Battery Replacement; Technical Data - Bosch FERION 3000 O User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
en | Safety
26
6.3

Battery Replacement

If the batteries are flat, the smoke detector will indicate this
with a short beep every 48 seconds and the red LED will also
flash three times every 48 seconds. Replace the batteries as
follows.
Caution!
Do not use 1.2 V batteries.
!
1.
Remove the used batteries from the battery compartments
on the back of the detector head.
2.
Insert three new LR6 batteries (mignon/AA) in the battery
compartments, observing the polarity shown.
Notice!
Once the batteries have been inserted, the red LED flashes ev-
i
ery 48 seconds, which signals that the device is ready for opera-
tion.
7

Technical Data

Sound pressure level at a
distance of 3 m
Power supply
Dimensions (diameter x
height) mm
Protection category
(EN60529)
Permissible operating
temperature
2013.01 | 3.0 | F.01U.249.483
> 85 dB(A)
3 x 1,5 V LR6 Alkaline batteries
(Mignon/AA)
120 x 44 mm
IP30
0 °C to 50 °C