1. Introduction ............................................................................................................................... 2
2. Overview of the System............................................................................................................ 2
3. Necessary equipment and software ......................................................................................... 2
4. Operating Environment and Installation.................................................................................... 3
5. Serial Port Setup File Format ................................................................................................... 4
6. How to Use the GP Setting Tool............................................................................................... 5
7. Errors ...................................................................................................................................... 12

Advertisement

loading

Summary of Contents for Toshiba TCS-NET

  • Page 1: Table Of Contents

    TCS-NET GENERAL PURPOSE INTERFACE Setting Tool Manual For advanced conjunction function Model name: TCS-NET General Purpose Interface TCB-IFCG1TLE (TCB-IFCG2TLE) Contents 1. Introduction ..........................2 2. Overview of the System......................2 3. Necessary equipment and software ..................2 4. Operating Environment and Installation..................3 5.
  • Page 2: Introduction

    Setting Tool Manual TCS-NET General Purpose Interface 1. Introduction This manual describes how to use the setting tool software for the advanced conjunction function for the general purpose interface. The setting tool allows writing, reading, and erasing air conditioning control data to respond to input port changes for the general purpose I/F board (TCB-IFCG1TLE, referred to as GP hereinafter).
  • Page 3: Operating Environment And Installation

    Setting Tool Manual TCS-NET General Purpose Interface 4. Operating Environment and Installation 4-1. Operating Environment Supported OS: Windows XP / 2000 Microsoft .NET Framework 2.0 or higher and a serial port are necessary to operate this system. 4-2. Required Files and Installation •...
  • Page 4: Serial Port Setup File Format

    Setting Tool Manual TCS-NET General Purpose Interface 5. Serial Port Setup File Format The COM port and timeout period settings can be changed with the setup file “serialPort.txt”. However, even if the settings are changed after startup, the setting change is not reflected because these settings are made during system startup.
  • Page 5: How To Use The Gp Setting Tool

    Setting Tool Manual TCS-NET General Purpose Interface 6. How to Use the GP Setting Tool 6-1. Startup Start the GPSettingTool.exe.
  • Page 6 Setting Tool Manual TCS-NET General Purpose Interface 6-2. Write Operation The set data of the selected patterns can be written to the GP. The set data of other patterns in the GP remains unchanged when the set data of the selected patterns is written.
  • Page 7 Setting Tool Manual TCS-NET General Purpose Interface 6-2-2. Setting Trigger Port and Condition Select the tab of the selected pattern to set Trigger Port and Condition. If no Trigger Port is selected, an error occurs. When selecting values for Condition, if the same value is selected for before and after (e.g. before = H, after = H), an error occurs.
  • Page 8 Setting Tool Manual TCS-NET General Purpose Interface 6-2-3. Setting Relay CH and Air Conditioning Control Data The following items can be set for air conditioning control data. • On/OFF • Operating mode • Set temperature • Fan speed • Disabling of remote control (ON/OFF only) Each central control address (1 to 64) can be set individually, and all addresses (1 to 64) can also be set collectively with the All button.
  • Page 9 Setting Tool Manual TCS-NET General Purpose Interface 6-2-4. Writing Set Data After all data have been set, click the Write button. A confirmation message appears. Confirm the message and click the OK button to send the set data. To cancel the write operation, click the Cancel button.
  • Page 10 Setting Tool Manual TCS-NET General Purpose Interface 6-3. Read Operation When the set data of the selected pattern is stored in the GP, the data can be read and displayed on the window. During this read operation, only the data of the selected pattern is displayed and the display contents of other patterns on the window are completely cleared.
  • Page 11 Setting Tool Manual TCS-NET General Purpose Interface 6-4. Erase Operation The set data of the selected patterns, which is stored in the GP can be erased with the Erase button. The set data of other patterns in the GP is not erased when the set data of the selected patterns is erased.
  • Page 12: Errors

    • COM port setting • Timeout period setting If this error still occurs after these connections and settings are checked, contact Global Sales Division /Engineering Consultant Group of Toshiba Carrier Corporation. 7-2. System Errors If normal operation is prevented due to the following errors, contact Global Sales Division /Engineering Consultant Group of Toshiba Carrier Corporation.