The set-up should now look like this:
Apply a 942.667 MHz (channel 38 + 67.710kHz offset) -55 dBm signal to the RF-connector.
Measuring with an oscilloscope on "RXIP" or "RXQP" this picture should be seen on a working EGSM
receiver:
Signal amplitude
~550mV
DC offset
1,2V
Frequency
67kHz
If this picture is not seen go to section Fault finding chart for EGSM receiver of this document