Download Print this page
Mitsubishi Electric P-RCC-E Installation Manual

Mitsubishi Electric P-RCC-E Installation Manual

Lossnay heat recovery ventilator system component rc cover

Advertisement

Quick Links

LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT
RC COVER
MODEL
P-RCC-E
Installation Manual
■ This product is for residential use.
■ This RC COVER is used to cover the space when the remote controller is removed from the Lossnay unit. Do not use this product for
any other purpose. Doing so may cause malfunction.
■ Proper installation is necessary for the product to perform at full potential and to ensure safety. Before installation, be sure to read
this manual.
■ Make sure to use accessory parts/designated parts for the installation parts. Using parts other than our designated parts may cause
malfunction.
■ Installation must be performed by dealers and electrical contractors. Incorrect installation can lead to malfunctions and accidents.
Installation by the customer can lead to malfunctions and accidents.
■ Electrical work must be done by a qualified and licensed electrician employed by the dealer or contractor.
After completing the installation, make sure to give this manual to the customer.
1. Safety precautions
Hazards created by mishandling and their severity are indicated by the following markers.
WARNING
Do not installation the product in
excessively hot areas, near open flames, in
areas prone to oily smoke, or where it could
come in contact with organic solvents.
Prohibited
Fire could result.
Do not let the remote controller get wet.
Short circuit or electric shock could result.
Do not expose
to water
Do not disassemble the product more than
necessary or modify it.
Fire, electric shock or injury could result.
Do not disassemble
Do not install the remote controller in a
bathroom or other highly humid location.
Electric shock or short circuit could result.
Do not install
in bathroom
CAUTION
Wear gloves during installation.
Injury could result.
Securely install parts so that there are no
twists and deformations.
Injury could result if the product falls.
Do not give impact by dropping/throwing
the product during installation.
Air/water leakage could result due to damage
inside the product structure.
Follow
Securely install parts.
instructions
Injury could result if the product falls.
Do not inspect, install or remove the
product and parts under unstable
conditions.
Injury could result from falling over.
This applies to mishandling or misoperation of the product which may lead to a fatal or
serious injury.
Use designated electric wires and connect them securely so they do
not come out.
Poor connections could result in fire.
Make sure to turn the unit power before installation.
During electrical work, make sure to turn off the circuit breaker.
Electric shock or injury could result.
Be sure to shut off the circuit breaker if the Lossnay will not be used
for a long period after installation.
Electric shock from deteriorated insulation or fire from a short circuit could
result.
Electrical work must be done by an electrical contractor (a licensed
electrician in accordance with the technical standards of the equipment
Follow
and internal wiring provisions to ensure safety.
instructions
Poor connection or improper electric work may result in electric shock and/
or fire.
This applies to mishandling or misoperation of the product, which will lead to an injury or
damage to your home, household effects, etc.
Select a sufficiently strong location and install the remoter controller securely.
Injury could result if the product falls.
Make sure to use accessory parts/designated parts for the installation parts.
Using parts other than our designated parts could result in malfunctions and
accidents.
This appliance is not intended for use by persons (including children) with
reduced physical sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Follow
Children should be supervised to ensure that they do not play with the
instructions
appliance. (This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.)
Applicable models
VL-250CZPVU-R-E / VL-250CZPVU-L-E
VL-350CZPVU-R-E / VL-350CZPVU-L-E
For use by dealers/contractors
2011876H53301

Advertisement

loading

Summary of Contents for Mitsubishi Electric P-RCC-E

  • Page 1 2011876H53301 LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT RC COVER Applicable models MODEL P-RCC-E VL-250CZPVU-R-E / VL-250CZPVU-L-E VL-350CZPVU-R-E / VL-350CZPVU-L-E Installation Manual For use by dealers/contractors ■ This product is for residential use. ■ This RC COVER is used to cover the space when the remote controller is removed from the Lossnay unit. Do not use this product for any other purpose.
  • Page 2 2. Outside dimensions Accessories Wood screw (4.1 X 16): 2 Roundhead cross slot screw (M4 X 30): 2 Cable with noise filter: 1 Terminal protective cap: 1 (Cable length outside the prod- uct: Approximately 820 mm) 18.4 63.2 Unit: mm 3.
  • Page 3 5. Installation method *The illustrations show VL-350CZPVU-R-E. Remove the front casing. Attach the RC COVER. 1) Remove the filter cover and the filter case towards your side 1) Remove the two screws from the base plate. (three locations). Base plate Filter case Screw 2)...
  • Page 4 5. Installation method (Continued) 4) Store the cable with noise filter along with the side face of the control box as shown and pass the cable through the code bush. 2-core wire must not Thread the sheath part be seen on the back. Note: of the cable to the front.