Download Print this page
Siemens SIMATIC RF300 System Manual
Hide thumbs Also See for SIMATIC RF300:

Advertisement

Quick Links

SIMATIC Ident
RFID systems
SIMATIC RF300
System Manual
02/2021
C79000-G8976-C345-09
Introduction
Safety information
System overview
Planning the RF300 system
Readers
Antennas
RF300 transponder
ISO transponder
System integration
System diagnostics
Appendix
Service & Support
1
2
3
4
5
6
7
8
9
10
A
B

Advertisement

loading

Summary of Contents for Siemens SIMATIC RF300

  • Page 1 Introduction Safety information System overview SIMATIC Ident Planning the RF300 system RFID systems SIMATIC RF300 Readers Antennas System Manual RF300 transponder ISO transponder System integration System diagnostics Appendix Service & Support 02/2021 C79000-G8976-C345-09...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3 Example of container and cardboard container handling: Use of ISO transponders ....36 Planning the RF300 system ......................... 39 Fundamentals of application planning................39 4.1.1 Selection criteria for SIMATIC RF300 components ............... 39 4.1.2 Transmission window and read/write distance ..............40 4.1.3 Width of the transmission window ..................
  • Page 4 Approvals ........................138 5.1.11 Dimension drawing......................140 SIMATIC RF310R with Scanmode ..................140 5.2.1 Features .......................... 141 5.2.2 Ordering data ........................141 5.2.3 Pin assignment of the RS-422 interface ................141 5.2.4 LED operating display....................... 142 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 5 5.5.3 Pin assignment of RF380R RS-232/RS-422 interface ............187 5.5.4 LED operating display....................... 188 5.5.5 Ensuring reliable data exchange ..................189 5.5.6 Metal-free area ........................ 189 5.5.7 Minimum distance between RF380R readers ..............190 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 6 Technical specifications ....................221 6.3.6 Dimension drawing......................222 ANT 8 ..........................222 6.4.1 Characteristics ......................... 222 6.4.2 Ordering data ........................222 6.4.3 Transmission window....................... 223 6.4.4 Flush-mounted in metal ....................224 6.4.5 Minimum clearances......................224 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 7 6.9.7 Technical data........................250 6.9.8 Dimension drawing......................251 6.10 ANT 30 (stainless steel variant) ..................252 6.10.1 Features .......................... 252 6.10.2 Ordering data ........................252 6.10.3 Antenna connection ......................253 6.10.4 Transmission window....................... 254 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 8 Mounting on metal ......................283 7.7.4 Mounting instructions...................... 285 7.7.5 Technical specifications ....................285 7.7.6 Dimensional drawing ....................... 286 SIMATIC RF380T....................... 287 7.8.1 Features .......................... 287 7.8.2 Ordering data ........................287 7.8.3 Installation guidelines for RF380T ..................287 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 9 Features .......................... 316 8.6.2 Ordering data ........................316 8.6.3 Mounting in metal ......................317 8.6.4 Technical specifications ....................318 8.6.5 Dimension drawing......................319 MDS D139 ........................320 8.7.1 Characteristics ......................... 320 8.7.2 Ordering data ........................320 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 10 Use in hazardous areas for gasses..................348 8.13.5.2 Use in hazardous areas for dusts ..................349 8.13.6 Technical specifications ....................349 8.13.7 Dimensional drawing ....................... 351 8.14 MDS D400 ........................352 8.14.1 Features .......................... 352 8.14.2 Ordering data ........................352 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 11 Characteristics ......................... 378 8.21.2 Ordering data ........................378 8.21.3 Application example ......................379 8.21.4 Technical specifications ....................379 8.21.5 Dimension drawing......................381 8.22 MDS D460 ........................381 8.22.1 Characteristics ......................... 381 8.22.2 Ordering data ........................382 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 12 Characteristics ......................... 406 8.29.2 Ordering data ........................406 8.29.3 Application example ......................407 8.29.4 Technical specifications ....................407 8.29.5 Dimension drawing......................409 8.30 MDS D560 ........................409 8.30.1 Characteristics ......................... 409 8.30.2 Ordering data ........................410 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 13 A.3.2 Reader RF3xxR (RS422) with ASM 475................459 A.3.3 Reader RF3xxR (RS-422) with RF120C................460 A.3.4 Reader RF380R (RS232) - PC..................... 460 Ordering data ........................462 Service & Support ..........................473 Index ..............................475 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 14 Table of contents SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 15 • Function manual "Ident profile and Ident blocks, standard function for Ident systems" • Function manual "FB 45 for MOBY U, MOBY D, RF200, RF300" You will find the latest versions of these manuals on the pages of the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14971/man).
  • Page 16 Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different country-specific regulations.
  • Page 17 Reader RF360R • ISO Transponder MDS D560 Abbreviations and naming conventions The following terms/abbreviations are used synonymously in this document: Transponder, tag Data carrier, mobile data storage, (MDS) Communications module (CM) Interface module (ASM) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 18 Introduction 1.1 Preface SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 19 Danger of burns Note that some outer components of the reader are made of metal. Depending on the environmental conditions temperatures can occur on the device that are higher than the maximum permitted operating temperature. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 20 • RF350R + ANT 12: ≥ 25 mm • RF350R + ANT 18: ≥ 50 mm • RF350R + ANT 30: ≥ 80 mm • RF360R: ≥ 160 mm • RF380R: ≥ 250 mm • RF382R: ≥ 130 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 21 Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://www.siemens.com/industrialsecurity.
  • Page 22 Safety information 2.1 Security information SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 23 System overview RFID systems RFID systems from Siemens control and optimize material flow. They identify reliably, quickly and economically, are insensitive to contamination and store data directly on the product or workpiece carrier. Table 3-1 Overview of SIMATIC RFID systems...
  • Page 24 3.2.1 System overview of SIMATIC RF300 SIMATIC RF300 is an inductive identification system specially designed for use in industrial production for the control and optimization of material flow. Thanks to its compact dimensions, RF300 is the obvious choice where installation conditions are restricted, especially for assembly lines, handling systems and workpiece carrier systems.
  • Page 25 System overview 3.2 SIMATIC RF300 • Improved 5-color LED display • Expanded functions for trained users: – Address information for the "INIT" command no longer necessary – Expanded "RESET" parameter – The MDS-STATUS "Mode 3" functions with all transponder types –...
  • Page 26 System overview 3.2 SIMATIC RF300 3.2.2 RFID components and their function System components overview Table 3-3 RF300 system components Component Description Communication mod‐ A communication module is used to integrate the RF identification system in controllers/automation systems. Reader The reader ensures inductive communication and power supply to the trans‐...
  • Page 27 System overview 3.2 SIMATIC RF300 RF300 system components for high-performance applications Figure 3-1 High performance system overview Table 3-4 Reader-transponder combination options for high-performance applications I Transponder RF310R RF340R RF360R RF380R RF320T ✓ ✓ ✓ ✓ RF330T ✓ ✓ ✓...
  • Page 28 System overview 3.2 SIMATIC RF300 Table 3-5 Reader-transponder combination options for high-performance applications II Transponder RF350R RF350R RF350R RF350R RF350R RF350R with ANT 1 with ANT 3 RF350R with ANT 8 with ANT 12 with ANT 18 with ANT 30...
  • Page 29 System overview 3.2 SIMATIC RF300 RF300 system components for medium-performance applications Figure 3-2 System overview medium-performance Table 3-6 Reader-transponder combination options for medium-performance applications I Transponder / RF310R RF340R RF360R RF380R (RS-422) MDS D100 ✓ ✓ ✓ ✓ MDS D117...
  • Page 30 System overview 3.2 SIMATIC RF300 Transponder / RF310R RF340R RF360R RF380R (RS-422) MDS D124 ✓ ✓ ✓ ✓ MDS D126 ✓ ✓ ✓ ✓ MDS D127 MDS D139 ✓ ✓ ✓ ✓ MDS D160 ✓ ✓ ✓ MDS D165 ✓...
  • Page 31 System overview 3.2 SIMATIC RF300 Transponder / RF350R RF350R RF350R RF350R RF350R RF350R with ANT 1 with ANT 3 RF350R with ANT 8 with ANT 12 with ANT 18 with ANT 30 with ANT 3S MDS D127 ✓ ✓ ✓...
  • Page 32 System overview 3.2 SIMATIC RF300 RF300 system components for Scanmode applications Figure 3-3 Scanmode system overview Table 3-8 Reader-transponder combination options for Scanmode applications Transponder / RF310R RF380R RF382R MDS D100 ✓ ✓ MDS D124 ✓ ✓ ✓ SIMATIC RF300...
  • Page 33 SIMATIC RF300 is primarily used for non-contact identification of containers, palettes and workpiece holders in a closed production circuit. The data carriers (transponders) remain in the production chain and are not supplied with the products. SIMATIC RF300, with its compact transponder and reader enclosure dimensions, is particularly suitable in confined spaces.
  • Page 34 • Ancillary assembly lines in the automotive industry, component suppliers • Small assembly lines Note Limitation of application Note that the SIMATIC RF300 system is not a product line for access control or other security- related authorization. Application examples • Production lines for engines, gearboxes, axles, etc.
  • Page 35 WIN-LC terminal located at each workstation. This means that virtually no additional data management is required on the control computer. The production order data can also be read for servicing purposes via the mobile SIMATIC RF350M reader. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 36 Advantages at a glance: • Decision points in the conveyor system can be installed in a more favorable way (mechanically) • Different sizes of containers with different depths can be identified due to the range SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 37 Again, one and the same reader hardware is used for this. The maximum transport speed is 0.8 m/s. In addition, flexible identification is possible at each location and at any time using the mobile SIMATIC RF350M reader. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 38 System overview 3.3 System configuration Figure 3-5 Example of container and cardboard container handling SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 39 Planning the RF300 system Fundamentals of application planning 4.1.1 Selection criteria for SIMATIC RF300 components Assess your application according to the following criteria, in order to choose the right SIMATIC RF300 components: • Transmission distance (read/write distance) • Tracking tolerances •...
  • Page 40 For the transponder to function correctly, a minimum field strength at the transponder must be achieved at a distance S from the reader or the antenna. The figures below show the transmission window between transponder and reader or between transponder and antenna: SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 41 Length of a transmission window in the y direction while maintaining the working distance (L ≠ L with RF380R and RF382R) Field centerpoint Intersection of the axes of symmetry of the transponder Figure 4-1 Transmission window and read/write distance reader SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 42 Diameter of a transmission window Intersection of the axes of symmetry of the transponder Figure 4-2 Transmission window and read/write distance round antenna SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 43 Length of the transmission window Tracking tolerance The width of the transmission window (W) is particularly important for the mechanical tracking tolerance. The formula for the dwell time is valid without restriction when W is observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 44 It is therefore advisable to select a distance > 30 % of S ① Main field ② Secondary field Figure 4-3 Gap in the field resulting from secondary fields SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 45 Secondary fields with shielding The following graphic shows typical primary and secondary fields, with metal shielding this time. The metal shielding prevents the reader from detecting tags via the secondary field. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 46 If no transponder is recognized for a longer period of time, the reader changes back to the "Search for transponders" status. When a "RESET" command is received, the reader changes back to the normal operation as known from the RF300. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 47 The figure below shows the active area for various directions of transponder motion: Transmission window Direction of motion of the transponder Detection area L x W Figure 4-6 Detection areas of the reader for different directions of transponder motion SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 48 The dwell time is the time in which the transponder remains within the transmission window of the reader. The reader can exchange data with the transponder during this time. The dwell time is calculated as follows: SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 49 82255083). Field data for transponders, readers and antennas The following tables show the field data for all SIMATIC RF300 components of transponders and readers. This makes the correct selection of a transponder and reader particularly easy. All technical data listed is typical data and is applicable for an ambient room temperature of between 0 and +50 °C, a supply voltage of between 22 V DC and 27 V DC as well as an...
  • Page 50 Operating distance (S Limit distance (S window (L) RF320T 1...23 RF330T 2...18 RF340T 2...36 RF350T 2...47 RF360T 2...60 RF370T 2...45 All values are in mm The values relate to the RF310R reader as of version "D". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 51 All values are in mm Table 4-6 Field data RF350R reader / ANT 18 Diameter of the transmis‐ Operating distance (S Limit distance (S sion window (L RF320T 1...10 RF330T 1...11 RF340T 1...18 All values are in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 52 This output power does not need to be manually set for RF380R readers of the 2nd generation (6GT2801-3BAx0) because the power limits are optimized automatically depending on the reader-transponder distance. For reasons of compatibility this setting can nevertheless be SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 53 MDS D424 1...68 MDS D425 1...22 MDS D426 5...75 MDS D428 1...40 MDS D460 1...32 MDS D524 1...70 MDS D525 1...22 MDS D526 5...80 MDS D528 1...43 MDS D560 1...32 All values are in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 54 Limit distance (S window (L) MDS D100 5...110 MDS D124 2...65 MDS D126 2...90 MDS D139 5...85 MDS D160 2...35 MDS D165 5...100 MDS D200 5...95 MDS D261 5...80 MDS D324 2...66 MDS D339 5...90 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 55 1...20 All values are in mm Table 4-14 Field data RF350R reader / ANT 3S Diameter of the transmis‐ Operating distance (S Limit distance (S sion window (L MDS D117 0...2 MDS D127 0...2 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 56 Diameter of the transmis‐ Operating distance (S Limit distance (S sion window (L MDS D117 0...5 MDS D124 2...24 MDS D127 0...5 MDS D160 1...18 MDS D324 1...22 MDS D421 0...4 MDS D422 1...10 MDS D424 1...27 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 57 All values are in mm Table 4-19 Field data RF360R reader Length of the transmission window Operating distance Limit distance (S in x direction (L in the y direction MDS D100 5...110 MDS D124 2...60 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 58 2...96 MDS D339 17...160 MDS D400 10...165 MDS D423 5...75 MDS D424 2...120 MDS D425 2...35 MDS D426 2...155 MDS D428 2…70 MDS D460 2…65 MDS D524 2...115 MDS D525 2...35 MDS D526 2...155 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 59 • A maximum median deviation of ±2 mm is possible in static mode (without affecting the field data). • In dynamic mode, make sure that rectangular transponders cross the antenna field in the longitudinal direction. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 60 The MDS E transponders are products that will be discontinued. These are relevant for migration projects in which existing RFID systems are replaced by SIMATIC RF300 of the 2nd generation. Note that the MDS E transponders can only be operated in conjunction with the readers of the...
  • Page 61 ≥ 40 ≥ 50 ≥ 80 ≥ 120 RF340T ≥ 60 ≥ 80 ≥ 100 ≥ 140 RF350T ≥ 60 ≥ 80 ≥ 100 ≥ 150 RF360T ≥ 60 ≥ 80 ≥ 100 ≥ 120 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 62 ≥ 180 ≥ 240 ≥ 360 ≥ 100, 180 MDS D425 ≥ 70 ≥ 100 ≥ 250 MDS D426 ≥ 120 ≥ 120 ≥ 280 ≥ 400 MDS D428 ≥ 100 ≥ 150 ≥ 300 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 63 ≥ 60 MDS D426 ≥ 140 ≥ 30 ≥ 60 MDS D428 ≥ 150 ≥ 60 ≥ 30 ≥ 50 ≥ 60 MDS D460 ≥ 150 ≥ 60 ≥ 30 ≥ 50 ≥ 60 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 64 Minimum distances antennas ANT 1 ANT 3 ANT 3S ANT 8 ANT 12 ANT 18 ANT 30 ≥ 300 ≥ 150 ≥ 20 ≥ 50 ≥ 70 ≥ 100 ≥ 100 All values are in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 65 • Metal-free area for flush-mounting of readers or their antennas and transponders in metal • Mounting of multiple readers or their antennas on metal frames or racks The following sections describe the impact on the operation of the RFID system when mounted in the vicinity of metal. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 66 This affects the entire field. In partic‐ Transponder ular, the transmission window be‐ tween reader and transponder is re‐ duced. Readers Metal Remedy: The transmission window is no lon‐ Transponder ger affected if the transponder is mounted differently. Reader SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 67 Note that antenna cables should not be coiled (cable coil = antenna) and should not be mounted directly on metal when coiled to avoid coupling. Antenna cables should be laid separately in a SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 68 Non-metallic spacer Insert a non-metallic spacer of 20 to 40 millimeter thick‐ ness between the reader and the iron frame. This will significantly reduce the induction of stray fields on the rack: Reader Reader SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 69 The range relates to use in a non-metallic environment. A value of 100% means no influence on the range. Note Possible reader-transponder combinations The tables of the following section show the possible reader-transponder combinations. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 70 Transponder flush-mounted in metal; minimum distance to the reader is 5 mm Transponder flush-mounted in metal; minimum distance to the reader is 10 mm Transponder flush-mounted in metal; minimum distance to the reader is 15 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 71 On metal; distance 20 mm Flush-mounted in metal; circumferential distance 20 mm MDS D261 Without metal On metal; distance 25 mm MDS D324 Without metal On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 72 Transponder flush-mounted in metal; minimum distance to the reader is 10 mm Transponder flush-mounted in metal; minimum distance to the reader is 15 mm Values of > 100 % can occur if transponders were developed specifically for mounting in/on metallic surroundings. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 73 Reduction of field data due to metal, range as %: Transponder and RF340R Transponder RF340R reader Without metal On metal Flush-mounted in metal (20 mm all- round) RF320T Without metal On metal; distance 20 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 74 Transponder flush-mounted in metal; minimum distance to the reader is 5 mm Transponder flush-mounted in metal; minimum distance to the reader is 10 mm Transponder flush-mounted in metal; minimum distance to the reader is 15 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 75 On metal; distance 20 mm Flush-mounted in metal; circumferential distance 20 mm MDS D261 Without metal On metal, distance 25 mm MDS D324 Without metal On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 76 Transponder flush-mounted in metal; minimum distance to the reader is 10 mm Transponder flush-mounted in metal; minimum distance to the reader is 15 mm Values of > 100 % can occur if transponders were developed specifically for mounting in/on metallic surroundings. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 77 Transponder ANT 1 ANT 1 ANT 1 flush- without metal on metal mounted in metal (40 mm all- round) RF320T Without metal On metal; distance 20 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 78 Transponder ANT 1 ANT 1 ANT 1 mounted without metal on metal in metal (40 mm all- round) MDS D100 Without metal On metal; distance 20 mm Flush-mounted in metal; circumferential distance 20 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 79 MDS D423 Without metal On metal; distance 0 mm Flush-mounted in metal; circumferential distance 0 mm MDS D424 Without metal MDS D524 On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 80 On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 81 MDS D124 Without metal On metal; distance 20 mm Flush-mounted in metal; circumferential distance 25 mm MDS D160 Without metal On metal; distance 0 mm Flush-mounted in metal; circum‐ ferential distance 10 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 82 Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. Values of > 100 % can occur if transponders were developed specifically for mounting in/on metallic surroundings. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 83 Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 8 Transponder ANT 8 without metal ANT 8 mounted in metal (0 mm all-round) MDS D117 Without metal On metal; distance 0 mm Flush-mounted in metal; circumferential distance 0 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 84 MDS D460 Without metal MDS D560 On metal; distance 10 mm Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 85 Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. Values of > 100 % can occur if transponders were developed specifically for mounting in/on metallic surroundings. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 86 MDS D460 Without metal MDS D560 On metal, distance 15 mm Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 87 Flush-mounted in metal; without surrounding clearance RF340T Without metal On metal; distance 30 mm Flush-mounted in metal; circumferential distance 20 mm RF350T Without metal Directly on metal Flush-mounted in metal; circumferential distance 20 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 88 0 mm MDS D423 Without metal On metal, distance 0 mm Flush-mounted in metal; circumferential distance 0 mm MDS D424 Without metal MDS D524 On metal 15 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 89 On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is adequate clearance to the metal. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 90 Flush-mounted in metal; circumferential distance 20 mm RF380T Without metal On metal; distance 0 mm Flush-mounted in metal; circumferential distance 40 mm Transponder flush-mounted in metal; minimum distance to the reader is 10 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 91 20 mm MDS D324 Without metal On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm MDS D339 Without metal On metal; distance 30 mm Flush-mounted in metal; circumferential distance 100 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 92 Without metal On metal Flush-mounted in metal (20 mm all- round) RF320T Without metal On metal; distance 20 mm Flush-mounted in metal; circumferential distance 20 mm RF330T Without metal on metal, distance 0 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 93 Transponder flush-mounted in metal; minimum distance to the reader is 15 mm Transponder flush-mounted in metal; minimum distance to the reader is 20 mm Transponder flush-mounted in metal; minimum distance to the reader is 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 94 On metal; distance 20 mm Flush-mounted in metal; circumferential distance 20 mm MDS D261 Without metal On metal, distance 25 mm MDS D324 Without metal On metal; distance 15 mm Flush-mounted in metal; circumferential distance 25 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 95 Transponder flush-mounted in metal; minimum distance to the reader is 20 mm Transponder flush-mounted in metal; minimum distance to the reader is 28 mm Transponder flush-mounted in metal; minimum distance to the reader is 32 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 96 Table 4-65 Reduction of field data by metal (in %): Transponder and RF382R Transponder Reader RF382R (ISO mode) Without metal On metal MDS D124 Without metal MDS D160 Without metal MDS D324 Without metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 97 "Polyamide 12". Fiber-optic cable Makrolon®2405 Decorative membrane Autotex V200 Socket Brass (copper alloy) CuZn40Pb2 Non-relevant component for resistance of complete housing In case of questions please contact Siemens Support (section "Service & Support (Page 473)"). SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 98 Glycerine 60 ℃ ++++ Isopropyl alcohol 20 ℃ ++++ 60 ℃ Potassium hydroxide, w. 60 ℃ ++++ Lysol 20 ℃ Magnesium salts, w. c. s. 60 ℃ ++++ Methyl alcohol, w. 60 ℃ ++++ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 99 4.5.2.1 Overview of the transponders and their housing materials The following sections describe the resistance to chemicals of the various transponders. Resistance to chemicals depends on the housing materials used to manufacture the transponders. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 100 MDS D428 Note Chemical substances not listed The following sections describe the resistance of the various transponders to specific substances. If you require information about chemical substances that are not listed, contact Customer Support. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 101 20 ℃ ○ Chlorine water (saturated solution) 20 ℃ Chromates (K–, Na– among others) Up to 50 % 40 ℃ ++++ Chromic acid Up to 30 % 20 ℃ ○ Chromosulfuric acid 20 ℃ ○ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 102 Nitrates (ammonium..., K– among oth‐ 60 ℃ ++++ ers) Nitroglycerin 20 ℃ ○ Oxalic acid 20 ℃ ++++ Phenol 20 ℃ ++++ Phosphates (ammonium..., Na– among 60 ℃ ++++ others) Phosphoric acid 60 ℃ ++++ 20 ℃ ++++ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 103 Test conditions Rating Concentration [%] Temperature [°C] Mineral lubricants ++++ Aliphatic hydrocarbons ++++ Aromatic hydrocarbons ++++ Gasoline ++++ Weak mineral acids Strong mineral acids ○ Weak organic acids Strong organic acids ○ Oxidizing acids ○ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 104 20 ℃ ++++ 60 ℃ Calcium chloride, w. 20 ℃ ++++ 60 ℃ Calcium nitrate, w. c. s. 20 ℃ ++++ c. s. 60 ℃ Chlorine 20 ℃ ○ Chrome baths, tech. 20 ℃ ○ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 105 60 ℃ ++++ Sulfuric acid 20 ℃ 20 ℃ Hydrogen sulfide 60 ℃ ++++ Carbon tetrachloride 60 ℃ ++++ Toluene 20 ℃ ++++ 60 ℃ Detergent high 60 ℃ ++++ Plasticizer 60 ℃ ++++ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 106 Weak alkaline solutions ○ Strong alkaline solutions ○ Trichloroethylene ○ Perchloroethylene ○ Acetone ○ Alcohols Hot water (hydrolysis resistance) ○ Explanation of the rating ++++ Resistant Practically resistant Conditionally resistant Less resistant Not resistant ○ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 107 23 ℃ ++++ Tested fuels 80 ℃ ++++ FAM testing fluid 80 ℃ acc. to DIN 51 604-A Toluene 1, 1, 1-Trichloroethane 80 ℃ ++++ Xylene Zinc chloride (saturated) 80 ℃ 75 ℃ ++++ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 108 Guidelines for electromagnetic compatibility (EMC) 4.6.1 Overview These EMC directives answer the following questions: • Why are EMC directives necessary? • What types of external interference have an impact on the system? • How can interference be prevented? SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 109 Since the RFID modules are merely components of an overall system, and sources of interference can arise as a result of combining different components, certain directives have to be followed when setting up a plant. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 110 • Aluminium parts are not suitable for ground connections. Plan the cable installation • Break the cabling down into cable groups and install these separately. • Always route power cables, signal cables and HF cables through separated ducts or in separate bundles. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 111 If one of the components is missing, e.g. the coupling path between the interference source and the interference sink, the interference sink is unaffected, even if the interference source is transmitting a high level of noise. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 112 Transmitter Antenna Electromagnetic field (e.g. professional mobile ra‐ dio) Ground or reference potential Voltage difference Transient currents difference Power cables Current flow Electrical and magnetic field, system disturbance High-voltage cable Voltage difference Electrical field SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 113 Position the antennas further apart. tennas • Erect suitable damping materials between the antennas. • Reduce the power of the readers. Please follow the instructions in the sec‐ tion Installation guidelines/reducing the effects of metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 114 Inappropriate physical arrangement of cables Control cabinet or housing • Missing or incorrectly wired equalizing conductor • Missing or incorrect earthing • Inappropriate physical arrangement • Components not mounted securely • Unfavorable cabinet configuration SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 115 (unpainted). When setting up the control cabinet, interference can be prevented easily by observing certain guidelines. Power components (transformers, drive units, load power supply units) should be arranged separately from the control components (relay control unit, SIMATIC S7). SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 116 • The load connections and power cables should be installed separately from the signal cables with a minimum clearance of 10 cm. Power supply CC/EU Shield plate Drive Figure 4-12 Prevention of interference by optimum configuration SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 117 230 V coils when the coil is switched. The use of freewheeling diodes or RC circuits prevents interference voltages and thus stray interference on conductors installed parallel to the coil conductor. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 118 The diagram below shows that the formation and level of electrostatic charge depends on the materials and the ambient conditions (relative humidity). A combination of synthetic fibers and dry atmosphere particularly promotes charging. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 119 30 V. These invisible forms of electrostatic discharge can cause total failure or less noticeable damage, potentially affecting the long-term reliability and performance of electronic equipment. For some devices, the damage may go unnoticed for much of their operating life. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 120 The friction between the pallet and the rollers generates electrostatic charges. The higher the friction, the faster the electrostatic charge increases. High frictional forces act to increase the ② electrostatic charge especially when the pallet stops SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 121 Installation example with ESD brushes Targeted and controlled discharge occurs over Via ESD brushes, so that high electrostatic charges and associated uncontrolled electrostatic discharges do not happen in the first place. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 122 • When connecting the equipotential bonding conductors to the centralized equipotential bonding strip (EBS), the power components and non-power components must be combined. • The equipotential bonding conductors of the separate modules must lead directly to the equipotential bonding strip. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 123 • For digital signals, the shield has to be connected to the enclosure at both ends • Since interference signals are frequently within the HF range (> 10 kHz), a large-area HF- proof shield contact is necessary SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 124 The shielding bus must be connected to the PE busbar. If shielded cables have to be interrupted, the shield must be continued via the corresponding connector housing. Only suitable connectors may be used for this purpose. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 125 Interruption of shielded cables If intermediate connectors, which do not have a suitable shield connection are used, the shield must be continued by fixing cable clamps at the point of interruption. This ensures a large-area, HF-conducting contact. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 126 Planning the RF300 system 4.6 Guidelines for electromagnetic compatibility (EMC) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 127 • Function manual "Ident profile and Ident blocks (https:// support.industry.siemens.com/cs/ww/en/view/106368029)", • Product Information "Input parameters for the RF300 system for programming via communications modules (https://support.industry.siemens.com/cs/ww/en/ps/15033/ man)", • Function manual "FB 45 (https://support.industry.siemens.com/cs/ww/en/view/21738808)" as of version "AS ≥ A3". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 128 Special ISO 14443 commands such as "INCREMENT", "DECREMENT" or "SET-VALUE" are not supported. SIMATIC RF310R 5.1.1 Features SIMATIC RF310R Characteristics ① Design RS-422 interface ② LED operating display Area of application Identification tasks on small assembly lines in harsh industrial environments SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 129 The reader is in the "Setup" mode, in the status "Show quality", has not yet received a "RESET" command and is not ready. Depending on the signal strength, the LED flickers or is lit permanently. The reader has received a "RESET" command. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 130 The RF310R can be flush-mounted in metal. Allow for a possible reduction in the field data. To avoid any influence on the field data, the distance "a" should be kept to. a ≥ 20 mm Figure 5-1 Metal-free area for RF310R SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 131 Figure 5-3 Face-of-face distance between two RF310Rs 5.1.8 Using the reader in hazardous area WARNING Risk of explosion In a flammable or combustible environment, no cables may be connected to or disconnected from the device. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 132 -25 °C < Ta < +70 °C IP64 = 24 V DC, 60 mA The equipment also has the following additional information: XXXYYYZZZ [= serial number, is assigned during production] DEMKO 17 ATEX 1767 X [= certificate number] SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 133 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas Part 7: Equipment protection by increased safety "e" CSA C22.2 NO. 60079-7 UL 60079-31 Hazardous areas Part 31: Equipment dust ignition protection by enclosure "t" CSA C22.2 NO. 60079-31 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 134 When using the reader, check to make sure that the temperature class is adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the reader can lead to ignitions of gas-air mixtures. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 135 • After removing the connections (antenna cable, signal/supply cable), the connectors must be checked for contamination and, if necessary, cleaned before being inserted again. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 136 The device must be set up and installed so that it is mechanically protected. After disconnecting connections (signal/supply cable), before the connectors are plugged in again, the connectors must be checked for contamination and, if necessary, cleaned. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 137 Supply voltage, current consumption, power loss Supply voltage 24 VDC Typical current consumption 60 mA Permitted ambient conditions Ambient temperature • During operation • -25 … +70 °C • During transportation and storage • -40 … +85 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 138 5.1.10 Approvals FCC information Siemens SIMATIC RF310R (MLFB 6GT2801-1BA10); FCC ID NXW-RF310R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 139 NOTE 1: These levels of transient overvoltage are typical for equipment supplied from the building wiring. • f) using a "NEC Class 2" power supply is required • g) the device is categorized as pollution degree 3/4 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 140 5.2 SIMATIC RF310R with Scanmode 5.1.11 Dimension drawing Figure 5-4 Dimension drawing for RF310R Dimensions in mm SIMATIC RF310R with Scanmode You will find detailed information on the SIMATIC RF310R with Scanmode on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109762012). SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 141 RF310R Scanmode with RS422 interface 6GT2801-1BA20-0AX1 5.2.3 Pin assignment of the RS-422 interface Table 5-6 Pin assignment Assignment Device end 8-pin M12 + 24 V - Transmit + Transmit + Receive - Receive Unassigned Earth (shield) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 142 The RF310R Scanmode can be flush-mounted in metal. Allow for a possible reduction in the field data. Figure 5-5 Metal-free area for RF310R Scanmode To avoid any impact on the field data, the distance a should be ≥ 20 mm. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 143 ≥ 300 mm Figure 5-7 Face-to-face distance between two RF310R Scanmode readers 5.2.8 Technical specifications Table 5-8 Technical specifications of the RF310R reader with Scanmode 6GT2801-1BA20-0AX1 Product type designation SIMATIC RF310R Scanmode Radio frequencies SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 144 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (L x W x H) 79.6 x 55 x 30 mm Weight 170 g Type of mounting 4 x M5 screws; 1.5 Nm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 145 5.2.9 Approvals FCC information Siemens SIMATIC RF310R (MLFB 6GT2801-1BA20-0AX1); FCC ID NXW-RF310R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 146 (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement. 5.2.10 Dimension drawing Figure 5-8 Dimension drawing RF310R Scanmode Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 147 Identification tasks on assembly lines in harsh industrial environments 5.3.1.2 Ordering data Table 5-9 Ordering data for RF340R Article number RF340R with RS-422 interface (3964R) 6GT2801-2BA10 RF340R with RS422 interface (3964R) 6GT2801-2BA10-0AX2 and ATEX, IECEx, UL HAZ. LOC approval SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 148 Operating mode "without presence": Transponder present and command cur‐ rently being executed There is an error. The number of flashes provides information about the current error. You will find more information on error messages in the section "System diagnostics (Page 425)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 149 The RF340R can be flush-mounted in metal. Allow for a possible reduction in the field data. To avoid any influence on the field data, the distance "a" should be kept to. a ≥ 20 mm Figure 5-9 Metal-free area for RF340R SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 150 Face-of-face distance between two RF340Rs 5.3.1.8 Using the readers in a hazardous area WARNING Risk of explosion In a flammable or combustible environment, no cables may be connected to or disconnected from the device. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 151 -25 °C < Ta < +70 °C IP64 = 24 V DC, 60 mA The equipment also has the following additional information: XXXYYYZZZ [= serial number, is assigned during production] DEMKO 17 ATEX 1767 X [= certificate number] SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 152 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas Part 7: Equipment protection by increased safety "e" CSA C22.2 NO. 60079-7 UL 60079-31 Hazardous areas Part 31: Equipment dust ignition protection by enclosure "t" CSA C22.2 NO. 60079-31 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 153 When using the reader, check to make sure that the temperature class is adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the reader can lead to ignitions of gas-air mixtures. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 154 • After removing the connections (antenna cable, signal/supply cable), the connectors must be checked for contamination and, if necessary, cleaned before being inserted again. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 155 The device must be set up and installed so that it is mechanically protected. After disconnecting connections (signal/supply cable), before the connectors are plugged in again, the connectors must be checked for contamination and, if necessary, cleaned. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 156 Supply voltage, current consumption, power loss Supply voltage 24 VDC Typical current consumption 60 mA Permitted ambient conditions Ambient temperature • During operation • -25 … +70 °C • During transportation and storage • -40 … +85 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 157 5.3.1.10 Approvals FCC information Siemens SIMATIC RF340R (MLFB 6GT2801-2BA10); FCC ID NXW-RF340R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 158 NOTE 1: These levels of transient overvoltage are typical for equipment supplied from the building wiring. • f) using a "NEC Class 2" power supply is required • g) the device is categorized as pollution degree 3/4 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 159 Readers 5.3 SIMATIC RF340R/RF350R 5.3.1.11 Dimension drawing Figure 5-12 Dimension drawing for RF340R Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 160 ANT 1, ANT 3, ANT 12, ANT 18 or ANT 30. 5.3.2.2 Ordering data Table 5-13 Ordering data for RF350R Article number RF350R with RS-422 interface (3964R) 6GT2801-4BA10 RF350R with RS422 interface (3964R) 6GT2801-4BA10-0AX2 and ATEX, IECEx, UL HAZ. LOC approval SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 161 Operating mode "without presence": Transponder present and command cur‐ rently being executed There is an error. The number of flashes provides information about the current error. You will find more information on error messages in the section "System diagnostics (Page 425)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 162 You will find the current versions of the standards in the currently valid ATEX certificates. ATEX mark NOTICE Validity only when the devices are marked There is a corresponding approval only with devices to which the Ex mark is applied. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 163 You will find the current versions of the standards in the currently valid IECEx certificates. IECEx mark NOTICE Validity only when the devices are marked There is a corresponding approval only with devices to which the IECEx mark is applied. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 164 You will find the current versions of the standards in the currently valid UL HAZ. LOC. certificates UL HAZ. LOC. mark NOTICE Validity only when the devices are marked There is a corresponding approval only with devices to which the UL HAZ. LOC. mark is applied. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 165 When using the reader, check to make sure that the temperature class is adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the reader can lead to ignitions of gas-air mixtures. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 166 The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are higher than 80 °C (smoldering temperature). Ambient temperature range Temperature value -25 °C < Ta < +70 °C T80 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 167 Antenna values Ui, Ii, Pi, Ci, Li for installation in hazardous areas Note Read the document "A5E44647714" Read the information in the document "Control Drawing A5E44647714" shipped with the reader for installation of the reader RF350R - 2nd generation in a hazardous area. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 168 0.105 0.55 38.2 0.096 6GT2398-1CA00 With integrated 34.5 0.105 0.55 0.86 cable 3 m ANT 30 6GT2398-1CD10-0AX0 without cable 34.5 0.105 0.55 43.2 0.108 6GT2398-1CD00 With integrated 34.5 0.105 0.55 0.835 cable 3 m SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 169 Note Read the document "A5E44647714" Read the information in the document "Control Drawing A5E44647714" shipped with the reader for installation of the reader RF350R - 2nd Generation in a hazardous area. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 170 OR Zone 2, Group IIB, OR Zone 22, Group IIIC in HAZARDOUS LOCATIONS, OR non-hazardous locations only. WARNING WARNING EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 171 • ≤ 8000 • ≤ 1700 • ≤ 800 bytes/s bytes/s bytes/s Transmission speed 19.2, 57.6, 115.2 kBd Read/write distances of the reader See section "Field data for transponders, readers and antennas (Page 49)" SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 172 LED display design 2 LEDs, 5 colors Standards, specifications, approvals Proof of suitability Radio according to R&TTE directives EN 300330, EN 301489, CE, FCC, UL/CSA (IEC 61010), Ex approval (only 6GT2801-4BA10-0AX2) MTBF 260 years SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 173 5.3.2.9 Approvals FCC information Siemens SIMATIC RF350R (MLFB 6GT2801-4BA10); FCC ID NXW-RF350R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 174 • f) using a "NEC Class 2" power supply is required • g) the device is categorized as pollution degree 3/4 5.3.2.10 Dimension drawing Figure 5-13 RF350R dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 175 You can loop the PROFINET IO via the M12 round socket Note Configuration Manual SIMATIC RF360R You can find a detailed description of commissioning and configuration of the reader in the "SIMATIC RF360R (https://support.industry.siemens.com/cs/ww/en/ps/26319/man)" configuration manual. 5.4.2 Ordering data Table 5-18...
  • Page 176 When attaching the grounding cable, ensure it is not on a coated surface. Ensure that the ground cable is routed as short as possible and routed vertically downwards, and that is does not contain any conductor loops. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 177 If you want to make the cable yourself, ensure that the conductor cross-section matches the system setup or the corresponding protection (1.5 mm When using cables that are not preassembled, you need the tool for the specific cable/connector, for example, an insulation stripper, screwdriver or Allen wrench. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 178 Using only one PROFINET interface If only one PROFINET interface is required, it is essential to use the outer socket "X1 P2R" for reasons of interference immunity. Close the unused socket "X1 P1R" with a sealing cap. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 179 The reader is turned on and is searching for transponders. The reader is in the "Setup" mode, in the "Search for transponders" status and has not yet received a "RESET" command and is not ready. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 180 The flash test is performed for reader identification. At the same time, the LEDs of the reader and PROFINET/Ethernet LED display also flash. • The firmware is defective. There is an error. You can find more information on error messages in the section "System diagnostics (Page 425)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 181 The RF360R can be flush-mounted in metal. Allow for a possible reduction in the field data. To avoid any influence on the field data, the distance "a" should be kept to. a ≥ 20 mm Figure 5-15 Metal-free area for RF360R SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 182 Minimum distance between several RF360R readers RF360R side-by-side D ≥ ≥ 380 mm (with 2 readers) ≥ 500 mm (with more than 2 readers) Figure 5-16 Minimum distance between several RF360R readers RF360R face-to-face D ≥ 500 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 183 Transmission speed 100 Mbps Connector 2x M12 interface, 4-pin, D-coded Max. cable length 100 m Cable type STP Cat 5 Autonegotation Autocrossing Switch function Yes, internal PROFINET RT Vendor ID 0x002A Device ID 0x0C09 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 184 EN 301489, CE, FCC, UL/CSA (IEC 61010) MTBF 65 years The output power of the readers at the antenna (antenna input) does not correspond to the transmit power or radiated power of the device. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 185 5.4 SIMATIC RF360R 5.4.11 Approvals FCC information Siemens SIMATIC RF360R (MLFB 6GT2801-5BA30); FCC ID NXW-RF360R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 186 • f) using a "NEC Class 2" power supply is required • g) the device is categorized as pollution degree 3/4 5.4.12 Dimension drawing Figure 5-18 Dimension drawing RF360R Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 187 Pin assignment of RF380R RS-232/RS-422 interface You can connect the RF380R reader to a higher-level system via the internal RS-422 interface or via the RS-232 interface. After connection, the interface module automatically detects which interface has been used. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 188 Operating mode "without presence": Transponder present and command cur‐ rently being executed There is an error. The number of flashes provides information about the current error. You will find more information on error messages in the section "System diagnostics (Page 425)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 189 Metal-free area for RF380R The RF380R can be flush-mounted in metal. Allow for a possible reduction in the field data. To avoid any impact on the field data, the distance a should be ≥ 20 mm. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 190 Figure 5-21 Face-to-face distance between two RF380R 5.5.8 Using the reader in hazardous area WARNING Risk of explosion In a flammable or combustible environment, no cables may be connected to or disconnected from the device. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 191 -25 °C < Ta < +70 °C IP64 = 24 V DC, 130 mA The equipment also has the following additional information: XXXYYYZZZ [= serial number, is assigned during production] DEMKO 17 ATEX 1767 X [= certificate number] SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 192 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas Part 7: Equipment protection by increased safety "e" CSA C22.2 NO. 60079-7 UL 60079-31 Hazardous areas Part 31: Equipment dust ignition protection by enclosure "t" CSA C22.2 NO. 60079-31 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 193 When using the reader, check to make sure that the temperature class is adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the reader can lead to ignitions of gas-air mixtures. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 194 • After removing the connections (antenna cable, signal/supply cable), the connectors must be checked for contamination and, if necessary, cleaned before being inserted again. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 195 The device must be set up and installed so that it is mechanically protected. After disconnecting connections (signal/supply cable), before the connectors are plugged in again, the connectors must be checked for contamination and, if necessary, cleaned. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 196 Supply voltage, current consumption, power loss Supply voltage 24 VDC Typical current consumption 130 mA Permitted ambient conditions Ambient temperature • During operation • -25 … +70 °C • During transportation and storage • -40 … +85 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 197 5.5.10 Approvals FCC information Siemens SIMATIC RF380R (MLFB 6GT2801-3BA10); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 198 L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 199 5.6 SIMATIC RF382R with Scanmode - 1st generation 5.5.11 Dimension drawing Figure 5-22 Dimension drawing RF380R Dimensions in mm SIMATIC RF382R with Scanmode - 1st generation You will find detailed information on the SIMATIC RF382R with Scanmode on the Internet (https://support.industry.siemens.com/cs/ww/en/ps/15038/man). SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 200 You can connect the RF382R Scanmode reader via the internal RS-232/RS-422 interface or via a higher-level system. (See section "Basic rules (Page 110)") Make sure that the pin assignment is correct. In the factory settings, the reader is set to RS-232. Siemens can change the interface to RS-422.
  • Page 201 Mounting on metal The RF382R can be mounted directly on metal. Flush mounting on metal is not permitted. 5.6.7 Minimum distance between several RF382R Scanmode readers Figure 5-23 Minimum distance between several RF382R Scanmode readers SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 202 Figure 5-25 Line of maximum magnetic field strength The area of the maximum field strength and, therefore, the maximum range is identified by a laser icon: Figure 5-26 Laser labeling SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 203 The operating range between Levels includes secondary fields. The recommended operating range therefore lies in the green main field between Level 2 and Level 3. Limit distance (S ③ The limit distance lies on Level SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 204 Direction of motion of the transponder 5.6.9 Technical specifications Table 5-31 Technical specifications of the RF382R reader with Scanmode 6GT2801-3AB20-0AX0 Product type designation SIMATIC RF382R Scanmode Radio frequencies Operating frequency, rated value 13.56 MHz Electrical data SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 205 160 x 80 x 41 mm Weight 550 g Type of mounting 4 x M5 screws; 1.5 Nm Cable length for RS-422 interface, maximum RS-422 RS-232 1000 m 30 m LED display design 3-color LED SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 206 115 years 5.6.10 Approvals FCC information Siemens SIMATIC RF382R (MLFB 6GT2801-3AB20-0AX0); FCC ID NXW-RF382R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 207 Underwriters Laboratories (UL) acc. to standard UL 60950, Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E) or acc. to UL508 and C22.2 No. 142 (IND.CONT.EQ) 5.6.11 Dimensional diagram Figure 5-29 Dimension drawing SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 208 Readers 5.6 SIMATIC RF382R with Scanmode - 1st generation SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 209 3 m (integrated antenna cable) Connectable readers RF350R and RF350M: Degree of protection IP67 6.1.2 Ordering data Table 6-1 Ordering data ANT 1 Antenna Article number ANT 1 6GT2398-1CB00 (including one integrated antenna cable 3 m) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 210 If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 211 Antennas 6.1 ANT 1 Minimum distances from antenna to antenna ≥ 300 mm Figure 6-2 Minimum distance ANT 1 ≥ 500 mm Figure 6-3 Face-to-face minimum distance between two ANT 1 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 212 Type of mounting 2 x M5 screws Cable length 3 m (plug-in antenna cable) Standards, specifications, approvals MTBF 13698 years Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 213 ANT 3 Characteristics Area of application Small assembly lines Read/write distance up to 50 mm (depending on the transponder) Connecting cable 3 m (plug-in antenna cable) Connectable readers RF350R and RF350M: Degree of protection IP67 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 214 At a value lower than a, the field data changes significantly, resulting in a reduction in the limit distance and operating distance. Therefore, maintain the minimum distance a on/flush with the metal during installation. ① ANT 3 ② Metal Figure 6-5 ANT 3 mounted on metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 215 In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 150 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 216 -40 ... +85 °C Degree of protection according to EN 60529 IP67 Shock-resistant according to EN 60721-3-7 Class 7 500 m/s Vibration-resistant according to EN 60721-3-7 200 m/s Class 7 M2 Design, dimensions and weight SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 217 Standards, specifications, approvals MTBF 13698 years Warning: The values for shock and vibration are maximum values and must not be applied continuously. 6.2.6 Dimension drawing Figure 6-9 Dimension drawing ANT 3 (all values in mm) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 218 ANT 3S 6GT2398-1CD50-0AX0 (without antenna connecting cable) ANT 3S 6GT2398-1CD60-0AX0 (incl. one plug-in antenna connecting cable 3 m) Table 6-5 Ordering data ANT 3S accessories Accessories Article number Antenna connecting cable 6GT2391-0AH30 drag-capable, 3 m SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 219 Therefore, maintain the minimum distance a on/flush with the metal during installation. ① ANT 3S ② Metal Figure 6-10 ANT 3S mounted on metal ① ANT 3S ② Metal = 10 mm Figure 6-11 ANT 3S flush-mounted in metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 220 For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 20 mm Figure 6-12 Minimum distance ANT 3S ≥ 50 mm Figure 6-13 Face-to-face minimum distance between two ANT 3S SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 221 Type of mounting 2 x M4 screws Cable length 3 m (plug-in antenna cable) Standards, specifications, approvals MTBF 13698 years Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 222 RF350R and RF350M: Degree of protection IP67 6.4.2 Ordering data Table 6-6 Ordering data ANT 8 Antenna Article number ANT 8 6GT2398-1CF00 (without antenna cable) ANT 8 6GT2398-1CF10 (including one plug-in antenna cable 3 m) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 223 Operating distance between antenna and transponder Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-15 Transmission window ANT 8 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 224 In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 50 mm Figure 6-17 Minimum distance for ANT 8 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 225 Plug connection M8, 4-pin, pins on antenna side Mechanical specifications Enclosure • Material • Stainless steel V2A • Color • silver Permitted ambient conditions Ambient temperature • During operation • -25 ... +70 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 226 ② The cable must be secured in front of/behind the support sleeve so that no bending strain can be transferred to the antenna connector. Figure 6-19 Dimension drawing ANT 8 (all values in mm) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 227 Ordering data ANT 12 Antenna Article number ANT 12 6GT2398-1CC10 (incl. one integrated antenna connecting cable 0.6 m) ANT 12 6GT2398-1CC00 (incl. one integrated, antenna connecting cable suitable for cable carri‐ ers 3 m) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 228 Figure 6-20 Transmission window ANT 12 6.5.4 Flush-mounted in metal The antenna ANT 12 can be flush-mounted in metal. Allow for a possible reduction in the field data. Figure 6-21 ANT 12 flush-mounted in metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 229 For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 70 mm Figure 6-22 Minimum distance for ANT 12 ≥ 100 mm Figure 6-23 Face-to-face minimum distance between two ANT 12 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 230 145 g Type of mounting 2x plastic nuts M12 x 1 Cable length 3 m or 0.6 m Warning: The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 231 6.6.2 Ordering data Table 6-9 Ordering data ANT 18 Antenna Article number ANT 18 6GT2398-1CA10 (incl. one integrated antenna connecting cable 0.6 m) ANT 18 6GT2398-1CA00 (including one integrated antenna connecting cable 3 m) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 232 At values lower than a and b, the field data changes significantly, resulting in a reduction in the limit distance and operating distance. Therefore, during installation, maintain the minimum distances (a and b) on/flush with the metal. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 233 In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 100 mm Figure 6-27 Minimum distance for ANT 18 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 234 Pale turquoise Permitted ambient conditions Ambient temperature • During operation • -25 ... +70 °C • During transportation and storage • -40 ... +85 °C Degree of protection according to EN 60529 IP67 (front) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 235 ANT 30 Characteristics Area of application Small assembly lines Read/write distance up to 55 mm (depending on the transponder) Connecting cable Connectable readers RF350R and RF350M: Degree of protection IP67 (front) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 236 Operating distance between antenna and transponder Limit distance (maximum clear distance between upper surface of the reader and the antenna, at which the transmission can still function under normal conditions) Figure 6-30 Transmission window ANT 30 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 237 If the distance values specified in the tables are undershot, it is possible that the inductive fields will be affected. In this case, the data transmission time can increase unpredictably or a command is aborted with an error. For this reason, please observe the values in the tables. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 238 Minimum distance for ANT 30 ≥ 200 mm Figure 6-33 Face-to-face minimum distance between two ANT 30 6.7.6 Technical specifications 6GT2398-1CD00 Product type designation ANT 30 Electrical data Maximum write/read distance ANT ↔ transponder 55 mm Interfaces SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 239 2x plastic nuts M30 x 1.5 Cable length Warning: The values for shock and vibration are maximum values and must not be applied continuously. 6.7.7 Dimension drawing Figure 6-34 Dimension drawing ANT 30 (all values in mm) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 240 (including one plug-in antenna cable 3 m) Table 6-12 Ordering data ANT 12 accessories Accessories Article number Antenna connecting cable 6GT2391-0AH30 drag-capable, 3 m 6.8.3 Antenna connection Pins 1 and 3 Pins 2 and 4 Signal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 241 6.8 ANT 12 (stainless steel variant) CAUTION Minimum requirements for the antenna connecting cable We recommend that you use the antenna connecting cable "6GT2391-0AH30" from Siemens. Pay attention to the following minimum requirements if you want to configure an antenna cable yourself: •...
  • Page 242 Figure 6-35 Transmission window ANT 12 (stainless steel variant) 6.8.5 Flush-mounted in metal = 10 mm = 10 mm Figure 6-36 ANT 12 (stainless steel variant) flush-mounted in metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 243 For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 70 mm Figure 6-37 Minimum distance ANT 12 (stainless steel variant) ≥ 100 mm Figure 6-38 Face-to-face minimum distance between two ANT 12 (stainless steel variant) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 244 12 x 40 mm Thread (∅ x thread x L) M12 x 1 x 30 mm Weight without cable/with cable 15 g / 180 g Type of mounting 2x stainless steel nuts M12 x 1 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 245 The cable must be secured in front of/behind the support sleeve so that no bending strain can be transferred to the antenna connector. Figure 6-39 Dimension drawing ANT 12 (stainless steel variant) All dimensions in mm. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 246 Article number ANT 18 6GT2398-1DA00 (without antenna cable) ANT 18 6GT2398-1DA10 (including one plug-in antenna cable 3 m) Table 6-14 Ordering data ANT 18 accessories Accessories Article number Antenna connecting cable 6GT2391-0AH30 drag-capable, 3 m SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 247 Signal CAUTION Minimum requirements for the antenna connecting cable We recommend that you use the antenna connecting cable "6GT2391-0AH30" from Siemens. Pay attention to the following minimum requirements if you want to configure an antenna cable yourself: • Temperature: 80 ℃...
  • Page 248 Figure 6-40 Transmission window ANT 18 (stainless steel variant) 6.9.5 Flush-mounted in metal = 10 mm = 10 mm Figure 6-41 ANT 18 (stainless steel variant) flush-mounted in metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 249 For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 100 mm Figure 6-42 Minimum distance ANT 18 (stainless steel variant) ≥ 100 mm Figure 6-43 Face-to-face minimum distance between two ANT 18 (stainless steel variant) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 250 18 x 40 mm Thread (∅ x thread x L) M18 x 1 x 30 mm Weight without cable/with cable 40 g / 205 g Type of mounting 2x stainless steel nuts M18 x 1 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 251 The cable must be secured in front of/behind the support sleeve so that no bending strain can be transferred to the antenna connector. Figure 6-44 Dimension drawing ANT 18 (stainless steel variant) All dimensions in mm. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 252 Article number ANT 30 6GT2398-1DD00 (without antenna cable) ANT 30 6GT2398-1DD10 (including one plug-in antenna cable 3 m) Table 6-16 Ordering data ANT 30 accessories Accessories Article number Antenna connecting cable 6GT2391-0AH30 drag-capable, 3 m SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 253 Signal CAUTION Minimum requirements for the antenna connecting cable We recommend that you use the antenna connecting cable "6GT2391-0AH30" from Siemens. Pay attention to the following minimum requirements if you want to configure an antenna cable yourself: • Temperature: 80 ℃...
  • Page 254 Figure 6-45 Transmission window ANT 30 (stainless steel variant) 6.10.5 Flush-mounted in metal = 20 mm = 20 mm Figure 6-46 ANT 30 (stainless steel variant) flush-mounted in metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 255 For this reason, please observe the values in the tables. Minimum distances from antenna to antenna ≥ 100 mm Figure 6-47 Minimum distance ANT 30 (stainless steel variant) ≥ 200 mm Figure 6-48 Face-to-face minimum distance between two ANT 30 (stainless steel variant) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 256 30 x 40 mm Thread (∅ x thread x L) M30 x 1.5 x 30 mm Weight without cable/with cable 95 g / 260 g Type of mounting 2x stainless steel nuts M30 x 1.5 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 257 Class 2 of NEC or LPS of UL/IEC 60950”. Warning: The values for shock and vibration are maximum values and must not be applied continuously. 6.10.8 Dimension drawing Figure 6-49 Dimension drawing ANT 30 (stainless steel variant) All dimensions in mm. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 258 Antennas 6.10 ANT 30 (stainless steel variant) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 259 8 to 64 KB of FRAM memory, which has an almost unlimited capacity for reading and writing. Memory configuration of the RF300 transponders Physically identical memory When the OTP area is used, the corresponding user area (FF00-FF13) can no longer be modified (read only). SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 260 • 2 blocks (consecutive), Block 0 (FF80, length =4), Block 1 (FF84, length = 4): valid • 2 blocks (consecutive), Block 0 (FF80, length =4), Block 2 (FF88, length = 4): Invalid • 1 Block, Block 4 (FF90, length = 4): Invalid SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 261 (Page 50)" Mounting on metal Yes, with spacer Degree of protection IP67/IPx9K 7.2.2 Ordering data Table 7-1 Ordering data RF320T Article number RF320T 6GT2800-1CA00 Table 7-2 Ordering data for RF320T accessories Article number Spacer 6GT2690-0AK00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 262 If the distances (a and h) are not observed, a reduction of the field data results. It is possible to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible impact on the range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 263 Shock-resistant according to EN 60721-3-7 Class 7 1000 m/s Vibration-resistant according to EN 60721-3-7 200 m/s Class 7 M3 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 27 x 4 mm Weight SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 264 Memory size 32 KB EEPROM user memory Write/read range See section "Field data of RF300 transponders (Page 50)" Mounting on metal Yes flush mounted on/in metal Degree of protection IP68/IPx9K SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 265 Fixing hood RF330T / MDS D423 6GT2690-0AE00 7.3.3 Mounting on/in metal Direct mounting of the RF330T on metal is permitted. Mounting of the RF330T on metal Figure 7-5 Mounting of the RF330T on metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 266 Mounting of the RF330T in metal without clearance Note Reduction of the write/read range Note that when the device is flush-mounted in metal without a surrounding clearance ≥ 10 mm, the write/read range is significantly reduced. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 267 20 mbar • high pressure resistant (see degree of protec‐ tion IPx9K) Shock-resistant according to EN 60721-3-7 Class 7 500 m/s Vibration-resistant according to EN 60721-3-7 200 m/s Class 7 M2 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 268 The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. 7.3.5 Dimension drawing Figure 7-8 RF330T dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 269 Table 7-7 Ordering data RF340T Article number RF340T 6GT2800-4BB00 8 KB FRAM user memory RF340T 6GT2800-5BB00 32 KB FRAM user memory 7.4.3 Mounting on metal Direct mounting of the RF340T on metal is permitted. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 270 Flush-mounting of RF340T in metal: Metal Figure 7-10 Flush-mounting of RF340T in metal The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 271 Vibration-resistant according to EN 60721-3-7 200 m/s Class 7 M2 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (L x W x H) 47.5 x 25 x 15.4 mm Weight 25 g SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 272 ≤ 1.0 Nm Standards, specifications, approvals MTBF 1200 years The values for shock and vibration are maximum values and must not be applied continuously. 7.4.5 Dimension drawing Figure 7-11 Dimension drawing RF340T Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 273 Degree of protection IP68 7.5.2 Ordering data Table 7-9 Ordering data RF350T Article number RF350T 6GT2800-5BD00 7.5.3 Mounting on metal Direct mounting of the RF350T on metal is permitted. Mounting of RF350T on metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 274 The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. 7.5.4 Mounting options Mounting with fixing frame The RF350T transponder can be mounted as shown with the fixing frame: Figure 7-14 Installation diagram SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 275 Write cycles (at < 40 ℃) > 10 Data retention time (at < 40 ℃) > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of RF300 transponders (Page 50)" Mechanical specifications Enclosure SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 276 Weight 25 g Type of mounting 2 x M4 screws ≤ 1.5 Nm Standards, specifications, approvals MTBF 1200 years The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 277 • 8 KB FRAM user memory • 32 KB FRAM user memory Write/read range See section "Field data of RF300 transpond‐ ers (Page 50)" Mounting on metal Yes, with spacer Degree of protection IP67 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 278 This can be achieved using the spacer 6GT2190‑0AA00 in combination with the fixing pocket 6GT2190‑0AB00. Mounting of RF360T on metal Data storage unit Metal Non-metal Figure 7-17 Mounting of RF360T with spacer The standard value for h is ≥ 20 mm. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 279 Data storage unit Metal Non-metal Figure 7-18 Flush-mounting of RF360T with spacer The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 280 RF300 transponder 7.6 SIMATIC RF360T Dimensions of spacer and fixing pocket for RF360T Figure 7-19 Dimensions of spacer and fixing pocket for RF360T SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 281 Vibration-resistant acc. to EN 60721-3-7, Class 7 200 m/s Torsion and bending load Not permitted Design, dimensions and weight Dimensions (L x W x H) 86 x 55 x 2.5 mm Weight 25 g SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 282 6GT2800-4AC00 6GT2800-5AC00 Type of mounting • 2 x M3 screws ≤ 1.0 Nm • Fixing pocket (6GT2190-0AB00) Standards, specifications, approvals MTBF 1200 years 7.6.5 Dimension drawing Figure 7-20 RF360T dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 283 Table 7-14 Ordering data RF370T Article number RF370T 6GT2800-5BE00 32 KB FRAM user memory RF370T 6GT2800-6BE00 64 KB FRAM user memory 7.7.3 Mounting on metal Direct mounting of the RF370T on metal is permitted. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 284 Flush-mounting of RF370T in metal: Figure 7-22 RF370T flush-mounted in metal The standard value for a is ≥ 20 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 285 • -40 … +85 °C • during storage • -40 … +85 °C Degree of protection according to EN 60529 IPx9K Shock-resistant according to EN 60721-3-7 Class 7 500 m/s SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 286 ≤ 1.5 Nm Standards, specifications, approvals MTBF 1200 years The values for shock and vibration are maximum values and must not be applied continuously. 7.7.6 Dimensional drawing Figure 7-23 RF370T dimension drawing Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 287 Universal holder 6GT2590-0QA00 7.8.3 Installation guidelines for RF380T It is essential that you observe the instructions in the Section Installation guidelines (Page 65). The following section only deals with features specific to the SIMATIC RF380T. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 288 A protective cover is recommendable for applications in paint shops. Data memory holder Short version (6GT2 090-0QA00) Long version (6GT2090-0QA00-0AX3) Material: V2A sheet-steel with thickness 2.5 mm BI 2.5 DIN 59382 1.4541 Assembly of data memory with holder SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 289 25 mm. The optional cover can be used for the long and short versions of the holder. Universal holder Figure 7-25 Universal holder 6GT2590-0QA00 7.8.3.2 Metal-free area Direct mounting of the RF380T on metal is permitted. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 290 Flush-mounting of RF380T in metal: Figure 7-27 RF380T flush-mounted in metal The standard value for a is ≥ 40 mm. At lower values, the field data change significantly, resulting in a reduction in the range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 291 Calculation of the temperature curves Calculation of the temperature curves or of a temperature profile can be carried out on request by Siemens AG. Exact knowledge of the internal temperature facilitates configuration for time- critical applications. Ambient temperatures > 110 °C...
  • Page 292 Duration (min) Ambient temperature (°C) Electrolytic dip Electrolytic dip dryer Transport PVC dryer Transport Filler dryer Transport Top coat dryer Transport Wax dryer Transport Figure 7-28 Graphic trend of temperature profile from above table SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 293 Do not clean the transponder with mechanical tools, sand-blasting or pressure hose. These cleaning methods result in damage to the transponder. Clean the transponder only with the chemical cleansing agents listed in Chapter Chemical resistance of the readers and transponders (Page 97). SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 294 Use of the transponder in hazardous areas for gases Temperature class delineation for gases The temperature class of the transponder for hazardous areas depends on the ambient temperature range: Ambient temperature range Temperature class -25 °C to +70 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 295 Write/read distance (S Dependent on the reader used, see section "Field data of RF300 transponders (Page 50)" Mechanical specifications Enclosure • Material • • Color • Anthracite Recommended distance to metal ≥ 0 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 296 Applies only in conjunction with the original support The values for shock and vibration are maximum values and must not be applied continuously. 7.8.8 Dimensional drawing SIEMENS Figure 7-30 Dimension drawing RF380T Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 297 (transmission speed, memory size), however, is considerably less than with RF300 transponders. You will find more information on transmission speeds in the section "Communication between communications module, reader and transponder (Page 49)". The SIMATIC RF300 readers can also describe and read ISO 14443 transponders (MIFARE Classic and MOBY E). SIMATIC RF300...
  • Page 298 Memory configuration of ISO the transponders Figure 8-1 Memory configuration of ISO the transponders Memory areas Depending on the manufacturer of the transponder chip, the memory configuration of an ISO transponder consists of varying sizes of user memory. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 299 The Fujitsu chip MB89R112 (MDS D5xx) has 32 byte blocks and can therefore not be addressed in the OTP area. Note Use of the OTP area is not reversible If you use the OPT area, you cannot undo it, because the OPT area can only be written to once. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 300 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 301 Mounting the MDS D100 / D200 / D400 on metal with spacer Flush-mounting ① Transponder ② Metal ③ Non-metal ≥ 20 mm ≥ 20 mm Figure 8-3 Flush installation of the MDS D100 / D200 / D400 in metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 302 Torsion and bending load ISO 10373 / ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85.6 x 54 x 0.9 mm Weight Type of mounting • Fixing pocket • Glued SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 303 The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. 8.2.5 Dimension drawing Dimensions in mm Dimensions for mounting holes Figure 8-4 MDS D100 dimension drawing SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 304 ISO 15693 Degree of protection IP68/IPx9K 8.3.2 Ordering data Table 8-4 Ordering data for MDS D117 Article number MDS D117 6GT2600-0AG00 Pack of 10 8.3.3 Mounting in metal Flush-mounted in metal ① Transponder ② Metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 305 Shock-resistant acc. to EN 60721-3-7, Class 7M2 1000 m/s Vibration-resistant acc. to EN 60721-3-7, Class 200 m/s Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 4 x 5.2 mm Weight SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 306 Memory size 112 bytes of EEPROM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 307 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal ≥ 15 mm Figure 8-7 Mounting the MDS D124 / D324 / D424 / D524 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 308 D124 can be operated with the readers RF210R, RF220R, RF240R, RF250R (incl. all released antennas), RF260R, RF310R, RF340R, RF350R and RF380R. The MDS D124 transponder is not released for operation with the RF290R reader. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 309 • The device must be mounted on a grounded conductive base. • The device must only be cleaned with a damp cloth. • The device is suitable for use in atmospheres containing dust, but not for full immersion in dust. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 310 -25 ℃ ... +155 ℃ -25 ℃ ... +110 ℃ T180 °C -25 ℃ ... +105 ℃ -25 ℃ ... +60 ℃ T130 °C -25 ℃ ... +80 ℃ T95 °C -25 ℃ ... +55 ℃ T80 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 311 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant according to EN 60721-3-7 Class 1000 m/s Vibration-resistant according to EN 60721-3-7 200 m/s Class 7M3 Torsion and bending load Not permitted SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 312 Manufacturer's address - factory Siemens AG Siemens AG DE – 76181 Karlsruhe, Germany Würzburger Str. 121 DE - 90766 Fürth, Germany 8.4.7 Dimension drawing Figure 8-10 Dimension drawing of MDS D124 All dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 313 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 314 Flush installation of the MDS D126 / D426 / D526 in metal with spacer 8.5.4 Technical specifications Table 8-14 Technical specifications for the MDS D126 6GT2600-0AE00 Product type designation SIMATIC MDS D126 Memory Memory configuration • • 8 bytes SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 315 The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 316 ISO standard ISO 15693 Degree of protection IP68/IPx9K 8.6.2 Ordering data Table 8-15 Ordering data for MDS D127 Article number MDS D127 6GT2600-0AF00 Pack of 10 (A screw-in aid is supplied with each pack) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 317 Damage to the transponder due to improper mounting To screw the MDS D127 into a suitable thread, use the supplied screw-in tool. This avoids damage to the MDS D127. Figure 8-15 Screw-in aid for mounting the MDS D127 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 318 Shock-resistant acc. to EN 60721-3-7, Class 7M2 1000 m/s Vibration-resistant acc. to EN 60721-3-7, Class 200 m/s Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) M6 x 5.8 mm Weight SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 319 228 years The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. 8.6.5 Dimension drawing Figure 8-16 Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 320 IP68/IPx9K Note Compatibility with SIMATIC RF300 depending on the article number The transponder MDS D139 with article number 6GT2600-0AA10 is compatible with the SIMATIC RF300 system. The transponder MDS D139 with article number 6GT2600-0AA00 is not compatible. 8.7.2 Ordering data...
  • Page 321 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal ≥ 30 mm Figure 8-17 Mounting the MDS D139 / D339 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 322 Clean the transponder only with the chemical cleansing agents listed in the section "Chemical resistance of the readers and transponders (Page 97)". When using the transponder in hazardous areas, follow the cleaning instructions in section "Use in hazardous areas (Page 323)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 323 L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 324 Temperature class grading for gases Ambient temperature range Temperature class -25 °C ... +220 °C -25 °C ... +145 °C -25 °C ... +220 °C -25 °C ... +95 °C -25 ℃ ... +30 ℃ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 325 T135 °C -25 °C ≤ T ≤ +40 °C T100 °C 8.7.6 Technical specifications Table 8-21 Technical specifications for MDS D139 6GT2600-0AA10 Product type designation SIMATIC MDS D139 Memory Memory configuration • • 8 bytes SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 326 Vibration-resistant acc. to EN 60721-3-7, Class 7M2 200 m/s Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 85 x 15 mm Weight 50 g Type of mounting 1 x M5 screw 1.5 Nm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 327 For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient). 8.7.7 Dimension drawings Dimensional drawing of MDS D139 Figure 8-19 Dimensional drawing of MDS D139 Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 328 Degree of protection IP68/IPx9K 8.8.2 Information for RF300 compatibility Note Compatibility with SIMATIC RF300 depending on MLFB number Only the MDS D160 with MLFB 6GT2600-0AB10 is compatible with SIMATIC RF300. 8.8.3 Ordering data Table 8-22 Ordering data for MDS D160 Article number...
  • Page 329 • • 8 bytes • User memory • 112 bytes EEPROM • OTP memory • 16 bytes (EEPROM) Read cycles (at < 40 ℃) > 10 Write cycles (at < 40 ℃) > 10 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 330 10 ... 2000 Hz; 3 axes; 2.5 h Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 16 x 3 mm Weight 1.2 g Type of mounting • Patched • Sewn in • Glued SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 331 The regeneration time for the MDS D160 between washing cycles must be at least 24 hours. 8.8.6 Dimension drawings Dimensional drawing of MDS D160 Dimensions in mm Figure 8-21 Dimensional drawing of MDS D160 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 332 Minimum order quantity: 1250 units (5 rolls with 250 units each) 8.9.3 Technical data Table 8-26 Technical specifications for MDS D165 6GT2600-1AB00-0AX0 Product type designation SIMATIC MDS D165 Memory Memory configuration • • 8 bytes • User memory • 112 bytes EEPROM SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 333 Dimensions (L x W x H) 86 x 54 x 0.3 mm Weight Type of mounting Glued with self-adhesive label Standards, specifications, approvals MTBF 228 years The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 334 See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67 8.10.2 Ordering data Table 8-27 Ordering data for MDS D200 Article number MDS D200 6GT2600-1AD00-0AX0 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 335 Mounting on metal ① Transponder ② Metal ③ Non-metal ≥ 20 mm Figure 8-23 Mounting the MDS D100 / D200 / D400 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 336 Write cycles (at < 25 ℃) > 10 Data retention time (at < 25 ℃) > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 337 Fixing pocket • Glued Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 338 See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP65 8.11.2 Ordering data Table 8-30 Ordering data for MDS D261 Article number MDS D261 6GT2600-1AA00-0AX0 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 339 -20 … +85 °C • During transportation and storage • +20 to +30 ℃ Can be stored for 2 years, determined by the dura‐ bility of the adhesive Degree of protection IP65 Design, dimensions and weight SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 340 Type of mounting Glued with self-adhesive label Standards, specifications, approvals MTBF 228 years The processing instructions of the adhesive manufacturer must be observed. 8.11.4 Dimension drawing Dimensions in mm Figure 8-26 Dimension drawing of MDS D261 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 341 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 342 Flush installation of the MDS D124 / D324 / D424 / D524 in metal with spacer 8.12.4 Technical specifications Table 8-34 Technical specifications of MDS D324 6GT2600-3AC00 Product type designation SIMATIC MDS D324 Memory Memory configuration SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 343 The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 344 Memory size 992 bytes of EEPROM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68/IPx9K SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 345 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal ≥ 30 mm Figure 8-30 Mounting the MDS D139 / D339 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 346 Clean the transponder only with the chemical cleansing agents listed in the section "Chemical resistance of the readers and transponders (Page 97)". When using the transponder in hazardous areas, follow the cleaning instructions in section "Use in hazardous areas (Page 347)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 347 L'utilisation de l'appareil près de processus générant de fortes charges est interdite. b) L'appareil doit être monté de manière à être protégé mécaniquement. c) Le montage doit être effectué sur un socle conducteur mis à la terre. d) Nettoyage uniquement avec un chiffon humide. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 348 Temperature class grading for gases Ambient temperature range Temperature class -25 °C ... +220 °C -25 °C ... +145 °C -25 °C ... +220 °C -25 °C ... +95 °C -25 ℃ ... +30 ℃ SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 349 T135 °C -25 °C ≤ T ≤ +40 °C T100 °C 8.13.6 Technical specifications Table 8-39 Technical specifications of MDS D339 6GT2600-3AA10 Product type designation SIMATIC MDS D339 Memory Memory configuration • • 8 bytes SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 350 200 m/s Class 7M3 Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 85 x 15 mm Weight 50 g Type of mounting 1 x M5 screw 1.5 Nm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 351 For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damaging the MDS in high temperatures (expansion coefficient). 8.13.7 Dimensional drawing MDS D339 Figure 8-32 Dimension drawing of the MDS D339 Dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 352 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 353 Mounting the MDS D100 / D200 / D400 on metal with spacer Flush-mounting ① Transponder ② Metal ③ Non-metal ≥ 20 mm ≥ 20 mm Figure 8-34 Flush installation of the MDS D100 / D200 / D400 in metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 354 Torsion and bending load ISO 10373 / ISO 7816-1 Design, dimensions and weight Dimensions (L x W x H) 85 x 54 x 0.8 mm Weight Type of mounting • Fixing lug • Glued SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 355 The values for vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. 8.14.5 Dimension drawing Figure 8-35 Dimensional drawing MDS D400 (dimensions in mm) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 356 Degree of protection IP67/IPx9K 8.15.2 Ordering data Table 8-43 Ordering data of MDS D421 Article number MDS D421 6GT2600-4AE00 8.15.3 Mounting on metal Mounting on metal Figure 8-36 Mounting of MDS D421 / D521 on metal SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 357 • The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities • Apply adhesive according to the manufacturer's processing instructions • Press in transponder by hand, with antenna side outwards (see figure above) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 358 > 10 Data retention time (at < 40 ℃) > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 359 Type of mounting Glued Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 360 ISO 15693 Degree of protection IP68 8.16.2 Ordering data Table 8-45 Ordering data of MDS D422 Article number MDS D422 6GT2600-4AF00 A screw-in aid is included in the scope of supply per packaging unit SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 361 • Flush-mounting of MDS D422 / D522 in metal with tools 8.16.4 Technical specifications Table 8-46 Technical specifications for the MDS D422 6GT2600-4AF00 Product type designation SIMATIC MDS D422 Memory Memory configuration • • 8 bytes • User memory • 2000 bytes FRAM SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 362 ≤ 1 Nm Standards, specifications, approvals MTBF 285 years The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 363 Degree of protection IP68/IPx9K 8.17.2 Ordering data Table 8-47 Ordering data of MDS D423 Article number MDS D423 6GT2600-4AA00 Table 8-48 Ordering data of MDS D423 accessories Article number Fixing hood RF330T / MDS D423 6GT2690-0AE00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 364 Note that if the distance (a) is not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal Figure 8-44 Mounting the MDS D423 on metal Mounting in metal ≥ 10 mm Figure 8-45 Flush-mounting of the MDS D423 in metal clearance SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 365 Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PPS • Color • Black Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 366 Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 367 See section "Field data of ISO transponders (MDS D) (Page 53)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67/IPx9K 8.18.2 Ordering data Table 8-50 Ordering data of MDS D424 Article number MDS D424 6GT2600-4AC00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 368 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal ≥ 15 mm Figure 8-48 Mounting the MDS D124 / D324 / D424 / D524 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 369 Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Epoxy resin • Color • Black Recommended distance to metal ≥ 15 mm Power supply Inductive, without battery SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 370 The processing instructions of the adhesive manufacturer must be observed. ) To prevent it loosening during operation, secure the screw with screw-locking varnish. 8.18.5 Dimension drawing Figure 8-50 Dimension drawing of MDS D424 All dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 371 See section "Field data of ISO transponders (MDS D) (Page 53)". Mounting on metal ISO standard ISO 15693 Degree of protection IP68/IPx9K 8.19.2 Ordering data Table 8-53 Ordering data of MDS D425 Article number MDS D425 6GT2600-4AG00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 372 Data retention time (at < 40 ℃) > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PA 6.6 GF SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 373 Type of mounting 1x transponder set screw M6 SW 22; ≤ 6 Nm Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 374 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 375 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal h ≥ 25 mm Figure 8-53 Mounting the MDS D126 / D426 / D526 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 376 ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 377 The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. 8.20.5 Dimension drawing Dimensions in mm Figure 8-55 Dimension drawing of MDS D426 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 378 See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal ISO standard ISO 15693 Degree of protection IP68/IPx9K 8.21.2 Ordering data Table 8-58 Ordering data of MDS D428 Article number MDS D428 6GT2600-4AK00-0AX0 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 379 Data retention time (at < 40 ℃) > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PA 6.6 GF SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 380 Type of mounting 1x transponder set screw M8 SW 22; ≤ 8 Nm Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 381 Memory size 2000 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67/IPx9K SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 382 Note that if the distance (h) is not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal ① Transponder ② Metal carrier ③ Spacer ≥ 10 mm Figure 8-58 Mounting the MDS D160 / D460 / D560 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 383 Vibration-resistant according to IEC 68-2-6 200 m/s Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 16 x 3 mm Weight Type of mounting • Glued • With spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 384 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal Yes, flush-mounted in metal ISO standard ISO 15693 Degree of protection IP67/IPx9K SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 385 Article number MDS D521 6GT2600-5AE00 8.23.3 Mounting on metal Mounting on metal Figure 8-60 Mounting of MDS D421 / D521 on metal Flush-mounting Figure 8-61 Flush-mounting of MDS D421 / D521 in metal without clearance SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 386 • Remove residues of adhesive • Allow to cure according to the manufacturer's instructions • Flush-mounting of the transponder in metal with tools Installation examples Figure 8-63 Installation example of MDS D421/D521/E623 in a steep cone SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 387 -40 … +100 °C Degree of protection according to EN 60529 • IP67 • IPx9K steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C Shock-resistant acc. to EN 60721-3-7, Class 7M2 1000 m/s SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 388 The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. 8.23.5 Dimension drawing Figure 8-65 Dimension drawing of MDS D521 All dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 389 Units in a package: 10 units A mounting aid is included in the scope of supply per packaging unit. 8.24.3 Mounting in metal Flush-mounting Figure 8-66 Flush-mounting of MDS D422 / D522 in metal without clearance SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 390 Plastic PA 6.6 GF; brass nickel plated • Color • Black/silver Recommended distance to metal ≥ 0 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature • during write/read access • -25 … +85 °C SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 391 The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. 8.24.5 Dimension drawing Figure 8-67 Dimensional drawing of MDS D522 All dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 392 Units in a package: 10 units A mounting aid is included in the scope of supply per packaging unit. 8.25.3 Mounting in metal Flush-mounting Figure 8-68 Flush installation of the MDS D522 special version in metal without clearance SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 393 Make sure that the transponder does not become tilted. Figure 8-69 Dimension drawing: Workpiece drill hole for mounting the MDS D522 special version SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 394 Not permitted Design, dimensions and weight Dimensions (Ø x H) 18 (+0.1) × 5.2 mm Weight Approx. 1.2 g Type of mounting Clipping in once (with accompanying tool) Standards, specifications, approvals MTBF 228 years SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 395 8.25 MDS D522 special variant The values for shock and vibration are maximum values and must not be applied continuously. 8.25.5 Dimensional drawing Figure 8-70 Dimension drawing MDS D522 special version All dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 396 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 397 Flush installation of the MDS D124 / D324 / D424 / D524 in metal with spacer 8.26.4 Technical specifications Table 8-71 Technical specifications for MDS D524 6GT2600-5AC00 Product type designation SIMATIC MDS D524 Memory Memory configuration SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 398 The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. ) To prevent it loosening during operation, secure the screw with screw-locking varnish. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 399 See section "Field data of ISO transponders (MDS D) (Page 53)". Mounting on metal ISO standard ISO 15693 Degree of protection IP68/IPx9K 8.27.2 Ordering data Table 8-72 Ordering data for MDS D525 Article number MDS D525 6GT2600-5AG00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 400 > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PA 6.6 GF • Color • Black SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 401 Type of mounting 1x transponder set screw M6 SW 22; ≤ 6 Nm Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 402 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP68 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 403 Note that if the distances (a and h) are not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal h ≥ 25 mm Figure 8-76 Mounting the MDS D126 / D426 / D526 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 404 ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PA 6.6 GF • Color • Black Recommended distance to metal ≥ 25 mm Power supply Inductive, without battery Permitted ambient conditions Ambient temperature SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 405 The values for shock and vibration are maximum values and must not be applied continuously. ) To prevent it loosening during operation, secure the screw with screw locking varnish. 8.28.5 Dimension drawing Figure 8-78 Dimensional drawing of MDS D526 All dimensions in mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 406 See section "Field data of ISO transponders (MDS D) (Page 53)" Mounting on metal ISO standard ISO 15693 Degree of protection IP68/IPx9K 8.29.2 Ordering data Table 8-77 Ordering data for MDS D528 Article number MDS D528 6GT2600-5AK00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 407 > 10 years Write/read distance (S Dependent on the reader used, see section "Field data of ISO transponders (MDS D) (Page 53)" Mechanical specifications Enclosure • Material • Plastic PA 6.6 GF • Color • Black SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 408 Type of mounting 1x transponder set screw M8 SW 22; ≤ 8 Nm Standards, specifications, approvals MTBF 228 years The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 409 Memory size 8192 bytes of FRAM user memory Write/read range See section "Field data of ISO transponders (MDS D) (Page 53)." Mounting on metal Yes, with spacer ISO standard ISO 15693 Degree of protection IP67/IPx9K SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 410 Note that if the distance (h) is not observed, this may result in a reduction of the field data as well as a reduced write/read range. Mounting on metal ① Transponder ② Metal carrier ③ Spacer ≥ 10 mm Figure 8-81 Mounting the MDS D160 / D460 / D560 on metal with spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 411 Vibration according to IEC 68-2-6 200 m/s Torsion and bending load Not permitted Design, dimensions and weight Dimensions (Ø x H) 16 x 3 mm Weight Type of mounting • Glued • With spacer SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 412 The values for shock and vibration are maximum values and must not be applied continuously. The processing instructions of the adhesive manufacturer must be observed. 8.30.5 Dimension drawings Dimension drawing of MDS D560 Dimensions in mm Figure 8-82 Dimension drawing of MDS D560 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 413 Function blocks are used for integration into the SIMATIC. They are used to transfer the input parameters to the reader using the "init_run" (RESET) command. You will find information on the following blocks on the Internet on the pages of the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14971/man).
  • Page 414 -25 ... +55° C IP67 RF185C/ OPC UA nector socket, M12 allel) RF186C/RF188C RFID 181EIP Ethernet IP 2 x 8-pin connector 2 (parallel) 60 x 210 x 54 mm 0 ... +60° C IP67 socket, M12 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 415 Standard profile V1.19 Ident profile Ident profile Ident blocks SIMATIC RF185C/ FB 45 FB 45 Ident profile RF186C/ FB 55 FB 55 Ident blocks RF188C Standard profile V1.19 Ident profile Ident profile Ident blocks SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 416 Operation in a SIMATIC S7 is controlled by the function block FB 45. ASM 475 and FB 45 form a unit that is used for reading the data of the MDS simply and at optimal speed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 417 Plug-in cable, pre-assembled, length: 2 m (standard length) 6GT2891-0EH20 Plug-in cable, pre-assembled, length: 5 m 6GT2891-0EH50 Terminal element (1 x per reader cable) 6ES7390-5BA00-0AA0 Shield connecting element 6ES7390-5AA00-0AA0 The plug-in cables 6GT2891-4Fxx can be used as extension cables. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 418 24 V are connected to the ASM and the 5 V voltage on the ASM is OK. ACT_1, ACT_2 The corresponding reader is active in processing a user command. ERR_1, ERR_2 A flashing pattern indicates the last error to occur. This display can be reset using the parameter Option_1. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 419 5 Hz Operating system error • Switch ASM off/on 1 flash ev‐ 1 flash ev‐ ASM has booted and is waiting for a RESET ery 2 s ery 2 s (init_run) from the user. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 420 Distributed configuration with ET200M Reader Figure 9-4 Configuration of ASM 475 distributed Reader connection system You will find more information on the reader connector technology in the section "Reader RF3xxR (RS422) with ASM 475 (Page 459)". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 421 9-17 TX + Yellow 1 Reader 2 6-14 RX + Gray 1 Reader 2 4-12 RX - Pink 1 Reader 2 5-13 Shield Cable assignment for connection of an RF300 reader to ASM 475 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 422 • Backplane bus • S7-300 backplane bus • PROFIBUS interface • (according to the head module) • Industrial Ethernet interface • (according to the head module) • Supply voltage • Screw-type or spring-loaded terminals SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 423 Product properties, functions, components general LED display design • 4 LEDs per reader connector • 2 LEDs for device status Product function transponder file handler addressable Protocol supported S7 communication Product functions management, configuration, engineering SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 424 Type of computer-based communication 2 words cyclic, 238 bytes acyclic Transponder addressing Direct access via addresses Commands Initialize transponder, read data from transponder, write data to transponder Standards, specifications, approvals Proof of suitability CE, FCC, UL/CSA SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 425 0x05 0xE6FE0100 Parameter assignment error, possible causes: • Unknown command • Incorrect parameter • Function not allowed 0x06 0xE2FE0100 Air interface faulty 0x0B 0xE1FE0700 The MDS E transponder could not be successfully au‐ thenticated. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 426 Overview Extended diagnostic functions with SIMATIC RF300 SIMATIC RF300 provides extended diagnostics functions with STEP 7 Classic / Basic / Professional, which simplify commissioning and maintenance. As of STEP 7 Basic / Professional V16, the TIA Portal offers the technology object "SIMATIC Ident >...
  • Page 427 Scope of the described UDTs Note that below only the variables are listed that are relevant for the RF300 system. You will find the full UDTs in the manual "Ident Profile and Ident Blocks". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 428 0x00 ... 0xFF = Version (high byte) 0x00 ... 0xFF = Version (low byte) driver char Driver version 3964R 0x31 = 3964R 0x32 = ASCII 0x33 = ASCII/ScanMode 0x34 = RF300 fast protocol (3G) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 429 = 921.6 kBd distance_limiting_SLG byte Note: This parameter is intended for trained users. Siemens rec‐ ommends that untrained users use the default value. The output line can be set in bit 0...3. This setting does not need to be manually performed for RF380R readers of the 2nd gener‐...
  • Page 430 = Operation without presence check and with semaphore pro‐ cedure (RF300, ISO 14443 [MIFARE Classic]) Antenna is switched off. The antenna is only switched on when one of the following commands is sent. Read, Write, Init, Tag- Status SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 431 Faults of this type can be caused by contact problems on the connector or the cable connection. 10.2.3 Transponder diagnostics with "Tag status" (MDS-STATUS) With this command you can query the status and diagnostics data from the transponder currently located in the antenna field. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 432 = Error counter (active) ANWZ byte 0x00 ... 0xFF = Presence counter Note Counter values are deleted. All counter values are deleted when the transponder exits the antenna field or when the antenna is switched off. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 433 = P2P RF350R, 2nd generation 0x44 = P2P RF380R, 2nd generation IC_version byte 0x00 ... 0xFF Chip version size word 0x00 ... 0xFFFF Memory size in bytes depending on transponder type, e.g. MDS D3xx: 992 bytes SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 434 0x00 ... 0xFF Block size of the transponder depending on transponder type, e.g. MDS D3xx: 4 bytes nr_of_blocks byte 0x00 ... 0xFF Number of blocks depending on transponder type, e.g. MDS D3xx: 248 bytes SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 435 The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 436 Declaration of conformity according to the technical regulations of the customs union (TR CU) Brazil (ANATEL) ANATEL-ID: XXXX-YY-ZZZZ Mexico (COFETEL) Mexico (COFETEL) South Africa (ICASA) China (CMIIT) China (CMIIT) CMIIT ID: XXXXYYZZZZ South Korea (KCC) Japan (VCCI) SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 437 Furthermore, the US version has been UL-certified for the US and Canada. Table A-1 Wide-range power supply unit for SIMATIC RF systems Characteristics Area of application Voltage supply for Siemens Ident devices Degree of protection IP67 Design features • Mechanically and electrically rugged design •...
  • Page 438 SIMATIC RF200 / RF300 readers with RS-232 M8 plug at the 24 V end, reader plug angled 24 VDC connecting cable 6GT2891-4KH50-0AX0 for SIMATIC RF200 / RF300 readers with open ends at the power supply unit end SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 439 Failure to observe this requirement shall constitute a revocation of the radio equipment approvals, CE approval and manufacturer's warranty. Furthermore, the compliance to any salient safety specifications of VDE/DIN, IEC, EN, UL and CSA will not be guaranteed. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 440 ① 3. Connect the power cable to the primary input (PE) of the wide-range power supply unit. 4. Connect the power cable of the wide-range power supply unit to the voltage supply. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 441 (e.g. screw and washer M5). Optimum cooling by natural convection must be assured at the mounting location. When used where CSA C22.2 No 107.1-01 applies a separating element must be provided for the output circuit. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 442 Flat washer Cable lug Contact washer: To make ground contact, use contact washers according to the Siemens standard: SN 70093-6-FStflNnnc- 480h, Siemens item no.: H70093-A60-Z3 Degree of protection The wide-range power supply unit for SIMATIC RF systems meets degree of protection IP67.
  • Page 443 < 200 µA leak at U = 230 VAC, f = 50 Hz Mains buffering t ≥ 50 ms at U = 230 VAC Power supply unit classification Level 3 acc. to CSA Mechanical specifications Housing SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 444 Dimensions (L × W × H) • Without plug • 140 × 85 × 35 mm • With plug • 172.7 × 85 × 35 mm Weight 720 g Technical specifications of the input SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 445 ILoad = I1 + I2 Efficiency (%) Remarks U1 = U2 110 VAC 24 VDC No-load protection 110 VAC 24 VDC ≥ 88 220 VAC 24 VDC No-load protection 220 VAC 24 VDC ≥ 90 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 446 Approvals for wide-range power supply unit for SIMATIC RF systems (Europe, UK): 6GT2898-0AC00, 6GT2898-0AC10 Marking Description CE approval acc. to • 2004/108/EG - EMC • 2006/95/EG - Voltage directive Radio approval for Russia, Belarus, Kazakhstan SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 447 • Proper bonding to the end-product main protective earthing termination is: Required • An investigation of the protective bonding terminals has: Been conducted • The following input terminals/connectors must be connected to the end-product supply neutral: Please see chapter "AUTOHOTSPOT". SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 448 • MDS D200 • Mounting: 2 x M4 countersunk screws • MDS D400 • Material: PA6 • Weight: 21 g • Dimensions (L x W x H): 110 x 65 x 5 mm 6GT2390-0AA00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 449 Mounting: 1 x M4 countersunk screw • Tightening torque: ≤ 1 Nm • Material: PA6 • Weight: Approx. 12 g • Remounting cycles: min. 10 • Dimensions (Ø x H): 59 x 30 mm 6GT2690-0AL00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 450 • Material: PPS 6GT2690-0AE00 • Weight: 3 g • Dimensions (L x W x H): 49.4 x 20 x 9.8 mm Dimensional drawings Figure A-2 Dimension drawing of spacer 6GT2190-0AA00 with fixing pocket 6GT2190-0AB00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 451 Appendix A.2 Accessories Figure A-3 Dimension drawing of fixing pocket 6GT2390-0AA00 Figure A-4 Dimension drawing of spacer 6GT2690-0AA00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 452 Appendix A.2 Accessories Figure A-5 Dimension drawing of quick change holder 6GT2690-0AH00 Figure A-6 Dimension drawing of quick change holder 6GT2690-0AH10 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 453 Appendix A.2 Accessories Figure A-7 Dimension drawing of spacer 6GT2690-0AK00 Figure A-8 Dimension drawing of spacer 6GT2690-0AL00 Figure A-9 Dimension drawing of spacer 6GT2690-0AG00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 454 The RF300 readers of the 2nd generation provide the option of simple migration of existing MOBY I systems to SIMATIC RF300. The so-called MOBY I emulation processes frames of the MOBY I protocol on its serial interface and communicates with the established RF300 transponders.
  • Page 455 The operational statuses of the Y-adapter are displayed by four LEDs. The LEDs can adopt the colors yellow and green and the statuses off , on , flashing : Labeling Description ASM TxD No communication module connected to the Y-adapter. (X1) A communication module is connected to the Y-adapter. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 456 Y-adapter to drop below the minimum supply voltage of 20 V. Note Questions on migration If you have questions about migration, please contact the Siemens Industry Online Support (section "Service & Support (Page 473)"). Connecting cable In the following chapter, you will find an overview of the connecting cables between the readers and communication modules or PCs.
  • Page 457 Figure A-12 Connecting cable between ASM 456, RF160C, RF170C, RF180C, RF182C, RF18xC/RF18xCI and RF3xxR reader (RS422) Table A-11 Ordering data Length L Article number 6GT2891-4FH20 6GT2891-4FH50 10 m 6GT2891-4FN10 20 m 6GT2891-4FN20 50 m 6GT2891-4FN50 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 458 38 mm. If you look at the front of the reader, the angled connector always points to the right and runs parallel to the housing. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 459 The connecting cable has a length of 2 m (standard) and 5 m. Extensions up to 1000 m are possible with the 6GT2891-4E… plug-in cables. Figure A-15 Structure of the connecting cable between ASM 475 and RF3xx reader with RS-422 Table A-13 Ordering data Length L Article number 6GT2891-4EH20 6GT2891-4EH50 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 460 Article number 6GT2091-4LH20 6GT2091-4LH50 10 m 6GT2091-4LN10 A.3.4 Reader RF380R (RS232) - PC The connecting cables have a length of 5 m. The outgoing cable for the power supply has a length of 0.5 m. SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 461 Connecting cable between PC and RF380R (RS-232) with open ends for the power supply Table A-15 Ordering data connecting cable Article number Connecting cable with 4-pin power supply connector (5 m) 6GT2891-4KH50 Connecting cable with open ends (5 m) 6GT2891-4KH50-0AX0 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 462 Operating temperature -25 °C ... +70 °C • Dimensions (L x W x H): 75 x 75 x 41 mm • with integrated antenna • ISO 15693 compatible • ISO 14443 (MOBY E) compatible Including ATEX approval 6GT2801-2BA10-0AX2 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 463 Operating temperature: -20 °C ... +55 °C • Dimensions (L x W x H): 250 x 90 x 47 mm • Mobile reader for external antennas, with the option of connecting ANT 8, ANT 12, ANT 18, ANT 30 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 464 3 m 6GT2398-1CA10-0AX0 • Special variant with M8 antenna connector • without antenna connecting cable 6GT2398-1CA20-0AX0 • Special variant with M8 antenna connector • incl. one integrated antenna connecting cable 3 m SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 465 Dimensions (L x W x H): 85.8 x 54.8 x 2.5 mm 6GT2800-5AC00 • Memory size: 32 KB FRAM user memory • Dimensions (L x W x H): 85.8 x 54.8 x 2.5 mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 466 • Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm MDS D339 6GT2600-3AA10 • Memory size: 992 bytes of EEPROM user memory • Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 467 Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8 MDS D560 6GT2600-5AB00 • Memory size: 8192 bytes of FRAM user memory • Dimensions (Ø x H): 16 (±0.2) x 3 (±0.2) mm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 468 I/O interface; max. 4 readers connectable RFID 181EIP Communication module RF181EIP 6GT2002-0JD20 max. 2 readers connectable Connecting block M12, 7/8'' 6GT2002-1JD00 (5-pin) Connecting block M12, 7/8'' 6GT2002-4JD00 (4-pin) Push-pull connecting block, RJ-45 6GT2002-2JD00 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 469 Article number ANT 3 / 3 S / 8 Antenna connecting cable 6GT2391-0AH30 ANT 12 / 18 / 30 M8-180 ↔ M8-90, trailing, 3 m Antenna connecting cable 6GT2391-0AE60 M8-180 ↔ M8-90, trailing, 60 cm SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 470 Industrial Ethernet cable 0.3 m 6XV1870-8AE30 D-coded 0.5 m 6XV1870-8AE50 M12-180 ↔ M12-180 1.0 m 6XV1870-8AH10 1.5 m 6XV1870-8AH15 2.0 m 6XV1870-8AH20 3.0 m 6XV1870-8AH30 5.0 m 6XV1870-8AH50 10 m 6XV1870-8AN10 15 m 6XV1870-8AN15 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 471 ASM 456 / RF160C / 6GT2891-4JH20 RF170C / RF180C 6GT2891-4JH50 and RF3xxR reader 10 m 6GT2891-4JN10 (RS-422) with angled connector ASM 475 6GT2891-4EH20 and reader RF3xxR 6GT2891-4EH50 (RS422) RF120C 6GT2091-4LH20 and reader RF3xxR 6GT2091-4LH50 (RS422) 10 m 6GT2091-4LN10 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 472 2 m US: 6GT2898-0AC20 Connecting cable for wide-range power supply 6GT2091-0PH50 L-coded, 4-pin / A-coded, 4-pin M12-180 ↔ M12-180 M12 connector, 4-pin 6GK1907-0DB10-6AA3 for wide range power supply unit, pack of 3 SIMATIC RF300 System Manual, 02/2021, C79000-G8976-C345-09...
  • Page 473 Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link: (https://support.industry.siemens.com/cs/de/en/) Apart from news, you will also find the following there: •...