Download Print this page
Sealey AK467D Instructions

Sealey AK467D Instructions

Low level oil drainer with pump

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: plEASE REAd THESE INSTRUCTIONS CAREFUllY. NOTE THE SAFE OpERATIONAl REQUIREMENTS, wARNINGS, ANd
CAUTIONS. USE THIS pROdUCT CORRECTlY, ANd wITH CARE FOR THE pURpOSE FOR wHICH IT IS INTENdEd. FAIlURE TO dO SO
MAY CAUSE dAMAGE ANd/OR pERSONAl INJURY ANd wIll INvAlIdATE THE wARRANTY.
1.
SAFETY INSTRUCTIONS
Replace damaged parts. Use recommended parts only.
Unauthorised parts may be dangerous and will invalidate the
warranty.
Keep the drainer clean, dry and in good condition for best and
safest performance.
Wear appropriate protective clothing and eye protection.
If it is necessary to raise the vehicle ensure that it is properly
supported. If the vehicle has been raised with a jack, axle
stands must be put in place before working under the vehicle.
Remove the oil drainer and other tools and equipment from
underneath the vehicle before lowering it again.
Use drainer in a suitable work area. Keep area clean and tidy,
and free from unrelated materials and ensure that there is
adequate lighting.
The work area should have a flat and level surface capable of
supporting the weight of the drainer and it's contents.
DO NOT position the drainer in such a way that it becomes a
hazard to others in the work area.
Ensure that the floor is not slippery and wear non-slip shoes.
Keep children and unauthorised persons away from the work area.
Dispose of waste liquids in accordance with local authority
regulations.
WARNING! DO NOT allow uncontrolled discharge of fluids
which would pollute the environment.
dO NOT use the drainer in wet or damp areas or where
condensation is present.
dO NOT use the drainer near open flames or other sources of
heat.
WARNING! If draining the oil whilst hot, take precautions to
prevent against burns, particularly hands, wrists and arms.
2.
INTROdUCTION & SpECIFICATION
Low level drainer suitable for use on the forecourt and
workshop floor. Steel fabricated unit with a capacity of 64ltr.
Fitted with gravity drain tap for manual discharge (AK467D) or
rotary pump for fast discharge (AK467DXP).
lOw lEvEl OIl dRAINERS
MODELS:
Fully portable with two castors, two fixed wheels and handle for
manoeuvring around the workshop.
Specification:
Capacity: ................................................................................64ltr
Minimum Height to Pan: ...................................................285mm
Maximum Height to Pan: ..................................................285mm
Gravity Feed: .......................................................................... Yes
Suction Probe: ......................................................................... No
Gravity Discharge: .................................................................. Yes
Air Discharge: .......................................................................... No
Pump Discharge: .......................................Yes (AK467DXP only)
3.
ASSEMblY
3.1
Assembly
3.1.1 CASTOR WHEELS. Bolt a castor wheel to each of the
projecting brackets either side of the handle mount using the
M12 nuts and washers provided, as shown above in fig.2.
3.1.2 FIXED WHEELS. Insert the special axle bolts through each
wheel so that the wheel is running on the roller bearing.
Mount each wheel by pushing the axle bolt through each of
the tubular axle mounts welded to the back, bottom edge of
the casing. Secure each axle bolt with the M12 lock nuts
provided. Do not over tighten.
Original Language Version
INSTRUCTIONS FOR:
Ak467d, Ak467dxp
fig.2
AK467D, AK467DXP Issue No.1 09/10/09
fig.1
fig.3

Advertisement

loading

Summary of Contents for Sealey AK467D

  • Page 1 Ak467d, Ak467dxp MODELS: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: plEASE REAd THESE INSTRUCTIONS CAREFUllY. NOTE THE SAFE OpERATIONAl REQUIREMENTS, wARNINGS, ANd CAUTIONS.
  • Page 2  wARNING! dispose of all waste in accordance with local regulations. 4.3.1 GRAVITY DISCHARGE (AK467D) Attach the discharge hose (see fig.1) to the outlet valve at the rear end of the drainer and secure it with the worm drive clip provided. See fig.6.

This manual is also suitable for:

Ak467dxp