Mitsubishi Electric 700 Series Installation Manualline page 27

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Parameter
Name
497
Remote output data 2 0 to 4095
PLC function flash
498
memory clear
503
Maintenance timer
Maintenance timer
504
alarm output set time
Speed setting
505
reference
506
Parameter 1 for user
507
Parameter 2 for user
508
Parameter 3 for user
509
Parameter 4 for user
510
Parameter 5 for user
511
Parameter 6 for user
512
Parameter 7 for user
513
Parameter 8 for user
514
Parameter 9 for user
515
Parameter 10 for user 0 to 65535
S-pattern time at
516
a start of
acceleration
S-pattern time at
517
a completion of
acceleration
S-pattern time at
518
a start of
deceleration
S-pattern time at
519
a completion of
deceleration
Modbus-RTU
539
communication check
time interval
547
Parameter for manufacturer setting. Do not set.
548
Protocol
549
selection
NET mode opera-
550
tion command
source selection
PU mode opera-
551
tion command
source selection
Current average
555
time
Data output mask
556
time
Current average
value monitor
557
signal output ref-
erence current
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Second motor speed
569
control gain
570
Multiple rating setting 2, 102
571
Holding time at a start
Second motor online
574
auto tuning
*1
Setting can be made only when the FR-A7AP/FR-A7AL is mounted.
*2
Parameters cannot be copied from FR-A720 or FR-A740.
Setting Range
Initial Value
0
0 to 9999
0
0 (1 to 9998)
0
0 to 9998, 9999
9999
1 to 120Hz
60Hz
0 to 65535
0
0 to 65535
0
0 to 65535
0
0 to 65535
0
0 to 65535
0
0 to 65535
0
0 to 65535
0
0 to 65535
0
0 to 65535
0
0
0.1 to 2.5s
0.1s
0 to 999.8s,
9999
9999
0, 1
0
0, 1, 9999
9999
1, 2, 3, 9999
2
0.1 to 1.0s
1s
0.0 to 20s
0s
Rated
inverter
0 to 3600A
output
current
(0 to 65535)
0
(0 to 65535)
0
0 to 200%, 9999
9999
2
0.0 to 10.0s,
9999
9999
0, 1
0
Parameter
Name
Output interrup-
575
tion detection
time
Output interrup-
576
tion detection
level
Output interrup-
577
tion cancel level 900 to 1100%
Acceleration time at a
611
restart
Regeneration
665
avoidance frequency
gain
Tuning data unit
684
switchover
Control method
800
selection
Pre-excitation
*1
802
selection
Constant power
range torque
803
characteristic
selection
Torque command
804
source selection
Torque command
805
value (RAM)
Torque command
806
value
(RAM, EEPROM)
807
Speed limit selection
Forward rotation
808
speed limit
Reverse rotation
809
speed limit
Torque limit input
810
method selection 0, 1
Set resolution
811
switchover
Torque limit level
812
(regeneration)
Torque limit level
813
(3rd quadrant)
Torque limit level
814
(4th quadrant)
Torque limit level
815
2
Torque limit level
816
during
acceleration
Torque limit level
817
during
deceleration
Easy gain tuning
818
response level setting 1 to 15
Easy gain tuning
819
selection
820
Speed control P gain 1 0 to 1000%
Speed control integral
821
time 1
822
Speed setting filter 1
Speed detection filter
*1
823
1
Torque control P gain
824
1
Torque control inte-
825
gral time 1
PARAMETER
Setting Range
Initial Value
0 to 3600s, 9999
1s
0 to 400Hz
0Hz
1000%
0 to 3600s, 9999
15s
0 to 200%
100%
0, 1
0
0 to 5, 9 to 12,
20
20
0, 1,
0
0, 1
0
0, 1, 2, 3, 4, 5, 6
0
600 to 1400%
1000%
0, 1, 2
0
0 to 120Hz
60Hz
0 to 120Hz, 999
9999
0
0, 1, 10, 11
0
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
2
0 to 2
0
60%
0 to 20s
0.333s
0 to 5s, 9999
9999
0 to 0.1s
0.001
0 to 200%
100%
0 to 500ms
5ms
22