In case more functionality is required, for example, internet access, the dynamic link‑local
addresses cannot be used. In this case the DICENTIS devices and PCs need to be connected
to a DHCP server and gateway to provide internet access. If the DICENTIS Conference System
will become part of a locally present network, contact your local IT department for how to set
up the network.
The DHCP server has to comply with RFC 4676 and must be able to handle 500 requests per
30 seconds. A consumer grade DHCP server as is used in most home router/wireless access
points is not able to comply with this requirement and will cause unexpected and unrequested
behavior.
The DHCP server functionality of Windows server does comply with these requirements.
The DICENTIS Conference System service uses ports 13 and 9710 for communication. Please
make sure that these ports are not used by any other applications on the DICENTIS server
computer.
Notice!
i
How to set up an Ethernet network is outside the scope of this manual.
3.3

Software requirements

For the server PC, DICENTIS requires:
All versions must have the latest service packs and updates installed.
Note: set the Network profile for the Network adapter running the DICENTIS services to
Private (not Public) so that ONVIF cameras can be discovered and to prevent unnecessary
logging.
3.4

License requirements

Before the DICENTIS Conference System can be used, you have to:
1.
2.
Additional licenses can then be purchased to add functionality to the system. See License
overview, page 23 .
3.4.1

License overview

The DICENTIS system has the following types of license:
This section describes the main features of these licenses. For detailed information (including
ordering information), refer to the DICENTIS datasheets on www.boschsecurity.com.
Bosch Security Systems B.V.
Windows Server 2016 (including .NET Framework 3.5 feature), or:
Windows Server 2019 (including .NET Framework 3.5 feature).
Install the DICENTIS System Server Software (DCNM‑LSYS) license on the server PC. See
Installing the DICENTIS software suite, page 29 .
Activate the DICENTIS software.
System license (activates one or more features in the system).
Seat license (activates one or more features in a DICENTIS device).
Service license (keeps the DICENTIS software up-to-date).