 90%, without condensation
1140 to 795 hPa
SO
: < 0.5 ppm;
2
relative humidity < 60%, no condensation at
the rear of the device
H
S: < 0.1 ppm;
2
Relative humidity < 60%, no condensation at
the rear of the device
Comment
Mechanical class 3
)
see table below
2
Comments
Mechanical class 3:
5 Hz ≤ f ≤ 8.4 Hz, constant amplitude 3.5 mm
8.4 Hz ≤ f ≤ 200 Hz, constant acceleration 9.8 m/s
Type of shock: Half-sine
Severity of shock: Peak value 15 g, duration 11 ms
Direction of shock: 3 shocks in ± direction of axis in
each of the three axes vertical to each other
Comments
Inclination: Maximum 35°
vertical, interfaces facing downward
Corresponds to an elevation
of -1000 to 2000 m
Test: 10 cm
Test: 1 cm
/m
; 21 days
3
3
/m
; 21 days
3
3
2